75
4. 09-class unit in single operation (OUTDOOR UNIT : MXZ-3A30NA MXZ-3A30NA -
1
MXZ-4A36NA )
(1) COOL operation
Data is based on the condition of indoor
humidity 50%
Air flow speed : High
Inverter output frequency : 33 Hz
(2) HEAT operation
65 70 75 80 85 90 95 100 105 110 115
110
120
130
140
150
160
Ambient temperature (
˚
F)
(
˚
F)
86
80
75
70
Indoor DB temperature (
˚
F)
65 70 75 80 85 90 95 100 105 110 115
0.0
1.0
2.0
3.0
4.0
5.0
6.0
Ambient temperature (
˚
F)
(
˚
F)
(
˚
F)
15 20 25 30 35 40 45 50 55 60 65 70 75
2.0
3.0
4.0
5.0
6.0
7.0
Ambient temperature (
˚
F)
Outdoor low pressure
Outdoor unit current (A)
Outdoor unit current (A)
45 Hz
(PSIG)
33 Hz
33 Hz
65
75
70
86
80
75
70
Indoor DB temperature (
˚
F)
Indoor DB temperature (
˚
F)
<How to work fixed-frequency operation>
1.Set emergency switch to COOL or HEAT. The switch is
located on indoor unit.
2.Press emergency run ON/OFF button.
3.Compressor starts running at 33 Hz (COOL) or 45 Hz (HEAT).
4.Indoor fan runs at High speed and continues for 30 minutes.
5.To cancel this operation, press emergency run ON/OFF
button or any button on remote controller.
Data is based on the condition of outdoor
humidity 75%.
Set air flow to High speed.
Inverter output frequency is 45 Hz.