10-1. MU-GF20VA MU-GF25VA MU-GF35VA
NOTE
: Turn OFF power supply before disassembly.
OPERATING PROCEDURE
PHOTOS
1. Removing the cabinet
(1) Remove the screw fixing the service panel and service
panel.
(2) Disconnect the indoor/outdoor connecting wire.
(3) Remove the screw of the valve cover and the valve
cover.
(4) Remove the screws fixing the top panel.
(5) Remove the top panel.
(6) Remove the screws fixing the cabinet.
(7) Remove the cabinet.
(8) Remove the screws fixing the back panel.
(9) Remove the back panel.
Photo 1
Photo 2
31
(1) Slide the sleeve and check if there is a locking lever or not.
(2) The terminal with this connector has the
locking mechanism.
Slide the sleeve.
Pull the terminal while
pushing the locking
lever.
Hold the sleeve, and
pull out the terminal
slowly.
Connector
Sleeve
Locking lever
<"Terminal with locking mechanism" Detaching points>
The terminal which has the locking mechanism can be detached as shown below.
There are two types (refer to (1) and (2)) of the terminal with locking mechanism.
The terminal without locking mechanism can be detached by pulling it out.
Check the shape of the terminal before detaching.
DISASSEMBLY INSTRUCTIONS
10
Screws of the cabinet
Photo 3
Screws of
the top panel
Screws of
the cabinet
Screws of the
top panel
Screw of the
cabinet
Screws of the
service panel
Screw of the
valve cover
Screws of
the back
panel
Screws of the
back panel
Screw of
the top panel
Screws fixing the
motor support
and the fan motor
OBH622A