19
(8) Cold air prevention in HEAT operation.
The horizontal vane position is set to Upward.
NOTE:
When 2 or more indoor units are operated with multi outdoor unit, even if any indoor unit turns thermostat off,
this control does not work in the indoor unit.
(9) ECONO COOL ( ) operation (ECONOmical operation)
When ECONO COOL button is pressed in COOL mode, set temperature is automatically set 2°C higher.
Also the horizontal vane swings in various cycle.
SWING operation makes you feel cooler than set temperature. So, even though the set temperature is higher, the air
conditioner can keep comfort. As a result, energy can be saved.
ECONO COOL operation is cancelled when ECONO COOL button is pressed once again or VANE CONTROL button is
pressed or change to other operation mode.
9-5. TIMER OPERATION (ON/OFF TIMER)
1. How to set the timer
(1) Press OPERATE/STOP (ON/OFF) (
HJ·VA-
E1
,
ER1
) / STOP/OPERATE (OFF/ON) (
HJ·VA-
E2
,
ER2
) button to start
the air conditioner.
(2) Select the timer mode by pressing the
button during operation.
Each time this button is pressed, the timer mode is changed in sequence:
(OFF TIMER)
→
(ON TIMER)
→
TIMER RELEASE
(3) Set the time of the timer using the
button.
Each time this button is pressed, the set time increase or decrease by 1 hour to 12 hours.
2. To release the timer
Press
the
button until
(OFF TIMER) and
(ON TIMER) are not displayed.
NOTE :
• The OFF TIMER and the ON TIMER cannot be set at the same time.
• The displayed time is the time remaining and will decrease in 1-hour increments as time passes.
EMERGENCY OPERATION switch
9-6. EMERGENCY/TEST OPERATION
In the case of test run operation or emergency operation, use EMERGENCY OPERATION switch on the right side of the
indoor unit. Emergency operation is available when the remote controller is missing or has failed, or when the batteries in
the remote controller are running down. The unit will start and OPERATION INDICATOR lamp will light up.
The first 30 minutes of operation is the test run operation. This operation is for servicing. The indoor fan runs at High
speed and the temperature control does not work.
After 30 minutes of test run operation, the system shifts to EMERGENCY COOL/HEAT MODE with a set temperature of
24°C. The fan speed shifts to Med.
The coil frost prevention works even in the test run or the emergency operation.
In the test run or emergency operation, the horizontal vane operates in VANE AUTO ( ) mode.
Emergency operation continues until EMERGENCY OPERATION switch is pressed once or twice or the unit receives any
signal from the remote controller. In the latter case, normal operation will start.
NOTE:
Do not press EMERGENCY OPERATION switch during normal operation.
Operation mode
COOL
HEAT
Set temperature
24°C
24°C
Fan speed
Med.
Med.
Horizontal vane
Auto
Auto
The operation mode is indicated by the
Operation Indicator lamp as follows:
Operation Indicator lamp
EMERGENCY COOL
↓
EMERGENCY HEAT
↓
STOP
Lighted
Not
lighted
9-7. 3-MINUTE TIME DELAY OPERATION
When the system turns OFF, compressor will not restart for 3 minutes as 3-minute time delay function operates to protect
compressor from overload.
OBH647D