WIRELESS REMOTE CONTROLLER
MSZ-GF60VE MSZ-GF71VE
MICROPROCESSOR CONTROL
9
NOTE
: Last setting will be stored after the unit is turned OFF with the remote controller. Indoor unit receives the signal of the
remote controller with beeps.
Signal transmitting section
Operation display section
Temperature buttons
OPERATE/STOP
(ON/OFF) button
Indication of
remote controller
model is on back
FAN SPEED CONTROL button
OPERATION SELECT button
ECONO COOL button
POWERFUL button
CLOCK SET button
WIDE VANE CONTROL button
LONG button
WEEKLY TIMER
set button
TIME, TIMER set buttons
FORWARD button
BACKWARD button
RESET button
i-save button
VANE CONTROL button
Operation Indicator lamp
The operation indicator at the right side of the indoor unit indicates the operation state.
•The following indication applies regardless of shape of the indication.
Indication
Operation state
Room temperature
The unit is operating to
reach the set temperature
About 2°C or more away
from set temperature
The room temperature is
approaching the set tem-
perature
About 1 to 2°C from set
temperature
Standby mode
(Only during multi system
operation)
-
INDOOR UNIT DISPLAY SECTION
Lighted
Blinking
Not lighted
9-1. COOL ( ) OPERATION
(1) Press OPERATE/STOP (ON/OFF) button.
OPERATION INDICATOR lamp of the indoor unit turns on with a beep tone.
(2) Select COOL mode with OPERATION SELECT button.
(3) Press TEMPERATURE buttons (TEMP or button) to select the desired temperature. The setting range is 16 - 31°C.
1. Coil frost prevention
The compressor operational frequency is controlled by the temperature of the indoor heat exchanger to prevent the coil
from frosting.
When the temperature of indoor heat exchanger becomes too low, the coil frost prevention mode works.
The indoor fan operates at the set speed and the compressor stops. This mode continues until the temperature of indoor
heat exchanger rises.
2. Low outside temperature operation
When the outside temperature is lower, low outside temperature operation starts, and the outdoor fan slows or stops.
3. Indoor fan speed control
When the thermostat turns OFF, the indoor fan stops running to reduce power consumption.
After that, the indoor fan stops for 60 seconds and then operates at Very Low for 10 seconds to sense accurate room
temperature. The indoor fan alternates ON and OFF at this interval while the thermostat is OFF.
When the room temperature rises and the thermostat is ON, the indoor fan starts running according to the settings on
the remote controller.