14
Indoor intake air Dry-bulb temperature
(°C)
Outdoor intake air Wet-bulb temperature (°C)
Outdoor intake air Wet-bulb temperature (°C)
Indoor intake air Dry-bulb temperature (°C)
Heating capacity
(at Rated frequency)
Total input
(Heating at Rated frequency)
Indoor air W
et-bulb temperature
difference (°C)
MUZ-HJ25V
A
MUZ-HJ35V
A
20.6
19.0
17.4
15.8
14.3
12.7
11.1
9.5
22.9
21.1
19.3
17.6
15.8
14.1
12.3
10.5
MUZ-HJ50V
A
24.7
22.8
20.9
19.0
17.1
15.2
13.3
11.4
NOTE:
The above broken lines are for the heating operation without any frost and
defrost operation.
Indoor air W
et-bulb temperature
difference (°C)
Outdoor intake air Dry-bulb temperature (°C)
MUZ-HJ25V
A
MUZ-HJ35V
A
6.1
5.6
5.1
4.6
4.1
3.6
6.8
6.2
5.6
5.1
4.5
4.0
MUZ-HJ50V
A
9.6
8.7
7.9
7.1
6.3
5.5
18 20
25
30
35
46
45
40
0.8
0.9
1.0
1.1
1.2
1.3
Total input
(Cooling :at Rated frequency)
Input correction factor
22
20
18
Indoor intake air W
et-bulb temperature (°C)
26
24
8-1. CAPACITY AND INPUT CURVES
Indoor air W
et-bulb temperature
difference (°C)
Outdoor intake air Dry-bulb temperature (°C)
MUZ-HJ25V
A
MUZ-HJ50V
A
7.2
6.7
6.1
5.6
5.1
4.6
4.1
11.4
10.5
9.6
8.7
7.9
7.1
6.3
MUZ-HJ35V
A
8.0
7.4
6.8
6.2
5.6
5.1
4.5
18
20
25
30
35
40
46
45
0.9
1.0
1.1
1.2
1.3
1.4
1.5
Indoor intake air W
et-bulb temperature (°C)
Cooling capacity
(at Rated frequency)
Capacity correction factor
22
20
18
26
24
OBH648A