background image

9

WHEN THE AIR CONDITIONER IS NOT GOING TO BE
USED FOR A LONG TIME

When it is not going to be used for a long
time:

1

Perform the FAN operation for 3 or 4 hours
to dry the inside of the air conditioner.

To perform FAN operation, set the remote control-
ler to the highest temperature in the MANUAL COOL
mode. (Refer to page 7.)

2

Turn off the breaker and/or disconnect the
power supply plug.

 CAUTION:

Turn off the breaker or disconnect the power supply plug
when the air conditioner is not going to be used for a
long time.
Dirt may collect and this may cause a fire.

3

Remove the batteries from the remote con-
troller.

 CAUTION:

To prevent liquid leakage, take out all batteries when the
remote controller is not going to be used for a long time.

When the air conditioner is to be used
again:

1

Clean the air filter and install it in the indoor
unit.

(Refer to page 10 for cleaning instructions.)

2

Check that the air inlet and outlet of the in-
door/outdoor units are not blocked with any
obstacles.

3

Check that the earth is connected correctly.

 CAUTION:

Earth the unit.
Do not connect the earth to a gas pipe, water pipe, light-
ning rod or the earth of a telephone. If the earthing is
incorrect, it may cause an electric shock.

MAINTENANCE

Before starting maintenance

Turn off the breaker and/or disconnect the
power supply plug.

CAUTION:

When the unit is to be cleaned, switch it off and discon-
nect the power supply plug or turn off the breaker. Since
the fan rotates at high speed during operation, it may
cause an injury.

Cleaning the indoor unit

Clean the unit using a soft dry cloth.

If the dirt is noticeable, wipe the unit with a cloth
soaked in a solution of mild detergent diluted in luke-
warm water.

Do not use gasoline, benzine, polishing powder, or
insecticide. The unit may be damaged.

The front panel may come off if it is lifted up past its
level position. If the front panel comes off, refer to
step 

3

 in CLEANING THE FRONT PANEL ex-

plained on the right.

Front panel

1

Hold both ends of the front panel, lift the
panel up until its level, and then pull it to-
wards you.

 CAUTION:

• Do not drop the front panel or pull it out forcibly.

The panel may be damaged.

• Do not step onto an unstable bench when removing or

installing the front panel.
This may cause an injury, etc. if you fall down.

2

Wipe the front panel with a soft dry cloth or
wash it with water.
After washing the panel, wipe up the remain-
ing water with a soft dry cloth and let it dry
out of direct sunlight.

If the dirt is noticeable, wipe the front panel with a
cloth soaked in a solution of mild detergent diluted
in lukewarm water.

Do not use gasoline, benzine, thinner, polishing
powder, or insecticide and do not wash the front
panel with a scrubbing brush or the hard surface of
a sponge.

Do not soak the front panel in water/lukewarm wa-
ter longer than two hours and do not expose the
panel to direct sunlight, heat, or flames when dry-
ing it. The panel may be deformed or discolored.

3

Hold both ends of the front panel, keep the
panel level, and insert the hinges into the
holes on the upper part of the indoor unit
until they click into place. (

1

) Then, close

the front panel securely. (

2

)

1

2

Keep the panel level and insert
the hinges into the holes.

CLEANING THE FRONT PANEL, HEAT EXCHANGER AND FAN

Hinge

Hole

Heat exchanger

You can sweep the surface of heat exchanger if you install
the special-made brush to your vacuum cleaner. Please re-
fer to the instructions described in Quick Clean Kit for de-
tails.

WARNING:

• Do not touch the heat exchanger directly with your

hands. Otherwise you may get injured. (It’s recom-
mended to protect your hands with a pair of gloves.)

CAUTION:

• Do not step onto an unstable bench when cleaning.

Otherwise you may fall down and get injured.

• Use only the special-made brush listed below. Do not

use other stuffs. Otherwise the heat exchanger of the
indoor unit may get damaged.

Optional product

Name of parts

Quick Clean Kit

Parts number

MAC-093SS-E

Optional product is available from your local dealer.

NOTE:
Only available for the hose diameter of vacuum cleaner 

:

32 - 39 mm (inside diameter).

Fan

Refer to page 11 for cleaning the fan.

Heat exchanger

1

 Pull

3

 Insert

Summary of Contents for MSZ-A09YV SERIES

Page 1: ...r gli utenti Per utilizzare correttamente quest unità leggere questo libretto d istruzioni atten tamente e per intero π π Àƒ π È ÙÔÓ ÂÏ ÙË È Ó ÚËÛÈÌÔ ÔÈ ÛÂÙ ٠ÙËÓ ÌÔÓ ÛˆÛÙ Î È Ì ÛÊ ÏÂÈ Â Èˆı Ù fiÙÈ ÂÙÂ È ÛÂÈ Ùfi ÙÔ ÂÁ ÂÈÚ ÈÔ Ô ËÁÈÒÓ ÚÈÓ fi ÙËÓ Ú ÛË INSTRUÇÕES DE OPERAÇÃO Para os clientes Para utilizar esta unidade correctamente certifique se de que lê estas instruções de operação antes da utiliza...

Page 2: ...ing the unit etc This may cause an injury etc if you fall down Do not pull the power supply cord The core wire of the power supply cord may be disconnected and this may cause a fire Do not charge or disassemble the batteries and do not throw them into a fire This may result in leakage fire or an explosion Do not operate the unit for a long time in high humidity e g leaving a door or window open In...

Page 3: ...ade the insulation This may cause an electric shock Do not step or put anything on the indoor outdoor unit This may cause an injury etc if you or something falls down WARNING Consult your dealer for installation of the air conditioner CAUTION Do not install the unit where flammable gas could leak If gas leaks and collects around the unit it may cause an explosion Earth the unit Do not connect the ...

Page 4: ... because the setting of the unit needs to be changed Auto restart function is When the indoor unit is controlled with the remote controller the operation mode the set temperature and the fan speed are stored in the memory If a power failure occurs or the main power is turned off during operation Auto restart function sets automatically to start operating in the same mode as the one set with the re...

Page 5: ...nce in case of EMERGENCY HEAT MODE or twice in case of EMERGENCY COOL MODE Operation Indicator Operation Indicator Operation Indicator EMERGENCY HEAT EMERGENCY COOL STOP Handling of the remote controller The range that the signal can reach is about 6 m when the remote controller is pointed at the front of the in door unit When a button is pressed one or two beeps will be heard from the indoor unit...

Page 6: ...emperature is 2 C higher than the set temperature the set temperature may not be changed since the air conditioner is operating to reach the target set temperature In this case please wait until the room temperature drops to within 2 C of the set temperature and then change the set temperature HEAT When the room temperature is 2 C lower than the set temperature the set temperature may not be chang...

Page 7: ... in sequence I FEEL AUTO COOL DRY HEAT To stop operation Press the ON OFF button After the operation mode is set once the operation starts in the same mode as the one set previously from the next time by simply pressing the ON OFF button MANUAL OPERATION COOL DRY HEAT ON OFF FAN TOO WARM TOO COOL VANE MODE ECONO COOL STOP START HR MIN AMPM CLOCK C AMPM I FEEL COOL DRY AUTO HEAT RESET CLOCK ON OFF ...

Page 8: ...c How to set the ON timer 1 Press the START button during operation Each time the button is pressed the ON timer mode alternates between ON and OFF 2 Set the time of the timer using the HR and MIN buttons Each time the HR button is pressed the set time in creases by 1 hour each time the MIN button is pressed the set time increases by 10 minutes To release the ON timer Press the START button How to...

Page 9: ...d both ends of the front panel lift the panel up until its level and then pull it to wards you CAUTION Do not drop the front panel or pull it out forcibly The panel may be damaged Do not step onto an unstable bench when removing or installing the front panel This may cause an injury etc if you fall down 2 Wipe the front panel with a soft dry cloth or wash it with water After washing the panel wipe...

Page 10: ...l ter with water If the dirt is noticeable wash the filter with a solu tion of mild detergent diluted in lukewarm water If hot water 50 C or more is used the filter may be deformed Open the front panel then remove replace the filter Catechin air filter Remove Install What is Catechin air filter The air filter is dyed with a natural material catechin that is contained in tea The catechin air filter...

Page 11: ...rmed and the vanes may not work properly Put the vertical vanes back correctly to their original positions Otherwise condensed water may drip down from the indoor unit or the horizontal vanes could malfunction 6 Install the horizontal vanes Reverse the removal procedures Upper vane Lower vane Insert this end first Upper right Insert this end first Lower right After Cleaning Insert the power supply...

Page 12: ... power failure as these models are equipped with an auto restart function the air conditioner should start operating again Refer to Descrip tion of AUTO RESTART FUNCTION on page 6 Question The air flow direction changes during operation The direction of the hori zontal vane cannot be ad justed with the remote con troller Water leaks from the out door unit White smoke is discharged from the outdoor...

Page 13: ...akage or not when repairs are carried out The refrigerant charged in the air conditioner is safe Refrigerant normally does not leak however if refrigerant gas leaks indoors and comes into contact with the fire of a fan heater space heater stove etc harmful substances will be generated Electrical work Provide an exclusive circuit for the power supply of the air conditioner Be sure to observe the br...

Page 14: ...310 JAPAN SG79Y280H01 This product is designed and intended for use in the residential commercial and light industrial environment The product at hand is based on the following EU regulations Low Voltage Directive 73 23 EEC Electromagnetic Compatibility Directive 89 336 EEC ...

Page 15: ......

Reviews: