● OPERATING INSTRUCTIONS ●

Even if these items are checked, when the unit does not recover from the 
trouble, stop using the air conditioner and consult your dealer.

Symptom

Explanation & Check points

Indoor Unit

The unit cannot be operated.

•  Is the breaker turned on?

•  Is the power supply plug connected?

•  Is the ON timer set? 

 Page 7 

All LED lamps on the indoor 

unit are blinking.

•  Are the horizontal vanes installed correctly? 

 Page 8 

The horizontal vane does not 
move.

•  Are the horizontal vane and the vertical vane 

installed correctly? 

 Page 8 

•  Is the fan guard deformed?

The unit cannot be operated 

for about 3 minutes when 

restarted.

•  This protects the unit according to instruc-

tions  from  the  microprocessor.  Please 

wait.

Mist is discharged from the air 
outlet of the indoor unit.

•  The cool air from the unit rapidly cools mois-

ture in the air inside the room, and it turns 
into mist.

The swing operation of the 

HORIZONTAL VANE is 

suspended for a while, then 

restarted.

•  This is for the swing operation of the HORI-

ZONTAL VANE to be performed normally.

The air fl ow direction changes 

during operation.
The direction of the horizontal 

vane cannot be adjusted with 

the remote controller.

•  When the unit is operated in COOL or DRY 

mode,  if  the  operation  continues  with  air 

blowing down for 0.5 to 1 hour, the direction 

of the air fl ow is automatically set to position 

(1) to prevent water from condensing and 

dripping.

•  In the heating operation, if the air fl ow tem-

perature is too low or when defrosting is be-

ing done, the horizontal vane is automatically 
set to horizontal position.

The operation is stopped for 
about 10 minutes in the heat-
ing operation.

•  Defrosting  of  the  outdoor  unit  is  being 

done.

  Since this is completed in max.10 minutes, 

please wait. (When the outside temperature 

is too low and humidity is too high, frost is 

formed.)

The unit starts operation by 

itself when the main power 

is turned on, though it isn’t 

operated with the remote 

controller.

•  These models are equipped with an auto re-

start function. When the main power is turned 

off without stopping the unit with the remote 

controller  and  is  turned  on  again,  the  unit 
starts  operation  automatically  in  the  same 

mode as the one set with the remote control-

ler just before the shutoff of the main power. 

Refer to “Auto restart function” 

 page 5 

.

The operation does not stop, 

or air is blown even when the 

ON/OFF button is pressed.

•  Is  the  CLEAN  lamp  lighted?  When  the 

CLEAN  lamp  is  lighted,  CLEAN  operation 
is performed. 

 Page 7 

CLEAN lamp is lighted.

•  CLEAN operation is performed. 

 Page 7 

Multi system

The indoor unit which is not 

operating becomes warm and 

a sound, similar to water fl ow-

ing, is heard from the unit.

•  A small amount of refrigerant continues to 

fl ow into the indoor unit even though it is 

not operating.

When heating operation is 
selected, operation does not 

start right away.

•  When operation is started during defrosting 

of outdoor unit is done, it takes a few minutes 

(max. 10 minutes) to blow out warm air.

Outdoor Unit

The fan of the outdoor unit 
does not rotate even though 
the compressor is running. 
Even if the fan starts to rotate, 
it stops soon.

•  When the outside temperature is low dur-

ing  cooling  operation,  the  fan  operates 

intermittently to maintain suffi cient cooling 

capacity.

Water leaks from the outdoor 

unit.

•  During COOL and DRY operations, pipe or 

pipe connecting sections are cooled and this 

causes water to condense.

•  In the heating operation, water condensed 

on the heat exchanger drips down.

•  In the heating operation, the defrosting op-

eration makes water frozen on the outdoor 

unit melt and drip down.

Symptom

Explanation & Check points

Outdoor Unit

White smoke is discharged 

from the outdoor unit.

•  In  the  heating  operation,  vapor  generated 

by the defrosting operation looks like white 

smoke.

Remote controller

The display on the remote 
controller does not appear 
or it is dim. The indoor unit 
does not respond to the 
remote control signal.

•  Are the batteries exhausted? 

 Page 3 

•  Is the polarity (+, -) of the batteries correct?

 Page 3 

•  Are any buttons on the remote controller of 

other electric appliances being pressed?

Does not cool or heat

The room cannot be cooled 

or heated suffi ciently.

•  Is  the  temperature  setting  appropriate? 

 Page 5 

•  Is  the  fan  setting  appropriate?  Please 

change fan speed to higher setting. 

   

 Page 6 

•  Are the fi lters clean? 

 Page 8 

•  Is the fan or heat exchanger of the indoor unit 

clean? 

 Page 8 

•  Are there any obstacles blocking the air inlet 

or outlet of the indoor or outdoor unit?

•  Is a window or door open?

The room cannot be cooled 

suffi ciently.

•  When  a  ventilation  fan  or  a  gas  cooker  is 

used in a room, the cooling load increases, 

resulting in an insuffi cient cooling effect.

•  When  the  outside  temperature  is  high,  the 

cooling effect may not be suffi cient.

The room cannot be heated 

suffi ciently.

•  When  the  outside  temperature  is  low,  the 

heating effect may not be suffi cient.

Air does not blow out soon in 

the heating operation.

•  Please wait as the unit is preparing to blow 

out warm air.

Airfl ow

The air from the indoor unit 
smells strange.

•  Are the fi lters clean? 

 Page 8 

•  Is the fan or heat exchanger of the indoor unit 

clean? 

 Page 8 

•  The unit may suck in an odor adhering to the 

wall, carpet, furniture, cloth, etc. and blow it 

out with the air.

•  During  PLASMA  operation,  you  may  smell 

ozone  that  is  generated  in  small  quantities 
from the plasma electrode unit. This is not a 
malfunction.

Sound

Cracking sound is heard.

•  This sound is generated by the expansion/

contraction  of  the  front  panel,  etc.  due  to 
change in temperature.

“Burbling” sound is heard.

•  This sound is heard when the outside air is 

absorbed from the drain hose by turning on 

the range hood or the ventilation fan, making 

water fl owing in the drain hose to spout out.

  This sound is also heard when the outside air 

blows into the drain hose in case the outside 

wind is strong.

Mechanical sound is heard 
from the indoor unit.

•  This is the switching sound in turning on/off 

the fan or the compressor.

The sound of water fl owing 

is heard.

•  This is the sound of refrigerant or condensed 

water fl owing in the unit.

Hissing sound is sometimes 

heard.

•  This is the sound when the fl ow of refrigerant 

inside the unit is switched.

In the following cases, stop using the air conditioner and consult your dealer.

•  When water leaks or drips from the indoor unit.

•  When the POWER lamp blinks.

•  When the breaker trips frequently.

•  The remote control signal is not received in a room where an electronic ON/OFF 

type fl uorescent lamp (inverter-type fl uorescent lamp, etc.) is used.

•  Operation of the air conditioner interferes with radio or TV reception. An ampli-

fi er may be required for the affected device.

•  When an abnormal sound is heard.

W

HEN YOU THINK THAT TROUBLE HAS OCCURRED

090616 SG79F259H04.indd   9

2009/07/02   13:01:40

Summary of Contents for MSZ-FB25VA

Page 1: ...IT TYPE AIR CONDITIONERS INDOOR UNIT MSZ FB25VA MSZ FB35VA MSZ FB50VA English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating in structions before use ...

Page 2: ... conditions Do not insert your finger a stick or other objects into the air inlet or outlet This may cause injury since the fan inside rotates at high speeds during operation In case of an abnormal condition such as a burning smell stop the air conditioner and disconnect the power plug or turn the breaker OFF A continued operation in the abnormal state may cause a malfunction fire or electric shock ...

Page 3: ...e breaker OFF when you hear thunder and there is a possibility of a lightning strike The unit may be damaged if lightning strikes After the air conditioner is used for several seasons per form inspection and maintenance in addition to normal cleaning Dirt or dust in the unit may create an unpleasant odor or clog the drain passage and cause water to leak from the indoor unit Consult your dealer for...

Page 4: ...age 7 FAN speed control button Page 6 Off timer button Page 7 On timer button Page 7 VANE control button Page 6 TIME set buttons Pages 3 7 Increase time Decrease time CLOCK button Page 3 RESET button Page 3 Lid Slide down to open Install the remote control ler holder in a place where the signal can be received by the indoor unit Only use the remote controller provided with the unit Do not use othe...

Page 5: ...c is more than 50 cm to the left and right Right Distance to objects wall cabinet etc is less than 50 cm to the right Area Left Center Right Slide switch Remote controller display Press to activate i see control operation Press gently using a thin instrument lights Operation display section The default setting is active Press again to release i see control operation Slide switch i see control oper...

Page 6: ...igh Auto restart function If a power failure occurs or the main power is turned off during operation Auto restart function automatically starts operation in the same mode as the one set with the remote controller just before the shutoff of the main power When timer is set timer setting is cancelled and the unit starts operation when power is resumed If you do not want to use this function please c...

Page 7: ...indoor unit when set to AUTO Press to select horizontal airflow direction Each press changes airflow direction in the following order AUTO Low Med High Super High AUTO 1 2 3 4 5 SWING SWING Vertical airflow direction AUTO The vane is set to the most efficient airflow direction COOL DRY horizontal position HEAT downward position Manual For efficient air conditioning select upper position for COOL DRY a...

Page 8: ...p turns on Display section Press again to cancel PLASMA operation What is PLASMA operation Plasma operation consists of deodorizing and air purifying features Particles of odor releasing substances are absorbed and decomposed by the plasma deodorizing filter Particles of allergens such as pollens and house dust are collected by the plasma anti allergy filter These filters work with negative ions gene...

Page 9: ... a new air cleaning filter Parts Number MAC 307FT E Air outlet and Fan before cleaning make sure that the fan is stopped Air filter Clean every 2 weeks Remove dirt by a vacuum cleaner or rinse with water Dry it well in shade CLEANING 1 Turn the horizontal vanes downward Then remove the upper vane as shown in and Repeat and for the lower vane 2 Swing out the two vertical vanes one by one 4 Put the ve...

Page 10: ...ng capacity Water leaks from the outdoor unit During COOL and DRY operations pipe or pipe connecting sections are cooled and this causes water to condense In the heating operation water condensed on the heat exchanger drips down In the heating operation the defrosting op eration makes water frozen on the outdoor unit melt and drip down Symptom Explanation Check points Outdoor Unit White smoke is d...

Page 11: ...event the effects of a fluorescent lamp keep as far apart as possible wall etc Inverter type fluorescent lamp Keep a space to prevent the pic ture distortion or the noise 1 m or more Radio 100 mm or more Well ventilated dry place 200 500 mm or more TV Cordless phone or Portable phone 3 m or more 1 m or more The installation location of the outdoor unit should be at least 3 m away from the antennas f...

Page 12: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN SG79F259H04 ...

Reviews: