26
26
11-4. TROUBLE CRITERION OF MAIN PARTS
MUZ-GB50VA
Part name
Check method and criterion
Figure
Defrost thermistor (RT61)
Ambient temperature
thermistor (RT65)
Outdoor heat exchanger tem-
perature thermistor
(RT68)
Measure the resistance with a tester.
Refer to 11-6. "Test point diagram and voltage", 1. "Outdoor electronic con-
trol P.C. board” or 4. "Inverter P.C. board", for the chart of thermistor.
Discharge temperature
thermistor
(RT62)
Measure the resistance with a tester.
Before measurement, hold the thermistor with your hands to warm it up.
Refer to 11-6. "Test point diagram and voltage", 1. "Outdoor electronic con-
trol P.C. board" or 4. "Inverter P.C. board", for the chart of thermistor.
Fin temperature
thermistor (RT64)
Compressor
Measure the resistance between terminals using a tester.
(Winding temperature : -10 ~ 40°C)
Normal
E1
E2
E3
0.40 ~ 0.49
Ω
0.86 ~ 1.06
Ω
Outdoor fan motor
Measure the resistance between lead wires using a tester.
(Part temperature : -10 ~ 40°C)
Color of lead wire
Normal
RED – BLK
13.4 ~ 16.4
Ω
BLK – WHT
WHT – RED
R. V. coil
Measure the resistance using a tester.
(Part temperature : -10 ~ 40°C)
Normal
E1
E2
E3
2.6 ~ 3.3 k
Ω
0
1.32 ~ 1.62
Ω
Linear expansion valve
Measure the resistance using a tester.
(Part temperature : -10 ~ 40°C)
Color of lead wire
Normal
WHT – RED
37.4 ~ 53.9
Ω
RED – ORN
YLW – BRN
BRN – BLU
W
U
V
WHT
RED
BLK
LEV
WHT
RED
YLW BRN
ORN
BLU
U
RED
WHT
BLK
V
W
(W)
(V)
(U)
Summary of Contents for MUZ-GB50VA