In the following cases, stop using the air conditioner and consult your dealer.
• When water leaks or drips from the indoor unit.
• When the upper operation indicator lamp blinks.
• When the breaker trips frequently.
• Operation of the air conditioner interferes with radio or TV reception. An amplifi er may be required for the affected device.
• When an abnormal sound is heard.
• When any refrigerant leakage is found.
W
HEN YOU THINK THAT TROUBLE HAS OCCURRED
S
PECIFICATIONS
Note:
Rating condition
Cooling — Indoor:
27°C DB, 19°C WB
Outdoor: 35°C DB
Indoor
Outdoor
Cooling
Upper limit
32°C DB
23°C WB
46°C DB
—
Lower limit
21°C DB
15°C WB
-25°C DB
—
Guaranteed operating range
DB: Dry Bulb
WB: Wet Bulb
Model
Set name
MSY-TP35VF
MSY-TP50VF
Indoor
MSY-TP35VF
MSY-TP50VF
Outdoor
MUY-TP35VF
MUY-TP50VF
Power supply
~ /N, 230 V, 50 Hz
Capacity
kW
3.5
5.0
Input
kW
0.76
1.45
Weight
Indoor
kg
12.5
Outdoor
kg
34
Refrigerant fi lling capacity (R32)
kg
0.85
IP code
Indoor
IP 20
Outdoor
IP 24
Permissible excessive
operating pressure
LP ps
MPa
2.77
HP ps
MPa
4.17
Noise level
Indoor (Super High/High/Med./Low)
dB(A)
45/40/36/31
Outdoor
dB(A)
45
47
JG79Y430L01_01En.indd 5