1-4. INSTALLATION DIAGRAM

When the piping is to be attached to a wall containing metals (tin plated) 
or metal netting, use a chemically treated wooden piece 20 mm or thicker 
between the wall and the piping or wrap 7 to 8 turns of insulation vinyl tape 
around the piping.
To use existing piping, perform COOL operation for 30 minutes and pump 

GRZQEHIRUHUHPRYLQJWKHROGDLUFRQGLWLRQHU5HPDNHÀDUHDFFRUGLQJWR

the dimension for new refrigerant.

Appearance of the outdoor unit may differ from some models.

140 

mm 

or more

12 

mm 

or more

1.8 m to 2.3 m from the 

ÀRRULVUHFRPPHQGHG

clear *2

100 mm 

or more

100 mm 

or more

350 mm 

or more

500 mm *3 

or more

Air inlet

Air outlet

Outdoor unit installation 

40 mm

2-10 mm × 21 mm slot

840 mm

175 mm

500 mm

390 mm

330 mm

349-371 mm

*2  500 mm or more when front and 

sides of unit are clear

Note:

*1 Place indoor/outdoor unit connecting wire (A)   

and power supply cord (K)  at least 1 m away 
from the TV antenna wire.

*3  When any 2 sides of left, right and rear of 

unit are clear

Drain piping for outdoor unit 

‡ 3URYLGH GUDLQ SLSLQJ EHIRUH LQGRRU DQG

outdoor piping connection. 

‡&RQQHFWGUDLQKRVH,,'PPDVVKRZQ

in the illustration.

‡0DNHVXUHWRSURYLGHGUDLQSLSLQJZLWKD

GRZQKLOOJUDGHIRUHDV\GUDLQÀRZ

Note:

Install the unit horizontally.
Do not use drain socket (9) in cold regions. Drain may freeze and 
make the fan stop.
The outdoor unit produces condensate during the heating operation. 
Select the installation place to ensure to prevent the outdoor unit and/
or the grounds from being wet by drain water or damaged by frozen 
drain water.

IMPORTANT NOTES  

 

         

‡

Units should be installed by licensed contractor according to local code 
requirements.

‡

To comply with the requirements of Australian standard AS/NZS 3000 
electrical installations (wiring rules), the electrical wiring required between 
the indoor and outdoor units must be installed by a licenced electrical 
contractor

‡

Check that cabling will not be subject to wear, corrosion, excessive pres-
sure, vibration, sharp edges or any other adverse environmental effects. 
The check shall also take into account the effects of aging or continual 
vibration from sources such as compressors or fans.

 

 

         

After the leak test, apply insulating material tightly so 

that there is no gap.

 

WARNING

7RDYRLGULVNRI¿UHÀDUHFRQQHFWLRQVKRXOGEHLQVWDOOHGRXWGRRUV
5HXVDEOHPHFKDQLFDOFRQQHFWRUVDQGÀDUHGMRLQWVDUHQRWDOORZHG

indoors.

 

WARNING

7RDYRLGULVNRI¿UHHPEHGRUSURWHFWWKHUHIULJHUDQWSLSLQJ
([WHUQDOGDPDJHRQWKHUHIULJHUDQWSLSLQJFDQEHFDXVHRI¿UH

Be sure to use wall hole 
sleeve (C) to prevent in-
door/outdoor connecting 
wire (A) from contacting 
metal parts in the wall 
and to prevent damage by 
rodents in case the wall 
is hollow.

Indoor unit

Wall hole 
sleeve (C)

Cut off the 
extra length.

3LSH¿[LQJEDQG(

Wall hole cover (D)

Seal the wall hole gap 

with putty (H).

Fix the pipe to wall 

ZLWKSLSH¿[LQJEDQG

(E).

Fixing screw (F)

(9)

(I)

PARTS TO BE PROVIDED AT YOUR SITE

(A) Indoor/outdoor unit connecting wire*1

1

(B) Extension pipe

1

(C) Wall hole sleeve

1

(D) Wall hole cover

1

(E)

3LSH¿[LQJEDQG

2 to 5

(F) Fixing screw for (E) 4 × 20 mm

2 to 5

(G) Piping tape

1

(H) Putty

1

(I)

Drain hose 
(or soft PVC hose, 15 mm inner 
diameter or hard PVC pipe VP16)

1 or 2

(J) Refrigeration oil

1

(K) Power supply cord*1

1

ACCESSORIES

Check the following parts before installation.
<Indoor unit>

(1) Installation plate

1

(2)

,QVWDOODWLRQSODWH¿[LQJVFUHZ

4 × 25 mm

7

(3) Wireless remote controller

1

(4)

Felt tape 
(For left or left-rear piping)

1

(5) Remote controller holder

1

(6)

Fixing screw for (5) 3.5 × 16 mm 
(Black)

2

(7) Battery (AAA) for (3)

2

(8)

$LUFOHDQLQJ¿OWHU

2

<Outdoor unit>

(9) Drain socket

1

Air inlet

Summary of Contents for MSZ-GL71VGD

Page 1: ...that there is no dust clogging or loose parts in both the outlet and the plug Make sure that the power supply plug is pushed completely into the outlet If there is dust clogging or loose parts on the power supply plug or the outlet it could cause electric shock or UH I ORRVH SDUWV DUH IRXQG RQ WKH SRZHU VXSSO SOXJ replace it Attach the electrical cover to the indoor unit and the service panel to t...

Page 2: ...maldehyde etc which may cause chemical cracking 7KH DSSOLDQFH VKDOO EH VWRUHG VR DV WR SUHYHQW PHFKDQLFDO GDPDJH IURP RFFXUULQJ Pipe length and height difference Max pipe length 30 m Max height difference 15 m Max number of bends 6 7 10 Refrigerant adjustment A 8 20 g m Insulation thickness 9 10 8 mm INDOOR UNIT WARNING Install the indoor unit in rooms which exceed 3 1 m2 KHUH DLUÀRZ LV QRW EORFNH...

Page 3: ...to local code requirements To comply with the requirements of Australian standard AS NZS 3000 electrical installations wiring rules the electrical wiring required between the indoor and outdoor units must be installed by a licenced electrical contractor Check that cabling will not be subject to wear corrosion excessive pres sure vibration sharp edges or any other adverse environmental effects The ...

Page 4: ...the front panel 1 Open the front panel 2 Remove VA clamp 3 Pass indoor outdoor unit connecting wire A from the back of the indoor unit and process the end of the wire RRVHQ WHUPLQDO VFUHZ DQG FRQQHFW UVW WKH HDUWK ZLUH WKHQ LQGRRU RXWGRRU XQLW FRQ necting wire A to the terminal block Be careful not to make mis wiring Fix the wire to the terminal block securely so that no part of its core is appear...

Page 5: ...and no external force is conveyed to the connecting section of the terminal block 3 Firmly tighten the terminal screws to prevent them from loosening After tightening SXOO WKH ZLUHV OLJKWO WR FRQ UP WKDW WKH GR QRW PRYH 4 Connect power supply cord K 5 Fix indoor outdoor unit connecting wire A and power supply cord K with the cord clamp 6 Close the service panel securely 0DNH HDUWK ZLUH D OLWWOH OR...

Page 6: ...ompound pressure gauge for R32 R410A 0 101 MPa 760 mmHg Handle Low Handle High Adapter for preventing the EDFN ÀRZ Charge hose for R32 R410A Close Open Hexagonal wrench Precautions when using the control valve When attaching the control valve to the service port valve core may deform or loosen if excess pressure is applied This may cause gas leak Service port Body Close R32 Open Control valve A Wh...

Page 7: ...MPa Gauge approx 0 5 to 0 kgf cm2 6 Stop the emergency COOL operation Press the E O SW several times until all LED lamps turn off Refer to operating instruc tions for details 5 RELOCATION AND MAINTENANCE When pumping down the refrigerant stop the compressor before disconnecting the refrigerant pipes The compressor may burst if air etc get into it WARNING 5 2 REMOVING THE INDOOR UNIT Remove the bot...

Page 8: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN ...

Reviews: