44
PART NAMES AND FUNCTIONS
2
3
SPECIFICATION
Air inlet
Piping
Air outlet
(back and side)
Drain hose
Drain outlet
MUZ-GB50VA
ACCESSORIES
Drain socket
1
Drain cap ø33
2
Outdoor model
MUZ-GB50VA
Function
Cooling
Heating
Power supply
Single phase 230 V, 50 Hz
Capacity Rated frequency (Min.-Max.)
kW
5.0 (0.9-5.8)
5.8 (0.9-7.8)
Electrical
data
Breaker capacity
A
20
Running current 1
A
7.23
7.43
Power input 1
W
1,610
1,660
Power factor 1
%
97
Starting current 1
A
7.46
Coef
fi
cient of performance (C.O.P) 1
3.03
3.41
Compressor
Model
E1
SNB130FLDH or SNB130FLDH1
E2
SNB130FLEH1
E3
SNB130FGBH
Output
E1
,
E2
W
850
E3
900
Compressor motor current 1
A
6.91
7.11
Fan motor
Model
RC0J60-AA
Current 1
A 0.32
Dimensions W × H × D
mm
840 × 850 × 330
Weight
kg
53
Dehumidi
fi
cation
/h
2.2
—
Air
fl
ow 1 (High/Low)
m
3
/h
2,940/1,650
2,940/2,210
Special remarks
Sound level 1 (High/Low)
dB(A)
52/51
55/53
Fan speed (High/Low)
rpm
800/480
800/620
Fan speed regulator
2
Refrigerant
fi
lling capacity (R410A)
kg
1.50
Refrigeration oil (Model)
NEO22
NOTE
: Test conditions are based on ISO 5151.
Cooling : Indoor Dry-bulb temperature 27°C
Wet-bulb temperature 19°C
Outdoor Dry-bulb temperature 35°C
Wet-bulb temperature 24°C
Heating : Indoor Dry-bulb temperature 20°C
Wet-bulb temperature 15°C
Outdoor Dry-bulb temperature 7°C
Wet-bulb temperature 6°C
Refrigerant piping length (one way) : 5 m
1 Measured under rated operating frequency.