This product is designed and intended for use in the residential, commercial 

and light-industrial environment.

HEAD OFFICE: TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, 
TOKYO 100-8310, JAPAN

6-1. REMOVING AND INSTALLING THE PANEL ASSEMBLY

6-3. PUMPING DOWN

When relocating or disposing of the air conditioner, pump down the system following 
the procedure below so that no refrigerant is released into the atmosphere.
1) Connect the gauge manifold valve to the service port of the stop valve on the gas 

pipe side of the outdoor unit.

2) Fully close the stop valve on the liquid pipe side of the outdoor unit.
3) Close the stop valve on the gas pipe side of the outdoor unit almost completely so 

WKDWLWFDQEHHDVLO\FORVHGIXOO\ZKHQWKHSUHVVXUHJDXJHVKRZV03D>*DXJH@

kgf/cm²).

4) Start the emergency COOL operation.
 

To start the emergency operation in COOL mode, disconnect the power supply plug 
and/or turn off the breaker. After 15 seconds, connect the power supply plug and/
or turn on the breaker, and then press the E.O. SW once. (The emergency COOL 
operation can be performed continuously for up to 30 minutes.)

5) Fully close the stop valve on the gas pipe side of the outdoor unit when the pressure 

JDXJHVKRZVWR03D>*DXJH@DSSUR[WRNJIFPð

6) Stop the emergency COOL operation.

  Press  the  E.O.  SW  several  times  until  all  LED  lamps  turn  off.  Refer  to  operating 

instructions for details.

6.  RELOCATION AND MAINTENANCE

When pumping down the refrigerant, stop the compressor before disconnecting 
the refrigerant pipes. The compressor may burst if air etc. get into it.

 WARNING

6-2. REMOVING THE INDOOR UNIT

Remove the bottom of the indoor unit from the installation 
plate.
When releasing the corner boxes, release both left and 

right bottom corner part of indoor unit and pull it down-

ZDUGDQGIRUZDUGDVVKRZQLQWKH¿JXUHRQWKHULJKW

Removal procedure

1) Insert a screwdriver deeply into the holes.
2)  Pry off the right and left arm holders by moving the screwdriver down and towards 

the back wall.

3) Remove the safety string from the upper center of the panel assembly.

Installation procedure

1) Install the panel assembly following the removal 

procedure in reverse. 

2) Be  sure  to  press  the  positions  as  indicated  by  the 

arrows in order to attach the assembly completely to 
the unit.

2

3

1

Hold the panel with your hand while 
detaching it to avoid injury. 

 CAUTION

7.  CONNECTING THE INTERFACE/CONNECTOR CABLE TO THE AIR CONDITIONER

Fix the connecting cable at the prescribed position securely. Incorrect installation 

PD\FDXVHHOHFWULFVKRFN¿UHDQGRUPDOIXQFWLRQ

 WARNING

•  Connect the INTERFACE/CONNECTOR CABLE to the indoor control P.C. board of the air conditioner with a connecting cable.
•  Cutting or extending the connecting cable of the INTERFACE/CONNECTOR CABLE results in defects in connecting. 
  Do not bundle the connecting cable together with power supply cord, indoor/outdoor connecting wire, and/or earth wire. Keep as much distance as possible between the con-

necting cable and those wires. 

•  The thin part of the connecting cable should be stored and placed where customers cannot touch it.

1

  Remove the panel and the lower right corner box.

2

  Open the covers of the indoor control P.C. board.

3

  Join the connecting cable to CN105 and/or CN104 on the indoor control P.C. board. 

 3DVVWKHWKLQSDUWRIWKHFRQQHFWLQJFDEOHWKURXJKWKHULEDVVKRZQLQWKH¿JXUH

4

  Attach the cable clamp provided with Interface to the thick part of the connecting cable with a screw 4×16 as shown in the 

¿JXUH

 3DVVWKHFRQQHFWLQJFDEOHWKURXJKWKHULEDVVKRZQLQWKH¿JXUH

5

  Close the covers of the indoor control P.C. board. Be careful not to catch the thin part of the connecting cable in the cover.

 

Reinstall the panel and the lower right corner box.

Connecting

Thick part of the connecting cable

Air conditioner

Thin part of the connecting cable. 
Place this part where customers cannot touch it.

Indoor control 
P.C. board

CN105 for INTERFACE

CN104 for CONNECTOR CABLE

Summary of Contents for MSZ-LN18VG2

Page 1: ...F VKRFN WKH unit falling etc When plugging the power supply plug into the outlet make sure that there is no dust clogging or loose parts in both the outlet and the plug Make sure that the power supply plug is pushed com pletely into the outlet If there is dust clogging or loose parts on the power supply plug or the outlet it could cause electric shock or UH I ORRVH SDUWV DUH IRXQG RQ WKH SRZHU VXS...

Page 2: ... QVWDOO WKH XQLW KRUL RQWDOO Please install it in an area not affected by snowfall or blowing snow In areas with KHDY VQRZ SOHDVH LQVWDOO D FDQRS D SHGHVWDO DQG RU VRPH EDIÀH ERDUGV Note It is advisable to make a piping loop near outdoor unit so as to reduce vibration transmitted from there WARNING 7KH XQLW VKRXOG EH LQVWDOOHG LQ URRPV ZKLFK KDYH WKH ÀRRU VSDFH VSHFL HG below LN50VG2 2 5 m LN50VGH...

Page 3: ...QVWDOODWLRQ SODWH LQJ VFUHZ 4 25 mm 5 3 Wireless remote controller 1 4 Felt tape For left or left rear piping 1 5 Corner box R 4 6 Corner box L 4 7 Battery AAA for 3 2 8 LU FOHDQLQJ OWHU 1 9 Air purifying device 1 Outdoor unit 10 Drain socket VG type only 1 Air inlet LN25 35 50 50HZ 60 LN25 35 50 50HZ 60 3 When any 2 sides of left right and rear of unit are clear 4 The manufacturing year and month...

Page 4: ...drain piping as shown below Do not raise Accumulated drain water Air Waving Water leakage Water leakage Water leakage Tip of drain hose dipped in water Ditch At least 50 mm gap Downward slope Drain hose Soft hose I D 15 mm Drain hose Hard vinyl chloride pipe I D 30 mm Insert securely Different diameter joint 70 cm or more Fig 1 Fig 2 Fig 3 For future servicing give extra length to the connecting w...

Page 5: ...1 part about 90 degrees around the hinge point you have just created to put the parts together 3 Press the base of portion with the mark to snap into place When changing the part disassemble by moving the part in a reverse direction The parts that were not used may be necessary in the future if the air conditioner is relocated so ask customers to keep those parts 4 Attach the assembled corner box ...

Page 6: ...t any scratches Flare nut Die Fig 5 Fig 6 3 OUTDOOR UNIT INSTALLATION Copper pipe Wing nut type WARNING When installing the unit securely connect the refrigerant pipes before starting the compressor 3 1 CONNECTING WIRES FOR OUTDOOR UNIT 1 Open the service panel 2 Loosen terminal screw and connect indoor outdoor unit connecting wire A from the indoor unit correctly on the terminal block Be careful ...

Page 7: ...art operation automatically when power supply is resumed To the user After installing the unit make sure to explain the user about auto restart function If auto restart function is unnecessary it can be deactivated Consult the service representative to deactivate the function Refer to the service manual for details 4 PURGING PROCEDURES LEAK TEST AND TEST RUN Pressure gauge for R32 R410A Emergency ...

Page 8: ...river deeply into the holes 2 Pry off the right and left arm holders by moving the screwdriver down and towards the back wall 3 Remove the safety string from the upper center of the panel assembly Installation procedure 1 Install the panel assembly following the removal procedure in reverse 2 Be sure to press the positions as indicated by the arrows in order to attach the assembly completely to th...