● OPERATING INSTRUCTIONS ●

Even if these items are checked, when the unit does not recover from the 

trouble, stop using the air conditioner and consult your dealer.

Symptom

Explanation & Check points

Indoor Unit

The unit cannot be operated.

•  Is the breaker turned on?

•  Is the power supply plug connected?

•  Is the ON timer set? 

 Page 5 

All LED lamps on the indoor 

unit are blinking.

•  Is  the  horizontal  vane  installed  correctly? 

 Page 6 

The horizontal vane does not 

move.

•  Are the horizontal vane and the vertical vane 

installed correctly? 

 Page 6 

•  Is the fan guard deformed?

The unit cannot be operated 

for about 3 minutes when 

restarted.

•  This protects the unit according to instruc-

tions  from  the  microprocessor.  Please 

wait.

Mist is discharged from the air 

outlet of the indoor unit.

•  The cool air from the unit rapidly cools mois-

ture in the air inside the room, and it turns 

into mist.

The swing operation of the 

HORIZONTAL VANE is 

suspended for a while, then 

restarted.

•  This is for the swing operation of the HORI-

ZONTAL VANE to be performed normally.

The air fl ow direction changes 

during operation.

The direction of the horizontal 

vane cannot be adjusted with 

the remote controller.

•  When the unit is operated in COOL or DRY 

mode,  if  the  operation  continues  with  air 

blowing down for 0.5 to 1 hour, the direction 

of the air fl ow is automatically set to position 

(1) to prevent water from condensing and 

dripping.

The unit starts operation by 

itself when the main power 

is turned on, though it isn’t 

operated with the remote 

controller.

•  These models are equipped with an auto re-

start function. When the main power is turned 

off without stopping the unit with the remote 

controller and is turned on again, the unit 

starts operation automatically in the same 

mode as the one set with the remote control-

ler just before the shutoff of the main power. 

Refer to “Auto restart function” 

 page 4 

.

Outdoor Unit

The fan of the outdoor unit 

does not rotate even though 

the compressor is running. 

Even if the fan starts to rotate,  

it stops soon.

•  When the outside temperature is low dur-

ing  cooling  operation,  the  fan  operates 

intermittenly  to  maintain  suffi cient  cooling 

capacity.

Water leaks from the outdoor 

unit.

•  During COOL and DRY operations, pipe or 

pipe connecting sections are cooled and this 

causes water to condense.

Symptom

Explanation & Check points

Remote controller

The display on the remote 

controller does not appear 

or it is dim. The indoor unit 

does not respond to the 

remote control signal.

•  Are the batteries exhausted? 

 Page 3 

•  Is the polarity (+, -) of the batteries correct?

 Page 3 

•  Are any buttons on the remote controller of 

other electric appliances being pressed?

Does not cool

The room cannot be cooled  

suffi ciently.

•  Is  the  temperature  setting  appropriate? 

 Page 4 

•  Is  the  fan  setting  appropriate?  Please 

change fan speed to higher setting.

•  Is the fi lter clean? 

 Page 6 

•  Is the fan or heat exchanger of the indoor unit 

clean? 

 Page 6 

•  Are there any obstacles blocking the air inlet 

or outlet of the indoor or outdoor unit?

•  Is a window or door open?

The room cannot be cooled 

suffi ciently.

•  When  a  ventilation  fan  or  a  gas  cooker  is 

used in a room, the cooling load increases, 

resulting in an insuffi cient cooling effect.

•  When  the  outside  temperature  is  high,  the 

cooling effect may not be suffi cient.

Airfl ow

The air from the indoor unit 

smells strange.

•  Is the fi lter clean? 

 Page 6 

•  Is the fan or heat exchanger of the indoor unit 

clean? 

 Page 6 

•  The unit may suck in an odor adhering to the 

wall, carpet, furniture, cloth, etc. and blow it 

out with the air.

Sound

Cracking sound is heard.

•  This sound is generated by the expansion/

contraction  of  the  front  panel,  etc.  due  to 

change in temperature.

“Burbling” sound is heard.

•  This sound is heard when the outside air is 

absorbed from the drain hose by turning on 

the range hood or the ventilation fan, making 

water fl owing in the drain hose to spout out.

  This sound is also heard when the outside air 

blows into the drain hose in case the outside 

wind is strong.

Mechanical sound is heard 

from the indoor unit.

•  This is the switching sound in turning on/off 

the fan or the compressor.

The sound of water fl owing 

is heard.

•  This is the sound of refrigerant or condensed 

water fl owing in the unit.

Hissing sound is sometimes 

heard.

•  This is the sound when the fl ow of refrigerant 

inside the unit is switched.

In the following cases, stop using the air conditioner and consult your 

dealer.

•  When water leaks or drips from the indoor unit.

•  When the upper operation indicator lamp blinks.

•  When the breaker trips frequently.

•  The remote control signal is not received in a room where an electronic ON/OFF 

type fl uorescent lamp (inverter-type fl uorescent lamp, etc.) is used.

•  Operation of the air conditioner interferes with radio or TV reception. An ampli-

fi er may be required for the affected device.

•  When an abnormal sound is heard.

W

HEN YOU THINK THAT TROUBLE HAS OCCURRED

SG79F322H03_en.indd   7

2009/06/26   10:54:49

Summary of Contents for MSY-GC25VA

Page 1: ...SPLIT TYPE AIR CONDITIONERS INDOOR UNIT MSY GC25VA MSY GC35VA English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating in structions before use ...

Page 2: ...handling could cause serious hazard depending on the conditions Do not insert your finger a stick or other objects into the air inlet or outlet This may cause injury since the fan inside rotates at high speeds during operation In case of an abnormal condition such as a burning smell stop the air conditioner and disconnect the power plug or turn the breaker OFF A continued operation in the abnormal ...

Page 3: ...hear thunder and there is a possibility of a lightning strike The unit may be damaged if lightning strikes After the air conditioner is used for several seasons per form inspection and maintenance in addition to normal cleaning Dirt or dust in the unit may create an unpleasant odor con tribute to growth of fungi such as mold or clog the drain pas sage and cause water to leak from the indoor unit C...

Page 4: ...lter Air inlet Heat exchanger Front panel Air cleaning filter Anti Allergy Enzyme Filter Fan guard Outdoor unit NAME OF EACH PART PREPARATION BEFORE OPERATION Indoor unit Remote controller Appearance of the outdoor unit may differ from some models R E S E T C L O C K Make sure the polarity of the batteries is correct Do not use manganese batteries The remote controller could malfunction Do not use ...

Page 5: ...mperature About 1 to 2 C from set temperature Lighted Not lighted Emergency operation When the remote controller cannot be used Emergency operation can be activated by pressing the emergency operation switch E O SW on the indoor unit Each time the E O SW is pressed the operation changes in the following order 1 Press to start the operation 2 Press to select operation mode Each press changes mode i...

Page 6: ...ow direction Move the vertical vane manually before starting operation Press during COOL mode page 4 to start ECONO COOL operation The unit performs swing operation vertically in various cycle according to the temperature of the unit Set temperature is set 2 C higher auto matically Press again to cancel ECONO COOL operation Pressing also cancels ECONO COOL operation What is ECONO COOL Swing air flo...

Page 7: ...st performance and to reduce power consumption Moisture in the air conditioner for a long time contributes to growth of fungi such as mold To prevent fungi growth set to the highest temperature in manual COOL mode and operate for 3 or 4 hours to dry out the inside of the unit Air outlet and Fan before cleaning make sure that the fan is stopped Pull to remove from the air filter Air filter Catechin a...

Page 8: ...ints Remote controller The display on the remote controller does not appear or it is dim The indoor unit does not respond to the remote control signal Are the batteries exhausted Page 3 Is the polarity of the batteries correct Page 3 Are any buttons on the remote controller of other electric appliances being pressed Does not cool The room cannot be cooled sufficiently Is the temperature setting app...

Page 9: ...cent lamp Keep a space to prevent the pic ture distortion or the noise 1 m or more Radio 100 mm or more Well ventilated dry place 100 mm or more TV Cordless phone or Portable phone 3 m or more 1 m or more The installation location of the outdoor unit should be at least 3 m away from the antennas for TV sets radios etc In areas where the reception is weak provide greater space between the outdoor u...

Page 10: ......

Page 11: ......

Page 12: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN SG79F322H03 ...

Reviews: