4. Removing the compressor
(1) Remove the cabinet. (Refer to 1.)
(2) Remove the relay panel.
(3) Remove the soundproof felt.
(4) Remove the terminal cover on compressor.
(5) Disconnect lead wires from the glass terminal of the com-
pressor.
(6) Recover gas from the refrigerant circuit.
NOTE
●
Recover gas from the pipes until the pressure gauge shows
0 PSIG.
(7) Disconnect the welded part of the suction pipe and dis-
charge pipe.
(8) Remove the nuts fixing the compressor.
(9) Remove the compressor.
Photo 5
Compressor
Compressor nuts
Suction pipe
Discharge pipe