background image

En-2

 CAUTION

Do not step on an unstable bench to operate or clean the 

unit.

•  This may cause injury if you fall down.

Do not pull the power cord.

•  This may cause a portion of the core wire to break, which may 

cause overheating or fi re.

Do  not  charge  or  disassemble  the  batteries,  and  do  not 

throw them into a fi re.

•  This may cause the batteries to leak, or cause a fi re or explo-

sion.

Do not operate the unit for a long time at high humidity (80% 

RH or more), such as with a door or window left open.

•  The water condensation in the air conditioner may drip down, 

wetting or damaging the furniture.

Do not use the unit for special purposes, such as storing 

food, raising animals, growing plants, or preserving preci-

sion devices or art objects.

•  This may cause deterioration of quality, or harm to animals 

and plants.

Do not expose combustion appliances to direct airfl ow.

•  This may cause incomplete combustion.

Before cleaning the unit, switch it OFF and disconnect the 

power plug or turn the breaker OFF.

•  This may cause injury, since the fan inside rotates at high 

speeds during operation.

When the unit will be unused for a long time, disconnect the 

power plug or turn the breaker OFF.

•  The unit may accumulate dirt, which may cause overheating 

or fi re.

Replace all batteries of the remote controller with new ones 

of the same type.

•  Using  an  old  battery  together  with  a  new  one  may  cause 

overheating, leakage, or explosion.

If the battery fl uid comes in contact with your skin or clothes, 

wash them thoroughly with clean water.

•  If the battery fl uid comes in contact with your eyes, wash them 

thoroughly  with  clean  water  and  immediately  seek  medical 

attention.

Ensure that the area is well-ventilated when the unit is oper-

ated together with a combustion appliance.

•  Inadequate ventilation may cause oxygen starvation.

Turn the breaker OFF when you hear thunder and there is a 

possibility of a lightning strike.

•  The unit may be damaged if lightning strikes.

After the air conditioner is used for several seasons, per-

form  inspection  and  maintenance  in  addition  to  normal 

cleaning.

•  Dirt or dust in the unit may create an unpleasant odor, con-

tribute to growth of fungi, such as mold, or clog the drain pas-

sage, and cause water to leak from the indoor unit. Consult 

your  dealer  for  inspection  and  maintenance,  which  require 

specialized knowledge and skills.

 WARNING

Consult your dealer for installing the air conditioner. 

•  It should not be installed by the user since installation requires 

specialized knowledge and skills. An improperly installed air 

conditioner may cause water leakage, fi re, or electric shock.

Provide a dedicated power supply for the air conditioner.

•  A  non-dedicated  power  supply  may  cause  overheating  or 

fi re.

Do not install the unit where fl ammable gas could leak.

•  If gas leaks and accumulates around the outdoor unit, it may 

cause an explosion.

Earth the unit correctly.

•  Do not connect the earth wire to a gas pipe, water pipe, light-

ning rod, or a telephone ground wire. Improper earthing may 

cause electric shock.

 CAUTION

Install an earth leakage breaker depending on the installa-

tion location of the air conditioner (such as highly humid 

areas).

•  If an earth leakage breaker is not installed, it may cause electric 

shock.

Ensure that the drain water is properly drained.

•  If the drain passage is improper, water may drip down from 

the indoor/outdoor unit, wetting and damaging the furniture.

In case of an abnormal condition

  Immediately stop operating the air conditioner and consult your dealer.

S

AFETY PRECAUTIONS

Do not operate switches with wet hands.

•  This may cause electric shock.

Do not clean the air conditioner with water or place an object 

that contains water, such as a fl ower vase, on it.

•  This may cause fi re or electric shock.

Do not step on or place any object on the outdoor unit.

•  This may cause injury if you or the object falls down.

For installation

SG79F322H03_en.indd   2

2009/06/26   10:54:35

Summary of Contents for MSY-GC25VA

Page 1: ...SPLIT TYPE AIR CONDITIONERS INDOOR UNIT MSY GC25VA MSY GC35VA English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating in structions before use ...

Page 2: ...handling could cause serious hazard depending on the conditions Do not insert your finger a stick or other objects into the air inlet or outlet This may cause injury since the fan inside rotates at high speeds during operation In case of an abnormal condition such as a burning smell stop the air conditioner and disconnect the power plug or turn the breaker OFF A continued operation in the abnormal ...

Page 3: ...hear thunder and there is a possibility of a lightning strike The unit may be damaged if lightning strikes After the air conditioner is used for several seasons per form inspection and maintenance in addition to normal cleaning Dirt or dust in the unit may create an unpleasant odor con tribute to growth of fungi such as mold or clog the drain pas sage and cause water to leak from the indoor unit C...

Page 4: ...lter Air inlet Heat exchanger Front panel Air cleaning filter Anti Allergy Enzyme Filter Fan guard Outdoor unit NAME OF EACH PART PREPARATION BEFORE OPERATION Indoor unit Remote controller Appearance of the outdoor unit may differ from some models R E S E T C L O C K Make sure the polarity of the batteries is correct Do not use manganese batteries The remote controller could malfunction Do not use ...

Page 5: ...mperature About 1 to 2 C from set temperature Lighted Not lighted Emergency operation When the remote controller cannot be used Emergency operation can be activated by pressing the emergency operation switch E O SW on the indoor unit Each time the E O SW is pressed the operation changes in the following order 1 Press to start the operation 2 Press to select operation mode Each press changes mode i...

Page 6: ...ow direction Move the vertical vane manually before starting operation Press during COOL mode page 4 to start ECONO COOL operation The unit performs swing operation vertically in various cycle according to the temperature of the unit Set temperature is set 2 C higher auto matically Press again to cancel ECONO COOL operation Pressing also cancels ECONO COOL operation What is ECONO COOL Swing air flo...

Page 7: ...st performance and to reduce power consumption Moisture in the air conditioner for a long time contributes to growth of fungi such as mold To prevent fungi growth set to the highest temperature in manual COOL mode and operate for 3 or 4 hours to dry out the inside of the unit Air outlet and Fan before cleaning make sure that the fan is stopped Pull to remove from the air filter Air filter Catechin a...

Page 8: ...ints Remote controller The display on the remote controller does not appear or it is dim The indoor unit does not respond to the remote control signal Are the batteries exhausted Page 3 Is the polarity of the batteries correct Page 3 Are any buttons on the remote controller of other electric appliances being pressed Does not cool The room cannot be cooled sufficiently Is the temperature setting app...

Page 9: ...cent lamp Keep a space to prevent the pic ture distortion or the noise 1 m or more Radio 100 mm or more Well ventilated dry place 100 mm or more TV Cordless phone or Portable phone 3 m or more 1 m or more The installation location of the outdoor unit should be at least 3 m away from the antennas for TV sets radios etc In areas where the reception is weak provide greater space between the outdoor u...

Page 10: ......

Page 11: ......

Page 12: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN SG79F322H03 ...

Reviews: