background image

En-4

 AUTO mode (Auto change over)

The unit selects the operation mode according to the difference between the 
room temperature and the set temperature. During AUTO mode, the unit 
changes mode (COOL↔HEAT) when the room temperature is 2°C away 
from the set temperature for more than 15 minutes.

 COOL  mode

Enjoy cool air at your desired temperature. 

Note: 

Do not operate COOL mode at very low outside temperatures (less than 
-10°C). Water condensed in the unit may drip and wet or damage furni-
ture, etc.

 DRY mode

Dehumidify your room. The room may be cooled slightly. 
Temperature cannot be set during DRY mode.

 HEAT mode

Enjoy warm air at your desired temperature.

Operation indicator lamp

Emergency operation

When the remote controller cannot be used...

Emergency operation can be activated by pressing the emergency operation 
switch (E.O.SW) on the indoor unit.

Each time the E.O.SW is pressed, the operation changes in 
the following order:

1

Press 

 to start the operation.

2

Press 

 to select operation mode. Each press 

changes mode in the following order:

3

Press 

 or 

 to set the temperature.

Each press raises or lowers the temperature by 1°C.

 

Press 

 to stop the operation.

•  The same setting is selected the next time by simply pressing

 

.

Auto restart function

If a power failure occurs or the main power is turned off during operation, “Auto 
restart function” automatically starts operation in the same mode as the one set 

with

 

the remote controller

 just before the shutoff of the main power. When 

timer is set, timer setting is cancelled and the unit starts operation when power 
is resumed.

If you do not want to use this function, please consult the service repre-
sentative because the setting of the unit needs to be changed.

S

ELECTING OPERATION MODES

Set temperature : 24°C
Fan speed : Medium
Horizontal vane : Auto

(AUTO) (COOL) (DRY)  (HEAT)

Emergency COOL

Emergency HEAT

Stop

Note:

The fi rst 30 minutes of operation is test run. Temperature 
control does not work, and fan speed is set to High.

Multi system operation

Two or more indoor units can be operated by one outdoor unit. When several 
indoor units are operated simultaneously, cooling and heating operations can-
not be done at the same time. When COOL is selected with one unit and HEAT 
with another or vice versa, the unit operated later becomes standby mode. The 
power lamp blinks (display section).

Operation indicator lamp

The operation indicator lamp shows the operation state of the unit.

Indication

Operation state

Room temperature

The unit is operating to reach the set 
temperature

About 2°C or more  
away from set tem-
perature

The room temperature is approach-
ing the set temperature

About 1 to 2°C from 
set temperature

Standby mode (only during multi 
system operation)

 Lighted 

 Blinking 

 Not 

lighted

Все каталоги и инструкции здесь:

 http

:

//splitoff.ru/tehn-doc.html

Summary of Contents for MSZ-CGE22VA

Page 1: ...rectamente e com segurança certifique se de que lê estas instruções de operação antes da utilização ΟΔΗΓΙΕΣ ΛΕΙΤΟΥΡΓΙΑΣ Για το χρήστη Για να χρησιμοποιήσετε αυτή τη μονάδα σωστά και με ασφάλεια βεβαι ωθείτε ότι έχετε διαβάσει αυτό το εγχειρίδιο οδηγιών πριν από τη χρή ση LIBRETTO D ISTRUZIONI Per gli utenti Per utilizzare correttamente ed in tutta sicurezza questo apparecchio leggere il presente li...

Page 2: ... electric shock injury or water leakage etc Consult your dealer If the power supply cord is damaged it must be replaced by the manufacturer or its service agent in order to avoid a hazard When installing relocating or servicing the unit make sure that no substance other than the specified refrigerant R410A enters the refrigerant circuit Any presence of foreign substance such as air can cause abnorm...

Page 3: ... at high speeds during operation When the unit will be unused for a long time disconnect the power plug or turn the breaker OFF The unit may accumulate dirt which may cause overheating or fire Replace all batteries of the remote controller with new ones of the same type Using an old battery together with a new one may cause overheat ing leakage or explosion If the battery fluid comes in contact with...

Page 4: ...uttons to set the time Each press increases decreases the time by 1 minute 10 minutes when pressed longer Indoor unit Remote controller Outdoor units may be different in appearance 1 Remove the front lid 2 Insert AAA alkaline batteries 3 Install the front lid 4 Press RESET Air cleaning filter Anti Allergy Enzyme Filter option Remote controller holder Signal transmitting section Distance of signal A...

Page 5: ...ff during operation Auto restart function automatically starts operation in the same mode as the one set with the remote controller just before the shutoff of the main power When timer is set timer setting is cancelled and the unit starts operation when power is resumed If you do not want to use this function please consult the service repre sentative because the setting of the unit needs to be ch...

Page 6: ...ne manually before starting operation 1 Press during COOL ECONO COOL or HEAT mode to select i save mode 2 Set the temperature fan speed and air flow direction The same setting is selected from the next time by simply pressing Two groups of setting can be saved One for COOL ECONO COOL one for HEAT Select the appropriate temperature fan speed and airflow direction according to your room Normally the ...

Page 7: ... to perform cooling operation with keeping comfort As a result energy can be saved 1 Press or during operation to set the timer ON timer The unit turns ON at the set time OFF timer The unit turns OFF at the set time or blinks Make sure that the current time is set correctly Page 3 2 Press Increase and Decrease to set the time of timer Each press increases or decreases the set time by 10 minutes Se...

Page 8: ...old the hinges and pull to remove as shown in the above illustration Wipe with a soft dry cloth or rinse it with water Do not soak it in water for more than two hours Dry it well in shade 3 Install the panel by following the removal proce dure in reverse Close the front panel securely and press the positions indicated by the arrows Hole Hinge Air cleaning filter Anti Allergy Enzyme Filter option Ba...

Page 9: ...cooling capacity Water leaks from the outdoor unit During COOL and DRY operations pipe or pipe connecting sections are cooled and this causes water to condense In the heating operation water condensed on the heat exchanger drips down In the heating operation the defrosting op eration makes water frozen on the outdoor unit melt and drip down White smoke is discharged from the outdoor unit In the he...

Page 10: ...ower sup ply plug 4 Remove all batteries from the remote controller When using the air conditioner again 1 Clean the air filter Page 7 2 Check that the air inlet and outlet of the indoor and outdoor units are not blocked 3 Check that the earth is connected correctly WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME Indoor Outdoor MUZ GE25 35 42 50VA MUZ GE25 35 42 50VAH Cooling Upper...

Page 11: ...й разборка или ремонт блока не должны осуществляться пользователем Неправильное обращение с кондиционером может привести к возникновению пожара поражению электротоком травмам и подтеканию воды Проконсультируйтесь с дилером При наличии повреждения в шнуре питания его следует заменить у производителя или его сервисного представителя во избежание опасной ситуации При установке перемещении или техобсл...

Page 12: ...ой может произойти перегрев утечка или взрыв Если электролит попадет на вашу кожу или одежду тщательно смойте его чистой водой Если электролит попадет в глаза тщательно промойте их чистой водой и сразу же обратитесь к врачу Убедитесь что место хорошо вентилируется при работе блока с легковоспламеняющимися приборами Недостаточная вентиляция может привести к кислородному голо данию Установите выключ...

Page 13: ... кнопки TIME чтобы установить время При каждом нажатии происхо дит увеличение уменьшение времени на 1 минуту 10 минут при длительном нажатии Внутренний прибор Пульт дистанционного управления Внешний вид устройств предназначенных для использования на улице может отличаться 1 Снимите переднюю крышку 2 Вставьте ще лочные бата рейки типа AAA 3 Установите переднюю крышку 4 Нажмите кнопку RESET Фильтр о...

Page 14: ...ние прибора было выключено во вре мя его работы функция повторного автозапуска автоматически настраивает прибор на работу в том режиме который был задан с помощью пульта дистанционного управления до отключения электропитания Когда таймер установлен настройка таймера отменяется и блок начинает работу при возобновлении подачи питания Если вы не хотите пользоваться этой функцией обратитесь к представ...

Page 15: ...еред запуском операции переместите вертикальную заслонку вручную 1 Для выбора режима i save нажмите во время работы кондиционера в режимах COOL ECONO COOL или HEAT 2 Задайте температуру скорость вентилятора и на правление воздушного потока Эта же настройка выбирается в следующий раз путем нажатия Можно сохранять две группы настроек Одну для режима COOL ECONO COOL а вторую для режима HEAT Выберите ...

Page 16: ...возможность осуществления операции охлаждения и поддерживаются комфортные условия В результате можно экономить электроэнергию 1 Во время операции нажмите или чтобы установить таймер таймер ВКЛЮЧЕНИЯ В заданное время прибор ВКЛЮЧИТСЯ таймер ВЫКЛЮЧЕНИЯ В заданное время при бор ВЫКЛЮЧИТСЯ или мигает Убедитесь что время задано правильно Стр 3 2 Нажмите Увеличить и Уменьшить что бы задать время таймера...

Page 17: ...ь до тех пор пока она не зафиксируется на месте со щелчком 2 Придерживайте петли и тяните чтобы снять как показано на иллюстрации выше Протирайте мягкой сухой тканью или промывайте водой Не держите ее в воде более двух часов Сушите изделия в тени надлежащим образом 3 Устанавливайте переднюю панель выполняя инс трукции по ее снятию в обратном порядке Надежно закройте переднюю панель и нажмите на об...

Page 18: ...туре наружного воздуха вентилятор может включаться и выключаться чтобы поддерживать достаточную мощность охлаждения Из наружного прибора выте кает вода При работе в режимах COOL ОХЛАЖ ДЕНИЕ и DRY СУШКА происходит охлаждение труб и трубных соединений что вызывает конденсацию влаги При работе в режиме обогрева конденсат образовавшийся на теплообменнике стекает вниз При работе в режиме обогрева во вр...

Page 19: ...луатации Охлаждение Внутренний 27 C DB 19 C WB Наружный 35 C DB Обогрев Внутренний 20 C DB Наружный 7 C DB 6 C WB 2 Отдельное использование CGE22 не предусмотрено Данная модель внутреннего прибора предназначена только для мульти системного кондиционера По вопросам технических характеристик мультисистемной моде ли обратитесь к своему дилеру и или см каталог Гарантированный рабочий диапазон DB сухой...

Page 20: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN SG79F301H04 Все каталоги и инструкции здесь http splitoff ru tehn doc html ...