1-4. INSTALLATION DIAGRAM
When the piping is to be attached to a wall containing metals (tin plated)
or metal netting, use a chemically treated wooden piece 20 mm or thicker
between the wall and the piping or wrap 7 to 8 turns of insulation vinyl tape
around the piping.
To use existing piping, perform COOL operation for 30 minutes and pump
GRZQEHIRUHUHPRYLQJWKHROGDLUFRQGLWLRQHU5HPDNHÀDUHDFFRUGLQJWR
the dimension for new refrigerant.
Appearance of the outdoor unit may differ from some models.
140
mm
or more
12
mm
or more
1.8 m to 2.3 m from the
ÀRRULVUHFRPPHQGHG
clear *2
100 mm
or more
100 mm
or more
350 mm
or more
500 mm *3
or more
Air inlet
Air outlet
Outdoor unit installation
40 mm
2-10 mm × 21 mm slot
840 mm
175 mm
500 mm
390 mm
330 mm
349-371 mm
*2 500 mm or more when front and
sides of unit are clear
Note:
*1 Place indoor/outdoor unit connecting wire (A)
and power supply cord (K) at least 1 m away
from the TV antenna wire.
*3 When any 2 sides of left, right and rear of
unit are clear
Drain piping for outdoor unit
3URYLGH GUDLQ SLSLQJ EHIRUH LQGRRU DQG
outdoor piping connection.
&RQQHFWGUDLQKRVH,,'PPDVVKRZQ
in the illustration.
0DNHVXUHWRSURYLGHGUDLQSLSLQJZLWKD
GRZQKLOOJUDGHIRUHDV\GUDLQÀRZ
Note:
Install the unit horizontally.
Do not use drain socket (9) in cold regions. Drain may freeze and
make the fan stop.
The outdoor unit produces condensate during the heating operation.
Select the installation place to ensure to prevent the outdoor unit and/
or the grounds from being wet by drain water or damaged by frozen
drain water.
IMPORTANT NOTES
Units should be installed by licensed contractor according to local code
requirements.
To comply with the requirements of Australian standard AS/NZS 3000
electrical installations (wiring rules), the electrical wiring required between
the indoor and outdoor units must be installed by a licenced electrical
contractor
.
Check that cabling will not be subject to wear, corrosion, excessive pres-
sure, vibration, sharp edges or any other adverse environmental effects.
The check shall also take into account the effects of aging or continual
vibration from sources such as compressors or fans.
After the leak test, apply insulating material tightly so
that there is no gap.
WARNING
7RDYRLGULVNRI¿UHÀDUHFRQQHFWLRQVKRXOGEHLQVWDOOHGRXWGRRUV
5HXVDEOHPHFKDQLFDOFRQQHFWRUVDQGÀDUHGMRLQWVDUHQRWDOORZHG
indoors.
WARNING
7RDYRLGULVNRI¿UHHPEHGRUSURWHFWWKHUHIULJHUDQWSLSLQJ
([WHUQDOGDPDJHRQWKHUHIULJHUDQWSLSLQJFDQEHFDXVHRI¿UH
Be sure to use wall hole
sleeve (C) to prevent in-
door/outdoor connecting
wire (A) from contacting
metal parts in the wall
and to prevent damage by
rodents in case the wall
is hollow.
Indoor unit
Wall hole
sleeve (C)
Cut off the
extra length.
3LSH¿[LQJEDQG(
Wall hole cover (D)
Seal the wall hole gap
with putty (H).
Fix the pipe to wall
ZLWKSLSH¿[LQJEDQG
(E).
Fixing screw (F)
(9)
(I)
PARTS TO BE PROVIDED AT YOUR SITE
(A) Indoor/outdoor unit connecting wire*1
1
(B) Extension pipe
1
(C) Wall hole sleeve
1
(D) Wall hole cover
1
(E)
3LSH¿[LQJEDQG
2 to 5
(F) Fixing screw for (E) 4 × 20 mm
2 to 5
(G) Piping tape
1
(H) Putty
1
(I)
Drain hose
(or soft PVC hose, 15 mm inner
diameter or hard PVC pipe VP16)
1 or 2
(J) Refrigeration oil
1
(K) Power supply cord*1
1
ACCESSORIES
Check the following parts before installation.
<Indoor unit>
(1) Installation plate
1
(2)
,QVWDOODWLRQSODWH¿[LQJVFUHZ
4 × 25 mm
7
(3) Wireless remote controller
1
(4)
Felt tape
(For left or left-rear piping)
1
(5) Remote controller holder
1
(6)
Fixing screw for (5) 3.5 × 16 mm
(Black)
2
(7) Battery (AAA) for (3)
2
(8)
$LUFOHDQLQJ¿OWHU
2
<Outdoor unit>
(9) Drain socket
1
Air inlet