8
MSZ-HJ60VA
MSZ-HJ71VA
90
80
70
60
50
40
30
20
10
63
125
250
500
1000
2000
4000
8000
NC-60
NC-50
NC-40
NC-30
NC-20
NC-70
OCT
A
VE BAND SOUND PRESSURE LEVEL, dB re 0.0002 MICRO BAR
BAND CENTER FREQUENCIES, Hz
COOLING
FUNCTION
SPL(dB(A))
LINE
Super High
FAN SPEED
HEATING
50
49
NC-10
90
80
70
60
50
40
30
20
10
63
125
250
500
1000
2000
4000
8000
NC-60
NC-50
NC-40
NC-30
NC-20
NC-70
OCT
A
VE BAND SOUND PRESSURE LEVEL, dB re 0.0002 MICRO BAR
BAND CENTER FREQUENCIES, Hz
COOLING
FUNCTION
SPL(dB(A))
LINE
Super High
FAN SPEED
HEATING
50
49
NC-10
INDOOR UNIT
WALL
MICROPHONE
0.8m
1m
Test conditions
Cooling : Dry-bulb temperature 27°C Wet-bulb temperature 19°C
Heating : Dry-bulb temperature 20°C
OBH647D