2

1.   THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR 

SAFETY

   Be sure to read “THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY” before installing 

the air conditioner.

  Be sure to observe the cautions speci

fi

 ed here as they include important items related to safety.

  The indications and meanings are as follows.

 WARNING:  Could lead to death, serious injury, etc.

 CAUTION:   Could lead to serious injury in particular environments when operated incorrectly.

  After reading this manual, be sure to keep it together with the OPERATING INSTRUCTIONS in a 

handy place on the customer’s site.

 WARNING

 

Do not install the unit by yourself (customer).

  Incomplete installation could cause injury due to 

fi

 re, 

electric shock, the unit falling or leakage of water. 
Consult the dealer from whom you purchased the 
unit or special installer.

 

Install the unit securely in a place which can bear 
the weight of the unit.

  When installed in an insuf

fi

 cient strong place, the unit 

could fall causing injury.

 

Use the speci

fi

 ed wires to connect the indoor 

and outdoor units securely and attach the wires 

fi

 rmly to the terminal block connecting sections 

so the stress of the wires is not applied to the 
sections.

 Incomplete 

connecting 

and 

fi

 xing could cause 

fi

 re.

 

Do not use intermediate connection of the power 
cord or the extension cord and do not connect 
many devices to one AC outlet.

  It could cause a 

fi

 re or an electric shock due to de-

fective contact, defective insulation, exceeding the 
permissible current, etc.

 

Check that the refrigerant gas due not leak after 
installation has completed.

  If refrigerant gas leaks indoors, and comes into con-

tact with the 

fi

 re of a fan heater, space heater, stove, 

etc., harmful substances will be generated.

 

Perform the installation securely referring to the 
installation manual.

  Incomplete installation could cause a personal injury 

due to 

fi

 re, electric shock, the unit falling or leakage 

of water.

 

Perform electrical work according to the instal-
lation manual and be sure to use an exclusive 
circuit.

  If the capacity of the power circuit is insuf

fi

 cient  or 

there is insuf

fi

 cient electrical work, it could result in a 

fi

 re or an electric shock.

 

Attach the electrical cover to the indoor unit and 
the service panel to the outdoor unit securely.

  If the electrical cover in the indoor unit and/or the 

service panel in the outdoor unit are not attached se-
curely, it could result in a 

fi

 re or an electric shock due 

to dust water, etc.

 

Be sure to use the part provided or speci

fi

 ed 

parts for the installation work.

  The use of defective parts could cause an injury due 

to a 

fi

 re, an electric shock, the unit falling, leakage of 

water, etc.

 

Be sure to cut off the main power in case of set-
ting up the indoor electronic control P.C. board 
or wiring works.

  It could cause an electric shock.

 

The appliance shall be installed in accordance 
with national wiring regulations.

 

When installing or relocating the unit, make sure 
that no substance other than the speci

fi

 ed refrig-

erant (R410A) enters the refrigerant circuit.

  Any presence of foreign substance such as air can 

cause abnormal pressure rise or an explosion.

 CAUTION

 

Perform earthing.

  Do not connect the earth wire to a gas pipe, water 

pipe, lightning rod or telephone earth wire. Defective 
earthing could cause an electric shock.

 

Do not install the unit in a place where an in

fl

 am-

mable gas leaks.

  If gas leak and accumulate in the area surrounding 

the unit, it could cause an explosion.

 

Fasten a 

fl

 are nut with a torque wrench as speci-

fi

 ed in this manual.

  When fastened too tight, a 

fl

 are nut may broken after 

a long period and cause a leakage of refrigerant.

 

Install an earth leakage breaker depending on the 
installation place (Where it is humid).

  If a earth leakage breaker is not installed, it could 

cause an electric shock.

 

Perform the drainage/piping work securely ac-
cording to the installation manual.

  If there is a defect in the drainage/piping work, water 

could drop from the unit and household goods could 
be wet and damaged.

2. INSTALLATION DIAGRAM & ACCESSORIES

Before installation

This installation manual is only for the outdoor unit installation. In installing the indoor units, refer to the 
installation manual attached to each indoor unit.
Any structural alternations necessary for the installation must comply with the local building code 
requirements.

Open as a rule
More than 500 mm
if the front and both
sides are open

More than 100 mm
More than 200 mm if
there are obstacles to
both sides

More than 100 mm

Open as a rule
More than 500 mm if
the back, both sides
and top are open

More than 350 mm

Note:
The dimensions given along the arrows above are required to guarantee 
the air conditioner’s performance. Install the unit in as wide a place as 
possible for later service or repairs.

K

D

C

I

E

J

F

H

SG79Y644H01.indd   2

SG79Y644H01.indd   2

29.11.2005   17:04:10 Uhr

29.11.2005   17:04:10 Uhr

Summary of Contents for MXZ-2A52VA

Page 1: ...LLATION DIAGRAM ACCESSORIES 2 3 SELECTING THE INSTALLATION LOCATION 3 4 OUTDOOR UNIT INSTALLATION 4 5 INDOOR OUTDOOR UNITS CONNECTION FINISHING AND TEST RUN 5 IMPORTANT NOTES TO COMPLY WITH THE REQUIREMENTS OF AUSTRALIAN STANDARD AS 3000 S A A WIRING RULES THE ELECTRICAL WIRING REQUIRED BETWEEN THE INDOOR AND OUTDOOR UNITS MUST BE INSTALLED BY A LICENCED ELECTRICAL CONTRACTOR SG79Y644H01 indd 1 SG...

Page 2: ...tdoor unit are not attached se curely it could result in a fire or an electric shock due to dust water etc Be sure to use the part provided or specified parts for the installation work The use of defective parts could cause an injury due to a fire an electric shock the unit falling leakage of water etc Be sure to cut off the main power in case of set ting up the indoor electronic control P C board...

Page 3: ...upport is available to prevent the increase of operation sound or vibration Where there is no risk of combustible gas leakage When installing the unit at a high level be sure to fix the unit legs Where it is at least 3 m away from the antenna of TV set or radio Operation of the air conditioner may interfere with radio or TV reception in areas where reception is weak An amplifier may be required fo...

Page 4: ...t Take enough care to connect the indoor outdoor unit connecting wire correctly between the respective indoor units and the outdoor unit Make earth wire a little longer than the others more than 35 mm 35 mm 15 mm POWER SUPPLY LY L N 230 V 50 Hz UNIT UNIT For the power supply cord and the indoor outdoor unit connecting wires be sure to use the ones in compli ance with the standards Be sure to push ...

Page 5: ...A52VA Outdoor unit Indoor unit UNIT Indoor unit UNIT PIPING PREPARATION 1 If you use commercially available copper pipes use the following table for pipe specifications Outside diameter Wall thickness Liquid pipe ø6 35 mm 0 8 mm Gas pipe ø9 52 mm 0 8 mm 2 For insulation material use 8 mm thick heat insulating expended polyethylene with a specific gravity of 0 045 3 Ensure that the 2 refrigerant pi...

Page 6: ...n for prevention of condensation A Die Copper pipe Flare nut Die Copper pipe Smooth all around Even length all around Inside is shining without any scratches Y ork Flaring tool Wing nut type Clutch type 5 4 PURGING PROCEDURES LEAK TEST Perform the manifold valve work securely according to the installation manual of the manifold valve PURGING PROCEDURES Connect the refrigerant pipes both liquid pip...

Page 7: ... can lower the operating noise of the outdoor unit when the operation load is small for example during nighttime in COOL mode However please note that the cooling and heating capacity can also be lowered if this function is acti vated Initial setting is required to activate this function Please explain about this function to your custom ers and ask them whether they want to use it How to lower the...

Page 8: ... cannot detect any erroneous connection if any of the refrigerant pipes and the indoor outdoor unit connecting wires About the restart protective mechanism Once the compressor stops the restart preventive device operates so the compressor will not operate for 3 minutes to protect the air conditioner 5 11 EXPLANATION TO THE CUSTOMER Recommend the customer to read the OPERATING INSTRUCTIONS carefull...

Page 9: ......

Page 10: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN SG79Y644H01 SG79Y644H01 indd 9 SG79Y644H01 indd 9 29 11 2005 17 04 16 Uhr 29 11 2005 17 04 16 Uhr ...

Reviews: