- 17 -
-JPEG Settings
Sets up the creation condition, screen size, color and name of JPEG file to be sent to
FTP.
Pre event: Creates the JPEG file of chapter 1~5 for 1~2 seconds before the event is
generated.
Post event: Creates the JPEG file of chapter 1~15 for 1~2 seconds after the event is
generated.
Image size: Selects the size of JPEG file to be created among 160X120 and 320X240.
Color: Selects the color or B&W of JPEG file to be created.
Base Name: Write in the basic name of file to be created.
Except for the basic name, It is possible to add supplementary names for discriminating
multiple files.
Additional suffix: Selects one among date, time and the number of sequence created.
~
None: Do not add supplementary names.
~
Date Time: Adds the date and time when the file was created behind the basic name.
~
Sequence: Adds the number in sequence of file creation behind the basic name.
z
Event Setup
It is possible to select and operate, from Alarm of Alarm OUT and eMail, the Motion
Event occurred from each of the 4 channels & Quad screen and the Event occurred
from Alarm in port 1 to 2.
IN-OUT Mapping
By connecting the Alarm OUT operations to the events occurred from the Alarm IN,
users can send an eMail or text message.
Alarm IN - Alarm IN comes in Motion, Alarm in port 1 and Alarm in port 2.
Alarm OUT
Alarm: Operate the equipment connected to the Alarm OUT port to the events
occurred from the Alarm IN.
eMail: Send an email to events occurred from the Alarm IN.
FTP: S
ends the captured picture to FTP by the event which occurs from Alarm
input.
□
Enable mandatory alarm out: Enable alarm control to open/close contact.
Summary of Contents for NM-VS100
Page 1: ......