En-1

● OPERATING INSTRUCTIONS ●

 WARNING

Do not connect the power cord to an intermediate point, 
use an extension cord, or connect multiple devices to a 
single AC outlet.

•  This may cause overheating, fi re, or electric shock.

Make sure the power plug is free of dirt and insert it se-
curely into the outlet.

•  A dirty plug may cause fi re or electric shock.

Do not bundle, pull, or modify the power cord, and do not 
apply heat or place heavy objects on it.

•  This may cause fi re or electric shock.

Do not turn the breaker OFF/ON or disconnect/connect the 
power plug during operation.

•  This may create sparks, which can cause fi re.

•  After the indoor unit is switched OFF with the remote con-

troller, make sure to turn the breaker OFF or disconnect the 

power plug. 

Do not expose your body directly to cool air for a prolonged 
length of time.

•  This could be detrimental to your health.

The  unit  should  not  be  installed,  relocated,  or  repaired 
by the user.

•  An  improperly  handled  air  conditioner  may  cause  fi re  or 

electric shock.

This appliance is not intended for use by persons (includ-
ing  children)  with  reduced  physical,  sensory  or  mental 
capabilities, or lack of experience and knowledge, unless 
they have been given supervision or instruction concern-
ing use of the appliance by a person responsible for their 
safety.

Children should be supervised to ensure that they do not 
play with the appliance.

•  Since rotating parts and parts which could cause an electric shock are used 

in this product, be sure to read these “Safety Precautions” before use.

•  Since the cautionary items shown here are important for safety, be sure to 

observe them.

•  After reading this manual, keep it together with the installation manual in a 

handy place for easy reference.

•  Be  sure  to  receive  a  guarantee  card  from  your  dealer  and  check  that  the 

purchased date and shop name, etc. are entered correctly.

Marks and their meanings

 WARNING :

Incorrect  handling  could  cause  serious  hazard,  such  as 

death, serious injury, etc. with a high probability.

 CAUTION :

Incorrect handling could cause serious hazard depending 
on the conditions.

  

Do not insert your fi nger, a stick, or other objects into the 

air inlet or outlet.

•  This may cause injury, since the fan inside rotates at high 

speeds during operation.

  

In case of an abnormal condition (such as a burning smell), 
stop the air conditioner and disconnect the power plug or 
turn the breaker OFF.

•  A continued operation in the abnormal state may cause a 

malfunction, fi re, or electric shock. In this case, consult your 

dealer.

When the air conditioner does not cool or heat, there is 
a  possibility  of  refrigerant  leakage.  In  this  case,  consult 
your dealer. If a repair involves recharging the unit with 
refrigerant, ask the service technician for details.

•  The refrigerant used in the air conditioner is safe. Normally, 

it does not leak. However, if refrigerant leaks and comes in 

contact with a heat source such as a fan heater, kerosene 

heater, or cooking stove, it will create a harmful gas.

 CAUTION

Do  not  touch  the  air  inlet  or  the  aluminum  fi ns  of  the 

indoor/outdoor unit.

•  This may cause injury.

Do not use insecticides or fl ammable sprays on the unit.

•  This may cause a fi re or deformation of the unit.

Do not expose pets or houseplants to direct airfl ow.

•  This may cause injury to the pets or plants.

Do not place other electric appliances or furniture under 
the indoor/outdoor unit.

•  Water may drip down from the unit, which may cause damage 

or malfunction.

Do not leave the unit on a damaged installation stand.

•  The unit may fall and cause injury.

Meanings of symbols used in this manual

 :  Be sure not to do.

 :  Be sure to follow the instruction.

 :  Never insert your fi nger or stick, etc.

 :  Never step onto the indoor/outdoor unit and do not put anything on them.

 :  Danger of electric shock. Be careful.

 :  Be sure to disconnect the power supply plug from the power outlet.

 :  Be sure to shut off the power.

S

AFETY PRECAUTIONS

C

ONTENTS

 

SAFETY PRECAUTIONS 

1

 

NAME OF EACH PART 

3

 

PREPARATION BEFORE OPERATION 

3

 AREA SETTING 

4

 

SELECTING OPERATION MODES

 

5

 

FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT

 

6

 

ECONO COOL OPERATION 

 

7

 

TIMER OPERATION (ON/OFF TIMER)

 

7

■ 

PLASMA OPERATION 

7

■ 

CLEAN OPERATION 

7

 CLEANING 

8

 

WHEN YOU THINK THAT TROUBLE HAS OCCURRED

 

9

 

WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME

 

10

 

INSTALLATION PLACE AND ELECTRICAL WORK

 

10

 

SPECIFICATIONS

 

10

090616 SG79F259H04.indd   1

2009/07/02   13:01:17

Summary of Contents for MSZ-FB25VA

Page 1: ...IT TYPE AIR CONDITIONERS INDOOR UNIT MSZ FB25VA MSZ FB35VA MSZ FB50VA English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating in structions before use ...

Page 2: ... conditions Do not insert your finger a stick or other objects into the air inlet or outlet This may cause injury since the fan inside rotates at high speeds during operation In case of an abnormal condition such as a burning smell stop the air conditioner and disconnect the power plug or turn the breaker OFF A continued operation in the abnormal state may cause a malfunction fire or electric shock ...

Page 3: ...e breaker OFF when you hear thunder and there is a possibility of a lightning strike The unit may be damaged if lightning strikes After the air conditioner is used for several seasons per form inspection and maintenance in addition to normal cleaning Dirt or dust in the unit may create an unpleasant odor or clog the drain passage and cause water to leak from the indoor unit Consult your dealer for...

Page 4: ...age 7 FAN speed control button Page 6 Off timer button Page 7 On timer button Page 7 VANE control button Page 6 TIME set buttons Pages 3 7 Increase time Decrease time CLOCK button Page 3 RESET button Page 3 Lid Slide down to open Install the remote control ler holder in a place where the signal can be received by the indoor unit Only use the remote controller provided with the unit Do not use othe...

Page 5: ...c is more than 50 cm to the left and right Right Distance to objects wall cabinet etc is less than 50 cm to the right Area Left Center Right Slide switch Remote controller display Press to activate i see control operation Press gently using a thin instrument lights Operation display section The default setting is active Press again to release i see control operation Slide switch i see control oper...

Page 6: ...igh Auto restart function If a power failure occurs or the main power is turned off during operation Auto restart function automatically starts operation in the same mode as the one set with the remote controller just before the shutoff of the main power When timer is set timer setting is cancelled and the unit starts operation when power is resumed If you do not want to use this function please c...

Page 7: ...indoor unit when set to AUTO Press to select horizontal airflow direction Each press changes airflow direction in the following order AUTO Low Med High Super High AUTO 1 2 3 4 5 SWING SWING Vertical airflow direction AUTO The vane is set to the most efficient airflow direction COOL DRY horizontal position HEAT downward position Manual For efficient air conditioning select upper position for COOL DRY a...

Page 8: ...p turns on Display section Press again to cancel PLASMA operation What is PLASMA operation Plasma operation consists of deodorizing and air purifying features Particles of odor releasing substances are absorbed and decomposed by the plasma deodorizing filter Particles of allergens such as pollens and house dust are collected by the plasma anti allergy filter These filters work with negative ions gene...

Page 9: ... a new air cleaning filter Parts Number MAC 307FT E Air outlet and Fan before cleaning make sure that the fan is stopped Air filter Clean every 2 weeks Remove dirt by a vacuum cleaner or rinse with water Dry it well in shade CLEANING 1 Turn the horizontal vanes downward Then remove the upper vane as shown in and Repeat and for the lower vane 2 Swing out the two vertical vanes one by one 4 Put the ve...

Page 10: ...ng capacity Water leaks from the outdoor unit During COOL and DRY operations pipe or pipe connecting sections are cooled and this causes water to condense In the heating operation water condensed on the heat exchanger drips down In the heating operation the defrosting op eration makes water frozen on the outdoor unit melt and drip down Symptom Explanation Check points Outdoor Unit White smoke is d...

Page 11: ...event the effects of a fluorescent lamp keep as far apart as possible wall etc Inverter type fluorescent lamp Keep a space to prevent the pic ture distortion or the noise 1 m or more Radio 100 mm or more Well ventilated dry place 200 500 mm or more TV Cordless phone or Portable phone 3 m or more 1 m or more The installation location of the outdoor unit should be at least 3 m away from the antennas f...

Page 12: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN SG79F259H04 ...