background image

13

INSTALLATION, RELOCATION AND INSPECTION

Installation place

Avoid installing the air conditioner in the following places.

Where flammable gas could leak.

CAUTION:

Do not install the unit where flammable gas could leak.
If gas leaks and collects around the unit, it may cause
an explosion.

Where there is much machine oil.

Salty places such as the seaside.

Where sulfide gas is generated such as a hot spring.

Where oil is splashed or where the area is filled with
oily smoke.

Where there is high-frequency or wireless equipment.

CAUTION:

• Earth the unit.

Do not connect the earth to a gas pipe, water pipe, lightning rod or the earth of a telephone. If the earthing is
incorrect, it may cause an electric shock.

• Install an earth leakage breaker depending on the place where the air conditioner is to be installed (humid places,

etc.).
If the earth leakage breaker is not installed, it may cause an electric shock.

Inspection and maintenance

When the air conditioner is used for several seasons, the capacity may be lowered due to dirt inside the unit.

Depending on the condition, an odor may be generated or dehumidified water may not drain out smoothly due to dirt,
dust, etc.

It is recommended that the unit be inspected and maintained (charged) by specialist in addition to normal maintenance.
Consult your dealer.

Operating sound considerations

Do not put an object around the air outlet of the outdoor unit. This may lower the capacity or increase the volume of the
operating sound.

If an abnormal sound is heard during operation, consult your dealer.

Relocation

When the air conditioner is to be removed or re-installed because of rebuilding, moving, etc., special techniques and work
are required.

 WARNING:

Repairs or relocation should not be done by the customer.
If this is done incorrectly, it may cause a fire, an electric shock, or an injury from the unit falling, water leaking, etc.
Consult your dealer.

Disposal

To dispose of this product, consult your dealer.

If you have any questions, consult your dealer.

WARNING:

If the air conditioner operates but does not cool or heat (depending on model) the room, consult your dealer since
there may be a refrigerant leak. Be sure to ask the service representative whether there is refrigerant leakage or not
when repairs are carried out.
The refrigerant charged in the air conditioner is safe. Refrigerant normally does not leak, however, if refrigerant gas
leaks indoors, and comes into contact with the fire of a fan heater, space heater, stove, etc., harmful substances will be
generated.

Electrical work

Provide an exclusive circuit for the power supply of the air conditioner.

Be sure to observe the breaker capacity.

WARNING :

• The customer should not install this unit.

If installation is done incorrectly, it may cause a fire, an electric shock, or injury from the unit falling, water leaking,
etc.

• Do not use intermediate connection of the power supply cord or the extension cord and do not connect many

devices to one AC outlet.
A fire or an electric shock may result from poor contact, poor insulation, exceeding the permissible current, etc.
Consult your dealer.

SPECIFICATIONS

MSZ-A09YV(H)

MSZ-A12YV(H)

MSZ-A09YV

MSZ-A12YV

MUZ-A09YV(H)

MUZ-A12YV(H)

Cooling

Heating

Cooling

Heating

2.5

3.2

3.5

4.0

0.67

0.84

1.09

1.08

9

10

33

34

0.80

0.90

37/29/21

38/30/21

39/31/22

38/30/22

46

47

48

Set name

Model

Indoor
Outdoor

Function
Power supply
Capacity

kW

Input

kW

Weight

Indoor

kg

Outdoor

kg

Refrigerant filling

kg

capacity (R410A)

IP code

Indoor
Outdoor

Permissible

LP ps

MPa

excessive
operating

HP ps

MPa

pressure

Indoor

dB(A)

Noise level

(High/Med./Low)
Outdoor

dB(A)

~ /N, 230V, 50Hz

IP 20
IP 24

1.64

4.15

NOTE:

1. Rating condition

Cooling —

Indoor:

27°C DB, 19°C WB

Outdoor:

35°C DB

Heating —

Indoor:

20°C DB

Outdoor:

7°C DB, 6°C WB

2. Guaranteed operating range

Indoor

Outdoor

MUZ-A09/A12YV MUZ-A09/A12YVH

Upper limit

32°C DB

46°C DB

46°C DB

Cooling

23°C WB

Lower limit

21°C DB

-10°C DB

-10°C DB

15°C WB

Upper limit

27°C DB

24°C DB

24°C DB

Heating

18°C WB

18°C WB

Lower limit

20°C DB

-10°C DB

-15°C DB

-11°C WB

-16°C WB

To prevent the effects
of a fluorescent lamp,
keep as far apart as
possible.

wall, etc.

Inverter-type
fluorescent lamp

Keep a space
to prevent the
picture
distortion or
the noise.

1 m

or more

Radio

100 mm or
more

Well-
ventilated
dry place

200 mm or
more

TV

Cordless
phone or
Portable
phone

3 m

or more

1 m

or more

The installation location of the outdoor unit should be
at least 3 m away from the antennas for TV sets,
radios, etc. In areas where the reception is weak, pro-
vide greater space between the outdoor unit and the
antenna of the affected device if operation of the air
conditioner interferes with radio or TV reception.

Summary of Contents for MSZ-A09YV SERIES

Page 1: ...r gli utenti Per utilizzare correttamente quest unità leggere questo libretto d istruzioni atten tamente e per intero π π Àƒ π È ÙÔÓ ÂÏ ÙË È Ó ÚËÛÈÌÔ ÔÈ ÛÂÙ ٠ÙËÓ ÌÔÓ ÛˆÛÙ Î È Ì ÛÊ ÏÂÈ Â Èˆı Ù fiÙÈ ÂÙÂ È ÛÂÈ Ùfi ÙÔ ÂÁ ÂÈÚ ÈÔ Ô ËÁÈÒÓ ÚÈÓ fi ÙËÓ Ú ÛË INSTRUÇÕES DE OPERAÇÃO Para os clientes Para utilizar esta unidade correctamente certifique se de que lê estas instruções de operação antes da utiliza...

Page 2: ...ing the unit etc This may cause an injury etc if you fall down Do not pull the power supply cord The core wire of the power supply cord may be disconnected and this may cause a fire Do not charge or disassemble the batteries and do not throw them into a fire This may result in leakage fire or an explosion Do not operate the unit for a long time in high humidity e g leaving a door or window open In...

Page 3: ...ade the insulation This may cause an electric shock Do not step or put anything on the indoor outdoor unit This may cause an injury etc if you or something falls down WARNING Consult your dealer for installation of the air conditioner CAUTION Do not install the unit where flammable gas could leak If gas leaks and collects around the unit it may cause an explosion Earth the unit Do not connect the ...

Page 4: ... because the setting of the unit needs to be changed Auto restart function is When the indoor unit is controlled with the remote controller the operation mode the set temperature and the fan speed are stored in the memory If a power failure occurs or the main power is turned off during operation Auto restart function sets automatically to start operating in the same mode as the one set with the re...

Page 5: ...nce in case of EMERGENCY HEAT MODE or twice in case of EMERGENCY COOL MODE Operation Indicator Operation Indicator Operation Indicator EMERGENCY HEAT EMERGENCY COOL STOP Handling of the remote controller The range that the signal can reach is about 6 m when the remote controller is pointed at the front of the in door unit When a button is pressed one or two beeps will be heard from the indoor unit...

Page 6: ...emperature is 2 C higher than the set temperature the set temperature may not be changed since the air conditioner is operating to reach the target set temperature In this case please wait until the room temperature drops to within 2 C of the set temperature and then change the set temperature HEAT When the room temperature is 2 C lower than the set temperature the set temperature may not be chang...

Page 7: ... in sequence I FEEL AUTO COOL DRY HEAT To stop operation Press the ON OFF button After the operation mode is set once the operation starts in the same mode as the one set previously from the next time by simply pressing the ON OFF button MANUAL OPERATION COOL DRY HEAT ON OFF FAN TOO WARM TOO COOL VANE MODE ECONO COOL STOP START HR MIN AMPM CLOCK C AMPM I FEEL COOL DRY AUTO HEAT RESET CLOCK ON OFF ...

Page 8: ...c How to set the ON timer 1 Press the START button during operation Each time the button is pressed the ON timer mode alternates between ON and OFF 2 Set the time of the timer using the HR and MIN buttons Each time the HR button is pressed the set time in creases by 1 hour each time the MIN button is pressed the set time increases by 10 minutes To release the ON timer Press the START button How to...

Page 9: ...d both ends of the front panel lift the panel up until its level and then pull it to wards you CAUTION Do not drop the front panel or pull it out forcibly The panel may be damaged Do not step onto an unstable bench when removing or installing the front panel This may cause an injury etc if you fall down 2 Wipe the front panel with a soft dry cloth or wash it with water After washing the panel wipe...

Page 10: ...l ter with water If the dirt is noticeable wash the filter with a solu tion of mild detergent diluted in lukewarm water If hot water 50 C or more is used the filter may be deformed Open the front panel then remove replace the filter Catechin air filter Remove Install What is Catechin air filter The air filter is dyed with a natural material catechin that is contained in tea The catechin air filter...

Page 11: ...rmed and the vanes may not work properly Put the vertical vanes back correctly to their original positions Otherwise condensed water may drip down from the indoor unit or the horizontal vanes could malfunction 6 Install the horizontal vanes Reverse the removal procedures Upper vane Lower vane Insert this end first Upper right Insert this end first Lower right After Cleaning Insert the power supply...

Page 12: ... power failure as these models are equipped with an auto restart function the air conditioner should start operating again Refer to Descrip tion of AUTO RESTART FUNCTION on page 6 Question The air flow direction changes during operation The direction of the hori zontal vane cannot be ad justed with the remote con troller Water leaks from the out door unit White smoke is discharged from the outdoor...

Page 13: ...akage or not when repairs are carried out The refrigerant charged in the air conditioner is safe Refrigerant normally does not leak however if refrigerant gas leaks indoors and comes into contact with the fire of a fan heater space heater stove etc harmful substances will be generated Electrical work Provide an exclusive circuit for the power supply of the air conditioner Be sure to observe the br...

Page 14: ...310 JAPAN SG79Y280H01 This product is designed and intended for use in the residential commercial and light industrial environment The product at hand is based on the following EU regulations Low Voltage Directive 73 23 EEC Electromagnetic Compatibility Directive 89 336 EEC ...

Page 15: ......

Reviews: