REFRIGERANT SYSTEM DIAGRAM
Unit: inch
Outdoor
heat
exchanger
Flared connection
Defrost
thermistor
RT61
Discharge
temperature
thermistor
RT62
Flared connection
Stop valve
(with strainer)
Stop valve
Refrigerant flow in cooling
Compressor
4-way valve
Refrigerant flow in heating
Refrigerant pipe ø3/8
(with heat insulator)
Refrigerant pipe ø1/4
(with heat insulator)
R.V. coil
heating ON
cooling OFF
Strainer
#100
LEV
Ambient
temperature
thermistor
RT65
Muffler
Capillary tube
O.D. 0.157 ×
I.D. 0.094 × 9-7/16
(ø4.0 × ø2.4 × 240)
Outdoor heat
exchanger
temperature
thermistor
RT68
Capillary tube
O.D. 0.118 ×
I.D. 0.079 × 8-9/32
(ø3.0 × ø2.0 × 210)
Service port
(high pressure)
Service port
(low pressure)
Muffler
MUZ-FS06NA MUZ-FS06NAH MUZ-FS09NA MUZ-FS09NAH MUZ-FS12NA MUZ-FS12NAH
MUZ-FS15NA MUZ-FS15NAH MUZ-FS18NA MUZ-FS18NAH
Outdoor
heat
exchanger
Flared connection
Defrost
thermistor
RT61
Discharge
temperature
thermistor
RT62
Flared connection
Stop valve
Stop valve
Capillary tube
O.D. 0.157 ×
I.D. 0.094× 3-15/16
(ø4.0×ø2.4×100)
Refrigerant flow in cooling
Compressor
4-way valve
Refrigerant flow in heating
Refrigerant pipe ø1/2
(with heat insulator)
Refrigerant pipe
ø1/4
(with heat insulator)
LEV
Muffler
R.V. coil
heating ON
cooling OFF
Muffler,
#100 strainer
Strainer
#100
Outdoor heat
exchanger
temperature
thermistor
RT68
Ambient
temperature
thermistor
RT65
Strainer
#100
Service port
(low pressure)
Muffler
ACC
Service port
(high pressure)
Capillary tube
O.D. 0.118 ×
I.D. 0.079 × 9-7/16
(ø3.0 × ø2.0 × 240)
OBH873