• Before installing the Electric Box, please read the following safety precautions carefully to ensure proper installation.
• Observe the following precautions to ensure safety.
• The following symbols are used in this manual to indicate the type and severity of potential consequences that may result when 

given instructions are not followed exactly as stated.

• After the completion of installation, perform a test run to confirm proper operation.
• Retain this manual for future reference. When the unit is reinstalled or repaired, make this manual available to those who provide 

these services. Make sure that the manual is passed on to any future air condition system users. 

1 Safety Precautions

 WARNING

Indicates a risk of death or serious injury.

 CAUTION

Indicates a risk of injury or damage to the product.

 WARNING

 CAUTION

Air-conditioner Network System Optional Parts
Electric Box for AG-150A

PAC-YG83UTB

Installation Manual

Applicable 
Model

Centralized Controller

AG-150A

Only a dealer or qualified technician should replace 
the unit. 

Improper replacement by an unqualified person may result 
in electric shock or fire.

The Electric Box should be installed on a surface that 
is strong enough to support the weight of the unit.

If the Electric Box is installed on a surface that lacks the 
strength to support it, it may fall and cause injury.

Do not attempt to modify or repair the Electric Box.

Modification or improper repair may result in electric shock 
or fire. Consult your dealer when repairs are necessary.

Install the Electric Box properly according to the 
instructions detailed in this Installation Manual.

Improper installation by an unqualified person may result in 
electric shock or fire.

Electric work must be performed by authorized 
personnel according to the local regulations and the 
instructions detailed in the Installation Manual.

Inadequate circuit capacity or improper installation may 
result in electric shock or fire.

Ask your dealer or an authorized technician to move 
the Electric Box. 

Improper installation by an unqualified person may result in 
electric shock or fire. Consult your dealer or a qualified 
technician.

Do not install the Electric Box where there is a risk of 
leaking flammable gas.

If the leaked gas accumulates around the Electric Box, it 
may ignite and cause an explosion.

Do not use the Electric Box in an environment that has 
high concentrations of oil, steam, or sulfuric gas.

These substances may have adverse effects on the 
performance of the Electric Box or damage its parts.

Seal the wire access holes with putty to prevent dew, 
water, and insects from entering to avoid electric 
shock.

Do not install this Electric Box in a place that has the 
potential for steam, such as a bathroom or kitchen. 

Steam may cause an electric shock or a unit malfunction.

Do not install this Electric Box where an acid, alkaline 
solution, or special chemical spray is used frequently 
to avoid electric shock or malfunction.

Keep the cables from coming in direct contact with the 
edges of the wire access holes. 

If the cables are damaged, they may cause electric shock 
or fire.

This Electric Box is for exclusive use with the AG-150A 
and cannot be used with other devices.

Summary of Contents for PAC-YG83UTB

Page 1: ...irs are necessary Install the Electric Box properly according to the instructions detailed in this Installation Manual Improper installation by an unqualified person may result in electric shock or fire Electric work must be performed by authorized personnel according to the local regulations and the instructions detailed in the Installation Manual Inadequate circuit capacity or improper installat...

Page 2: ...led on a non wood surface select an appropriate type of screws 4 pcs to suit the structure type Check that the wall is strong enough to support the weight of the Electric Box PAC YG83UTB 2 0 kg ø21 5 7 8 ø27 1 1 1 8 ø27 1 1 1 8 ø27 1 1 1 8 ø34 1 6 17 ø27 1 1 1 8 ø21 5 7 8 ø34 1 6 17 346 13 5 8 278 11 250 9 7 8 200 7 7 8 M4 ø6 2 9 163 6 7 16 167 6 5 8 102 4 1 16 15 5 8 60 2 3 8 30 1 3 16 51 2 1 16 ...

Page 3: ... behind the wall A minimum space of 60 mm 2 3 8 in is required behind the wall 4 Selecting an Installation Site 185 7 5 16 300 11 13 16 127 5 102 5 4 1 16 7 5 16 17 5 3 4 Electric Box size PAC YG83UTB Centralized controller AG 150A size Unit mm in Inside wall Electric Box PAC YG83UTB 60 mm 2 3 8 in minimum Building structure posts etc Centralized controller AG 150A ...

Page 4: ...c Box to a post or other building structure Select an appropriate type of screws 4 pcs to suit the structure type Check that the wall is strong enough to support the weight of the Electric Box 2 Punch out the knockout holes Punch out appropriate knockout holes depending on how the cables are routed 5 Installation CAUTION Keep the cables from coming in direct contact with the edges of the wire acce...

Page 5: ...roper installation of the AG 150A 4 Installing the installation plate The A type installation plate supplied with AG 150A installed by first fitting it in the wall opening then attaching it to the Electric Box 1 Fit the A type installation plate in the wall opening 278 11 152 6 Size of the opening Cut a hole along the edges of the opening Unit mm in A type installation plate supplied with the AG 1...

Page 6: ...ut in as shown in Step 3 above the screw holes on the A type installation plate will automatically be aligned with the screw holes on the Electric Box M4 flathead screws supplied with AG 150A Mounting holes for the A type installation plate Wall NOTE Drilling prepared holes ø3 on the walls will make it easier to screw in the screws Drill appropriate prepared holes according to the wall material ...

Page 7: ...wn below the connector before connecting it to the terminal block or connector as shown in the figure below to prevent water from running down the cable and cause electric shock or fire Insert a flat tip screwdriver in the holes indicated and move the handle up to remove the cover Terminal block or connector Good example Bad example Wall DC Power cable M NET transmission cable M NET transmission c...

Page 8: ... Installing the AG 150A Install the AG 150A with the four M4 round head screws on the A type installation plate 9 Replace the AG 150A surface cover Conduit Electric box Bushing M NET transmission cable or DC power cable Lock nut Wall Line lead in port Seal with putty M4 rounded screw supplied with AG 150A A type installation plate Wall ...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN Authorized representative in EU MITSUBISHI ELECTRIC EUROPE B V HARMAN HOUSE 1 GEORGE STREET UXBRIDGE MIDDLESEX UB8 1QQ U K WT05420X01 Printed in Japan Recycled Paper ...

Reviews: