Sp-5

Fig. 1

Fig. 2

Fig. 3

Fig. 4

Fig. 5

Fig. 6

Di metro del tubo 

[pulg. (mm)]

B

[pulg. (mm)]

A [pulg. (mm)]

Par de torsi n

Herramienta tipo em

-

brague para R410A

Herramienta tipo em

-

brague para R22

Herramienta tipo tuerca 

de mariposa para R22

pies-Ib

N•m

kgf•cm

1/4 ( 6,35)

21/32 (17)

0 a 0,02

(0 a 0,5)

0,04 a 0,06

(1,0 a 1,5)

0,06 a 0,08

(1,5 a 2,0)

10 a 13

13,7 a 17,7

140 a 180

3/8 ( 9,52)

7/8 (22)

25 a 30

34,3 a 41,2

350 a 420

1/2 ( 12,7)

1-1/32 (26)

0,08 a 1,0

(2,0 a 2,5)

36 a 42

49,0 a 56,4

500 a 575

5/8 ( 15,88)

1-5/32 (29)

54 a 58

73,5 a 78,4

750 a 800

Si quedan puertos sin utilizar, ase-

gú rese de apretar firmemente sus 

tuercas.

4-1. PROCEDIMIENTO DE PURGADO   PRUEBA DE FUGAS

3.  TRABAJOS DE ABOCARDADO Y CONEXIÓ N DE TUBERÍ AS

3-1. TAREAS DE ABOCARDAMIENTO

3-2. CONEXIÓ N DE TUBERÍ AS

1) Aplique una capa fina de aceite refrigerante (G) a los extremos abocardados de 

las conexiones de la tuber a de la unidad exterior.

2) Alinee el centro de la tuber a con el centro de las conexiones de la tuber a de la 

unidad exterior y apriete a mano las primeras 3 o 4 vueltas de la tuerca abocar

-

dada.

3) Apriete la tuerca abocardada con una llave dinamométrica tal y como se especifica 

en la tabla.

•  Si la aprieta demasiado podr a da arse la tuerca abocardada, causando pérdidas 

de refrigerante.

•  No olvide envolver las tuber as con cinta aislante. El contacto directo con la 

tuber a descubierta podr a causar quemaduras o congelaci n.

3-3. AISLAMIENTO TÉRMICO Y FORRADO CON CINTA

1) Cubra las uniones de tuber as con cubiertas de tuber a.

2) En el lado de la unidad exterior, a sle bien cada una de las tuber as y v lvulas.

3) Aplique cinta de tuber as (E) a partir de la entrada de la unidad exterior.

•  Sujete con cinta (adhesiva) el extremo de la cinta de tuber as (E).

•  Cuando  las  tuber as  deban  colocarse  por  encima  del  techo,  en  un  armario 

empotrado o en lugares con una temperatura y humedad elevadas, tendr  que 

aplicar una cantidad suplementaria de aislante para evitar la condensaci n.

4.  PROCEDIMIENTOS DE PURGADO, PRUEBA DE FUGAS   FUNCIONAMIENTO DE PRUEBA

1) Corte el tubo de cobre correctamente con un cortador 

de tubos. (Fig. 1, 2)

2) Elimine completamente las rebabas del corte transversal 

del tubo. (Fig. 3)

•  Oriente la tuber a de cobre hacia abajo para evitar que 

las rebabas caigan dentro de la misma.

3) Una vez eliminadas las rebabas, extraiga las tuercas 

abocardadas colocadas en las unidades interior y exte

-

rior y p ngalas en el tubo. (Cuando se ha terminado el 

proceso de abocardado ya no se pueden poner).

4) Labores de abocardamiento (Fig. 4, 5). Sujete firmemen

-

te el tubo de cobre de la dimensi n que se muestra en 

la tabla. Seleccione la medida A pulg. (mm) en la tabla 

de acuerdo con la herramienta seleccionada.

5) Compruebe 

•  Compare el abocardado con la Fig. 6.

•  Si el abocardado se ve defectuoso, corte la secci n 

abocardada y repita el proceso de abocardado.

1) Retire la tapa de la abertura de servicio de la v lvula de retenci n situada en 

el lado de la tuber a de gas de la unidad exterior. (Inicialmente, las v lvulas 

de retenci n est n completamente cerradas y cubiertas con sus tapas).

2) Conecte la v lvula colectora de man metro y la bomba de vac o al puerto 

de servicio de la v lvula de retenci n en el lado de la tuber a del gas de la 

unidad exterior.

3) Ponga en funcionamiento la bomba de vac o. (Déjela funcionar durante m s 

de 15 minutos).

4) Compruebe el vac o con la v lvula colectora de man metro, cierre luego 

esta v lvula y detenga la bomba de vac o.

5) Espere as  uno o dos minutos. Aseg rese de que el indicador de la v lvula 

colectora de man metro permanece en la misma posici n. Compruebe que 

el man metro de presi n marca -14,7 psi [man metro] (-0,101 MPa).

6) Extraiga r pidamente la v lvula colectora de man metro del puerto de servicio 

de la v lvula de retenci n.

7) Abra por completo todas las v lvulas de retenci n de la tuber a de gas y de la 

tuber a de l quido. Si no se lleva a cabo esta operaci n abriendo dichas v l

-

vulas por completo, el rendimiento disminuir  y se producir n problemas.

8) Consulte  1-2.,  e  introduzca  la  cantidad  indicada  de  refrigerante  si  fuera 

necesario.  Introduzca  el  refrigerante  l quido  con  lentitud.  De  lo  contrario, 

la composici n del refrigerante en el sistema puede cambiar y afectar al 

rendimiento del equipo de aire acondicionado.

9) Apriete la tapa del puerto de servicio para volver al estado inicial.

10)

 

Prueba de fugas

Inclinado Irregular Con 

                              rebabas

Bien

Mal

Rebaba

Tuber a de cobre

Escariador de reserva

Cortador 

de tuber as

Reborde liso

Reborde de  

longitud uniforme

Interior 

lustroso sin 

ara azos.

Tuerca  

abocardada

Pieza de 

fijaci n

Tuber a de 

cobre

Tipo manguito 

de embrague

Abocardador

Tipo tuerca de 

aletas

Tuber a 

de cobre

Al instalar la unidad, conecte las tube-

r as de refrigerante de forma fija antes 

de poner en marcha el compresor.

 ATENCIÓN

 CUIDADO

B

Tapa de la abertura 

de servicio

(Par 13,7 a 17,7 N•m, 

140 a 180 kgf•cm)

V lvula de  

retenci n para  

GAS

Tapa de la v lvula de 

retenci n

(Par 19,6 a 29,4 N•m, 

200 a 300 kgf•cm)

V lvula colectora 

de man metro 

(para R410A)

Indicador de presi n  

compuesto (para R410A)

0,101 MPa  

( 760 mmHg)

Manivela 

hacia  

abajo

Manivela 

hacia arriba

Bomba de vac o 

(para R410A)

Manguera de carga 

(para R410A)

*Cerrado

*Abierta

Llave hexagonal

*4 a 5 vueltas

V lvula de 

retenci n para 

L QUIDO

Man metro

(para R410A)

Precauciones al utilizar 

la v lvula de control

Al conectar la v lvula de control al 

puerto de servicio, la pieza interior 

de la v lvula podr a deformarse o 

soltarse  si  se  aplica  demasiada 

presi n.  Esto  podr a  provocar 

fugas de gas.

Puerto de 

servicio

Manguera 

de carga 

(para 

R410A)

Cuerpo

Cerrado

Abierta

V lvula 

de control

A

Al conectar la v lvula de control al 

puerto de servicio, aseg rese de 

que la pieza interior de la v lvula 

est   cerrada,  y  a  continuaci n 

apriete  la  pieza A.  No  apriete  la 

pieza A  ni  gire  la  pieza  interior 

cuando esté abierta la v lvula.

BH79A325H02_es.indd   5

2018/03/05   16:58:31

Summary of Contents for MXZ -2C20 NA2

Page 1: ... Lors de l installation de l appareil intérieur consultez la notice d installation de cet appareil Toute altération structurelle requise pour l installation doit être conforme aux exi gences du code du bâtiment local Manual de instalació n Para el I NSTALADOR E n este manual só lo se describe la instalació n de la unidad exterior Para instalar la unidad interior consulte el manual de instalació n ...

Page 2: ...lug or the outlet it could cause electric shock or fire If loose parts are found on the po er supply plug replace it Securely attach the electrical cover to the indoor unit and the service panel to the outdoor unit If the electrical cover of the indoor unit and or the service panel of the outdoor unit are not attached securely dust w ater etc could collect in the unit and could cause a fire or an ...

Page 3: ... ing only When there is an obstacle in front of the unit as sho n in the figure open space above behind and on the sides of the unit is required 2 Front blow ing side open As long as space indicated in the figure is provided it is allo ed to install the unit w here obstacles are behind and on the sides of the unit No obstacle above the unit FREE SPACE REQUIRED AROUND OUTDOOR UNIT Service space Whe...

Page 4: ...ore than 7 7 8 in 200 mm if there are obstacles to both sides Open as a rule More than 19 11 16 in 500 mm if the back both sides and top are open More than 13 25 32 in 350 mm Outdoor unit installation Air inlet Air outlet 2 U shape notched holes Base bolt M8 2 U shape notched holes Base bolt M8 Unit inch 2 1 INSTALLING THE UNIT Fix here w ith M8 bolts Make the foundation deeper Make the foundation...

Page 5: ...Min AWG14 or stranded conductor Min AWG14 Use double insulated copper ire ith 600 V insulation Use copper conductors only Follow local electrical code POW ER SUPPLY CABLE Use solid or stranded conductor Min AWG8 Use copper conductors only Follow local electrical code GROUND W IRE Use solid or stranded conductor Min AWG8 Use copper conductors only Follow local electrical code W ARNING Use the indoo...

Page 6: ...ompleted burr removal Not possible to put them on after flaring ork 4 Flaring ork Fig 4 5 Firmly hold copper pipe in the dimension show n in the table Select A inch mm from the table according to the tool selected 5 Check Compare the flared ork ith Fig 6 If flare is noted to be defective cut off the flared section and do flaring ork again 4 1 PURGING PROCEDURES AND LEA TEST 1 Remove service port c...

Page 7: ... Note Make sure to fix the maintenance panel securely Incomplete installation could cause malfunction Maintenance panel 4 4 LOC ING THE OPERATION MODE OF THE AIR CONDITIONER COOL DR HEAT 4 5 LO ERING THE OPERATION NOISE OF THE OUTDOOR UNIT Description of the function With this function once the operation mode is locked to either COOL DRY mode or HEAT mode the air conditioner operates in that mode ...

Page 8: ...there is possibility of incorrect w iring and piping combination and confirming the combination is difficult use this function to detect and correct the combination by follo ing the procedures belo Make sure that the follo ing is done Po er is supplied to the unit Stop valves are open Note During detection the operation of the indoor unit is controlled by the outdoor unit During detection the indo...

Page 9: ...entation dans la prise secteur La présence de poussière de saleté ou d éléments desserrés sur la fiche d alimentation ou la prise secteur peut entraîner un choc électrique ou un incendie Remplacez les éventuels éléments desserrés Fixez correctement le couvercle du boîtier électrique de l unité interne et le panneau de service de l unité externe Si le couvercle du boîtier électrique de l unité inte...

Page 10: ...ez jamais l unité externe dans un endroit où le côté présentant l entrée la sortie d air risque d être directement exposé au vent Pour protéger l unité externe du vent installez la de façon à ce que l entrée d air soit face au mur Pour éviter toute exposition au vent il est recommandé d installer un écran de protection du côté de la sortie d air de l unité externe Pour éviter tout problème de fonc...

Page 11: ...EFROI DISSEMENT de 30 minutes et lan cer l aspiration avant de procéder à la dépose de l ancien climatiseur Reformer l écrou évasé en respec tant les dimensions des nouveaux tuyaux de réfrigérant Fixer ici avec des boulons M8 Augmenter la profondeur des fondations Augmenter la largeur des fondations 2 INSTALLATION DE L APPAREIL EXTÉRIEUR 2 1 INSTALLATION DE L APPAREIL S assurer de bien attacher le...

Page 12: ...Utiliser des conducteurs en cuivre uniquement Respecter le code électrique local AVERTISSEMENT Utiliser le câble de connexion conforme aux normes techniques pour raccorder les unités interne et externe et fixer le câble fer mement sur la bloc de sortie de façon que le côté raccordement de ce dernier ne soit soumis à aucune contrainte extérieure Un raccordement incomplet ou une fixation incorrecte ...

Page 13: ...ez le bouchon de l ouverture de service pour recréer les conditions d origine 10 Test de contrôle des fuites 3 2 RACCORDEMENT DES TUYAUX 1 Appliquez une fine couche d huile réfrigérante G sur les embouts évasés des tuyaux ainsi que sur les raccords de tuyau de l appareil extérieur 2 Alignez la partie médiane du tuyau sur les raccords de tuyau de l appareil extérieur et serrez les écrous évasés à l...

Page 14: ...ement le panneau d entretien Une installation incomplète risque rait de provoquer un dysfonctionnement 4 4 VERROUILLAGE DU MODE DE FONCTIONNEMENT DU CLIMATISEUR REFROIDISSEMENT DÉSHUMIDIFICATION CHAUFFAGE 4 5 RÉDUCTION DU BRUIT DE FONCTIONNEMENT DE L APPAREIL EXTÉRIEUR Description de la fonction Lorsque cette fonction est sélectionnée si le mode de fonctionnement est blo qué sur COOL DRY REFROIDIS...

Page 15: ...de Lorsque le compresseur s arrête le dispositif de protection contre la remise en marche à trop brève échéance s enclenche Le compresseur restera arrêté trois minutes avant de se remettre en marche afin de protéger le climatiseur Fonction de correction de câblage tuyauterie L appareil est équipé d une fonction qui permet de corriger les branchements de câblage et de tuyauterie En cas de brancheme...

Page 16: ... unidad interior y el panel de servicio a la unidad exterior Si no se fijan con firmeza la cubierta de instalaci n eléctrica de la unidad interior y el panel de servicio de la unidad exterior podr a acumularse polvo agua etc en la unidad y producirse un incendio o una descarga eléctrica Al instalar reubicar o reparar la unidad asegú rese de que en el circuito de refrigeració n no entra ninguna otr...

Page 17: ...No instale nunca la unidad exterior en un lugar en el que el lado de entrada salida de aire quede expuesto directamente al viento Para evitar la exposici n al viento instale la unidad exterior con el lado de entrada de aire hacia la pared Para evitar la exposici n al viento se recomienda instalar una placa de flectora en el lado de salida de aire de la unidad exterior Para instalar el aparato de a...

Page 18: ...entes active el modo COOL REFRIGERA CI N durante 30 minutos y realice el bombeo de vaciado antes de retirar el acondicionador de aire antiguo Adapte el abocardado a las dimensiones para el nuevo refrigerante 2 1 INSTALACIÓ N DE LA UNIDAD Aseg rese de fijar los pies de la unidad con tornillos cuando la instale Aseg rese de instalar firmemente la unidad para evitar su desprendimiento en caso de terr...

Page 19: ...s de cobre Siga la normativa eléctrica local ATENCIÓ N Conecte las unidades interior y exterior con el cable de conexi n norma lizado destinado a este fin y sujete bien el cable al panel de terminales de modo que no quede tenso en la zona de conexiones del panel Una conexi n y fijaci n defectuosas podr an provocar un incendio Conecte los cables al n mero correspondiente de terminales Aseg rese de ...

Page 20: ...tapa de la abertura de servicio de la v lvula de retenci n situada en el lado de la tuber a de gas de la unidad exterior Inicialmente las v lvulas de retenci n est n completamente cerradas y cubiertas con sus tapas 2 Conecte la v lvula colectora de man metro y la bomba de vac o al puerto de servicio de la v lvula de retenci n en el lado de la tuber a del gas de la unidad exterior 3 Ponga en funcio...

Page 21: ...a Si no se instala correctamente podr an surgir problemas de funcionamiento 4 3 EXTRACCI N DEL PANEL DE MANTENIMIENTO Panel de mantenimiento 4 4 BLO UEAR EL MODO DE FUNCIONAMIENTO DEL AIRE ACONDICIONADO COOL REFRIGERACI N DR DESHUMIDIFICACI N HEAT CALEFACCI N 4 5 REDUCIR EL RUIDO DE FUNCIONAMIENTO DE LA UNIDAD EXTERIOR Descripci n de la funci n Con esta funci n una vez que el modo de funcionamient...

Page 22: ... utilice el recogedor de refrigerante para recoger todo el refrigerante del sistema y a continuaci n una vez que las unidades interior y exterior se hayan reubicado vuelva a recargar el sistema con la cantidad adecuada de refrigerante 7 Desactive el disyuntor Retire el medidor de presi n y las tuber as de refrigerante Al bombear el refrigerante detenga el compresor antes de desconectar las tuberí ...

Page 23: ...B H79A325H02 HE AD OFFI CE TOKY O B UI LDI NG 2 7 3 MARUNOUCHI CHI Y ODA KU TOKY O 100 8310 JAPAN BH79A325H02_cover4 indd 2 2018 02 09 14 58 05 ...

Reviews: