4
R410A tools
Can R22 tools be used?
Gas leak detector
R410A has high pressures beyond the measurement range of existing
gauges.
Hose material have been changed to improve the pressure resistance.
Dedicated for HFC refrigerant.
1/4in. and 3/8in.
Description
Clamp bar hole has been enlarged to reinforce the spring strength in the tool.
Provided for flaring work (to be used with R22 flare tool).
Provided to prevent the back flow of oil. This adapter enables you to use
vacuum pumps.
It is difficult to measure R410A with a charging cylinder because the
refrigerant bubbles due to high pressure and high-speed vaporization
No
No
No
Yes
Yes
New
New
New
Gauge manifold
Charge hose
Torque wrench
Flare tool
Flare gauge
Vacuum pump
adapter
Electronic scale for
refrigerant charging
No : Not Substitutable for R410A Yes : Substitutable for R410A
No
1/2in. and 5/8in.
1.Tools dedicated for the air conditioner with R410A refrigerant
The following tools are required for R410A refrigerant. Some R22 tools can be substituted for R410A tools.
R410A
Pipe diameter
inch
1/4
3/8
1/2
5/8
17 (11/16)
22 (7/8)
26 (1-1/32)
29 (1-5/32)
Dimension of flare nut
R22
mm(in.)
17 (11/16)
22 (7/8)
24 (15/16)
27 (1-1/16)
2
Flaring work and flare nut
Flaring work for R410A pipe differs from that for R22 pipe.
For details of flaring work, refer to Installation manual “FLARING WORK”.
2.Refrigerant piping
1
Specifications
Use the copper or copper-alloy seamless pipes for refrigerant that meet the following specifications.
Wall thickness (in)
Outside diameter(in)
1/4
3/8
1/2
5/8
0.0315
0.0315
0.0315
0.0394
Heat resisting foam plastic
Specific gravity 0.045 Thickness 0.315 in
Insulation material
OB449A.qxp 06.5.9 11:13 AM Page 4