
70
SW2 setting
Display detail
Explanation for display
Unit
:
Indoor pipe temperature / Liquid on
error occurring
– 39~88
– 39~88
(When the temperature is 0°C or less, “–” and
temperature are displayed by turns.)
(Example)
When –15°C; 0.5 secs. 0.5secs. 2 secs.
Indoor pipe temperature / Cond./ Eva. on
error occurring
– 39~88
– 39~88
(When the temperature is 0°C or less, “–” and
temperature are displayed by turns.)
(Example)
When –15°C; 0.5 secs. 0.5secs. 2 secs.
Outdoor pipe temperature / 2-phase
(TH6) on error occurring
– 39~88
– 39~88
(When the temperature is 0°C or less, “–” and
temperature are displayed by turns.)
(Example)
When –15°C; 0.5 secs. 0.5secs. 2 secs.
Outdoor outside temperature (TH7) on
error occurring
– 39~88
– 39~88
(When the temperature is 0°C or less, “–” and
temperature are displayed by turns.)
(Example)
When –15°C; 0.5 secs. 0.5secs. 2 secs.
Outdoor heatsink temperature (TH8) on
error occurring
– 40~200
– 40~200
(When the temperature is 0°C or less, “–” and
temperature are displayed by turns.)
(When the temperature is 100°C or more, hundreds
digit, tens digit and ones digit are displayed by turns.)
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
15
15
15
15
:
:
:
:
Indoor unit 1
Indoor unit 2
Indoor unit 3
Indoor unit 4
Indoor unit 5
Indoor unit 6
Indoor unit 7
Indoor unit 8
0
1
0
1
0
1
0
1
0
0
1
1
0
0
1
1
0
0
0
0
1
1
1
1
SW1
6
5
4
Indoor unit 1
Indoor unit 2
Indoor unit 3
Indoor unit 4
Indoor unit 5
Indoor unit 6
Indoor unit 7
Indoor unit 8
0
1
0
1
0
1
0
1
0
0
1
1
0
0
1
1
0
0
0
0
1
1
1
1
SW1
6
5
4
:
0~255
(When the temperature is 100°C or more, hundreds
digit, tens digit and ones digit are displayed by
turns.)
(Example)
When 150°C; 0.5 secs. 0.5secs. 2 secs.
Sub-cool on error occurring. SC
0~130
0~130
(When the temperature is 100°C or more, hundreds
digit, tens digit and ones digit are displayed by
turns.)
(Example)
When 115°C; 0.5 secs. 0.5secs. 2 secs.
50
1
1
ON
2 3 4 5 6
Discharge superheat on error occurring
SHd
0~255
1
ON
2 3 4 5 6
:
15
1
Summary of Contents for MXZ-8B48NA
Page 87: ...87 ...