2-1. INSTALLING THE UNIT

Fix here with 
M10 bolts.

Make the setting 
depth deeper.

Make width wider.

Anchor leg

25 or less

Anchor bolt length

Anchor bolt pitch

(Unit: mm)

2-2. CONNECTING WIRES FOR OUTDOOR UNIT

Terminal block  
for power supply

•  Be sure to fix the unit’s legs with bolts when installing it.

•  Be sure to install the unit firmly to ensure that it does not fall by an earthquake or a gust.

•  Refer to the figure in the right for concrete foundation.

•  Do not use the drain socket and the drain caps in the cold region.
 

Drain may freeze and it makes the fan stop.

•  Remove the tape on the panel when opening the package. (DO NOT remove the LABELS on the panel.)

1) Remove the service panel.
2)  Loosen terminal screw, and connect indoor/outdoor unit connecting wire 

(B) from the indoor unit correctly on the terminal block. Be careful not 
to make mis-wiring. Fix the wire to the terminal block securely so that 
no part of its core is appeared, and no external force is conveyed to the 
connecting section of the terminal block. 

3) Firmly tighten the terminal screws to prevent them from loosening. After 

tightening, pull the wires lightly to confirm that they do not move.

4) Perform 2) and 3) for each indoor unit.
5) Connect power supply cord (A).
6) Fix indoor/outdoor unit connecting wire (B) and power supply cord (A) 

with the cable clamps.

7) Close the service panel securely. Make sure that 3-2. PIPE CONNEC-

TION is completed.
• After making connections between both power supply cord (A) and 

indoor/outdoor unit connecting wire (B), be sure to fix both cable and 

wire with cable clamps.

Connecting order
•  Connect the terminal block in 

following order.

 A

B

C

D

E

F

P

DR

Terminal block for indoor/outdoor unit

Cable clamps

600

370

Service panel

Screws

Note:

•  Removing the handle increases the effectiveness of the wiring operation.
•  Be sure to reinstall the handle.

2.  OUTDOOR UNIT INSTALLATION

Terminal block  
for DRED Interface

DRED Interface

Power supply

35 mm

15 mm

Lead wire

•  Be sure to attach each screw to its correspondent 

terminal when securing the cord and/or the wire to 
the terminal block.

•  Make earth wire a little longer than others.
     (More than 35 mm)
•  For future servicing, give extra length to the con-

necting wires.

1   2   3   C

<OUTDOOR UNIT>

Indoor/outdoor unit 
connecting wire

<INDOOR UNIT>

Terminal block

Terminal block

Terminal block

Terminal block for 
power supply

Terminal block

<INDOOR UNIT>

POWER SUPPLY
~/N 230 V 50 Hz

This unit has demand response capability which is compliant with AS/NZS 4755.3.1. To activate this function, you need to make a contract with remote 
agents such as electric supply company, then this unit should be connected to Demand response enabling devise (DRED). For further information, 
consult your dealer. This unit supports 3 Demand Response Modes (DRMs): DRM1, DRM2 and DRM3.

 CAUTION

• To prevent malfunction caused by noise, route the cord connecting this unit to DRED and the power supply cord as parallel as possible.
• Do not connect the demand control transmission cable to the terminal block for power supply.
• Do not pull, extremely bend or apply strong pressure on the wire to prevent failure.
• Do not screw DRED to outdoor unit.
• Do not put DRED in outdoor unit.
• Secure electrical wiring above clamp. 
• Do not get DRED wire caught in the service panel.

1 : DRM 1
2 : DRM 2
3 : DRM 3
C : COMMON

AS/NZS4755 
terminal block

Summary of Contents for MXZ-6E120VAD2

Page 1: ... Air Conditioner MXZ 6E120VAD2 English Installation Manual For INSTALLER This manual only describes the installation of outdoor unit When installing the indoor unit refer to the installation manual of indoor unit ...

Page 2: ...e intermediate connection Incomplete connecting and securing could cause fire n Do not install the unit in a place where inflammable gas may leak If gas leaks and accumulates in the area around the unit it could cause an explosion n Do not use intermediate connection of the power cord or the extension cord and do not connect many devices to one AC outlet It could cause a fire or an electric shock ...

Page 3: ...ecommended to install a baffle board on the air outlet side of the outdoor unit Avoid the following places for installation where air conditioner trouble is liable to occur Where flammable gas could leak Where there is much machine oil Salty places such as the seaside Where sulfide gas is generated such as hot spring sewage waste water Where there is high frequency or wireless equipment Where ther...

Page 4: ...lt M10 370 mm 417 mm When the piping is to be attached to a wall containing metals tin plated or metal netting use a chemically treated wooden piece 20 mm or thicker between the wall and the piping or wrap 7 to 8 turns of insula tion vinyl tape around the piping To use existing piping perform COOL operation for 30 minutes and pump down before removing the old air conditioner Remake flare according...

Page 5: ...e sure to fix both cable and wire with cable clamps Connecting order Connect the terminal block in following order A B C D E F P DR Terminal block for indoor outdoor unit Cable clamps 600 370 Service panel Screws Note Removing the handle increases the effectiveness of the wiring operation Be sure to reinstall the handle 2 OUTDOOR UNIT INSTALLATION Terminal block for DRED Interface DRED Interface P...

Page 6: ...ith Fig 6 If flare is noted to be defective cut off the flared section and do flaring work again WARNING When installing the unit securely connect the refrigerant pipes before starting the compressor CAUTION When there are the ports which are not used make sure their nuts are tightened securely 4 1 PURGING PROCEDURES AND LEAK TEST 1 Remove service port cap of stop valve on the side of the outdoor ...

Page 7: ...eration mode 1 Be sure to turn off the main power for the air conditioner before making the setting 2 Set the 3 of SW1 on the outdoor controller board to ON to enable this function 3 To lock the operation mode in COOL DRY mode set the 4 of SW1 on the outdoor controller board to OFF To lock the operation in HEAT mode set the same switch to ON 4 Turn on the main power for the air conditioner Descrip...

Page 8: ...event electronic control P C board damage make sure to perform static elimination before operating this function This function does not operate when the outside temperature is 0 C or below LED indication during detection LED1 Red LED2 Yellow LED3 Green Lit Lit Once Result of piping wiring correction function LED1 Red LED2 Yellow LED3 Green Result Lit Not lit Lit Completed Problem corrected or norm...

Page 9: ...blank indd 15 2017 10 31 10 24 48 ...

Page 10: ...blank indd 16 2017 10 31 10 24 48 ...

Page 11: ...blank indd 17 2017 10 31 10 24 48 ...

Page 12: ...VH79B003H01 HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN ...

Reviews: