1-4. INSTALLATION DIAGRAM

When the piping is to be attached to a wall containing metals (tin plated) or metal 
netting, use a chemically treated wooden piece 20 mm or thicker between the 
wall and the piping or wrap 7 to 8 turns of insulation vinyl tape around the piping.
To use existing piping, perform COOL operation for 30 minutes and pump 

GRZQEHIRUHUHPRYLQJWKHROGDLUFRQGLWLRQHU5HPDNHÀDUHDFFRUGLQJWRWKH

dimension for new refrigerant.

Appearance of the outdoor unit may differ from some models.

102 mm 

or more

1.8 m to 2.3 m from the 

ÀRRULVUHFRPPHQGHG

clear *2

100 mm 

or more

100 mm 

or more

200/500 mm *3 

or more

Air inlet

Air outlet

Outdoor unit installation

(LN25, 35, 50/50HZ, 60)

40 mm

2-10 mm × 21 mm slot

800/840 mm

150/175 

mm

500 mm

344.5/390 mm

285/330 mm

304-325/

349-371 mm

*2 100/500 mm or more when front and 

sides of unit are clear

Note:

*1 Place indoor/outdoor unit connecting wire (A) and 

power supply cord (K) at least 1 m away from the TV 
antenna wire.

After the leak test, apply insulating material tightly 
so that there is no gap.

 WARNING

7RDYRLGULVNRI¿UHHPEHGRUSURWHFWWKHUHIULJHUDQWSLSLQJ
([WHUQDOGDPDJHRQWKHUHIULJHUDQWSLSLQJFDQEHFDXVHRI¿UH

PARTS TO BE PROVIDED AT YOUR SITE

(A) Indoor/outdoor unit connecting wire*1

1

(B) Extension pipe

1

(C) Wall hole sleeve

1

(D) Wall hole cover

1

(E)

3LSH¿[LQJEDQG

2 to 5

(F) Fixing screw for (E) 4 × 20 mm

2 to 5

(G) Piping tape

1

(H) Putty

1

(I)

Drain hose 

(or soft PVC hose, 15 mm inner 
diameter or hard PVC pipe VP16)

1 or 2

(J) Refrigeration oil

1

(K) Power supply cord*1

1

ACCESSORIES

Check the following parts before installation.
<Indoor unit>

(1) Installation plate

1

(2)

,QVWDOODWLRQSODWH¿[LQJVFUHZ

4 × 25 mm

5

(3) Wireless remote controller

1

(4)

Felt tape 

(For left or left-rear piping)

1

(5) Corner box R 

4

(6) Corner box L 

4

(7) Battery (AAA) for (3)

2

(8)

$LUFOHDQLQJ¿OWHU

1

(9) Air purifying device

1

<Outdoor unit>

(10) Drain socket (VG type only)

1

Air inlet

(LN25, 35, 50/50HZ, 60)

(LN25, 35, 50/50HZ, 60)

*3 When any 2 sides of left, right and rear of unit are clear
*4 The manufacturing year and month is indicated on the 

spec name plate.

IMPORTANT NOTES 

Check that cabling will not be subject to wear, corrosion, excessive pressure, 
vibration, sharp edges or any other adverse environmental effects. The check 
shall also take into account the effects of aging or continual vibration from 
sources such as compressors or fans.

60 mm or more/ 

150 mm or more 

for left/left rear piping 

(using spacer)

101 mm 

or more

111 mm 

or more

350 mm 

or more

Be sure to use wall hole sleeve (C) 
to prevent indoor/outdoor connect-

ing wire (A) from contacting metal 
parts in the wall and to prevent 
damage by rodents in case the 
wall is hollow.

Indoor unit

Wall hole 
sleeve (C)

Cut off the 
extra length.

3LSH¿[LQJEDQG(

Wall hole cover (D)

Fixing screw (F)

Seal the wall hole 
gap with putty (H).

Fix the pipe to wall 

ZLWKSLSH¿[LQJEDQG

(E).

This indoor unit is equipped with the built-in Wi-Fi interface.

(10)

(I)

Note:

,QVWDOOWKHXQLWKRUL]RQWDOO\
'RQRWXVHGUDLQVRFNHWLQFROGUHJLRQV'UDLQPD\IUHH]HDQGPDNHWKH

fan stop.
The outdoor unit produces condensate during the heating operation. Select 
the installation place to ensure to prevent the outdoor unit and/or the grounds 

IURPEHLQJZHWE\GUDLQZDWHURUGDPDJHGE\IUR]HQGUDLQZDWHU

Drain piping for outdoor unit 
<VG type only>

• Provide drain piping before indoor and outdoor pip-

ing connection. 

• Connect drain hose (I) I.D.15 mm as shown in the 

illustration.

•  Make  sure  to  provide  drain  piping  with  a  downhill 

JUDGHIRUHDV\GUDLQÀRZ

Summary of Contents for MSZ-LN18VG2

Page 1: ...F VKRFN WKH unit falling etc When plugging the power supply plug into the outlet make sure that there is no dust clogging or loose parts in both the outlet and the plug Make sure that the power supply plug is pushed com pletely into the outlet If there is dust clogging or loose parts on the power supply plug or the outlet it could cause electric shock or UH I ORRVH SDUWV DUH IRXQG RQ WKH SRZHU VXS...

Page 2: ... QVWDOO WKH XQLW KRUL RQWDOO Please install it in an area not affected by snowfall or blowing snow In areas with KHDY VQRZ SOHDVH LQVWDOO D FDQRS D SHGHVWDO DQG RU VRPH EDIÀH ERDUGV Note It is advisable to make a piping loop near outdoor unit so as to reduce vibration transmitted from there WARNING 7KH XQLW VKRXOG EH LQVWDOOHG LQ URRPV ZKLFK KDYH WKH ÀRRU VSDFH VSHFL HG below LN50VG2 2 5 m LN50VGH...

Page 3: ...QVWDOODWLRQ SODWH LQJ VFUHZ 4 25 mm 5 3 Wireless remote controller 1 4 Felt tape For left or left rear piping 1 5 Corner box R 4 6 Corner box L 4 7 Battery AAA for 3 2 8 LU FOHDQLQJ OWHU 1 9 Air purifying device 1 Outdoor unit 10 Drain socket VG type only 1 Air inlet LN25 35 50 50HZ 60 LN25 35 50 50HZ 60 3 When any 2 sides of left right and rear of unit are clear 4 The manufacturing year and month...

Page 4: ...drain piping as shown below Do not raise Accumulated drain water Air Waving Water leakage Water leakage Water leakage Tip of drain hose dipped in water Ditch At least 50 mm gap Downward slope Drain hose Soft hose I D 15 mm Drain hose Hard vinyl chloride pipe I D 30 mm Insert securely Different diameter joint 70 cm or more Fig 1 Fig 2 Fig 3 For future servicing give extra length to the connecting w...

Page 5: ...1 part about 90 degrees around the hinge point you have just created to put the parts together 3 Press the base of portion with the mark to snap into place When changing the part disassemble by moving the part in a reverse direction The parts that were not used may be necessary in the future if the air conditioner is relocated so ask customers to keep those parts 4 Attach the assembled corner box ...

Page 6: ...t any scratches Flare nut Die Fig 5 Fig 6 3 OUTDOOR UNIT INSTALLATION Copper pipe Wing nut type WARNING When installing the unit securely connect the refrigerant pipes before starting the compressor 3 1 CONNECTING WIRES FOR OUTDOOR UNIT 1 Open the service panel 2 Loosen terminal screw and connect indoor outdoor unit connecting wire A from the indoor unit correctly on the terminal block Be careful ...

Page 7: ...art operation automatically when power supply is resumed To the user After installing the unit make sure to explain the user about auto restart function If auto restart function is unnecessary it can be deactivated Consult the service representative to deactivate the function Refer to the service manual for details 4 PURGING PROCEDURES LEAK TEST AND TEST RUN Pressure gauge for R32 R410A Emergency ...

Page 8: ...river deeply into the holes 2 Pry off the right and left arm holders by moving the screwdriver down and towards the back wall 3 Remove the safety string from the upper center of the panel assembly Installation procedure 1 Install the panel assembly following the removal procedure in reverse 2 Be sure to press the positions as indicated by the arrows in order to attach the assembly completely to th...

Reviews: