background image

En-5

● OPERATING INSTRUCTIONS ●

F

AN SPEED AND 

AIRFLOW DIRECTION ADJUSTMENT

E

CONO COOL OPERATION 

Press 

 to select fan speed. Each press changes 

fan speed in the following order:

•  Two short beeps are heard from the indoor unit when set to AUTO.

Press 

 to select airfl ow direction. Each press 

changes airfl ow direction in the following order:

•  Two short beeps are heard from the indoor unit when set to AUTO.

•  Press for 2 seconds or more to set to horizontal position. 

•  Press once to cancel horizontal position.

•  When the airflow direction is set to horizontal position, or when hori-

zontal position is cancelled, operation stops for about 3 minutes.

Airflow direction

  (AUTO) .........The vane is set to the most effi cient airfl ow direction. :horizontal 

position. 

 (Manual) .......For efficient air conditioning, select upper position for COOL/

DRY,  and  lower  position  for  FAN.  If  the  lower  position  is 

selected during COOL/DRY, the vane  automatically moves 

to the horizonatal position after 0.5 to 1 hour to prevent any 

condensation from dripping.

 (Swing) .........The vane moves up and down intermittently. 

■ 

To change the horizontal airfl ow direction.

  Move the vertical vane manually before starting operation.

Press 

 during COOL mode 

 page 4 

 to start 

ECONO COOL operation.

The unit performs swing operation vertically in various cycle according 

to the temperature of the unit. Set temperature is set 2°C higher auto-

matically.

Press 

 again to cancel ECONO COOL operation. 

•  Pressing 

 also cancels ECONO COOL operation.

What is “ECONO COOL”?

Swing air fl ow (change of air fl ow) makes you feel cooler than constant air fl ow. 

So, even though the set temperature is automatically set 2°C higher, it is pos-

sible to perform cooling operation with keeping comfort. As a result, energy can 

be saved.

1

Press 

 or 

 during operation to set the timer. 

(ON timer) :   The unit turns ON at the set 

time.

(OFF timer) : The unit turns OFF at the set 

time.

 or 

 blinks.

*  Make sure that the current time is set correctly. 

 

Page 3

 

2

Press 

 (Increase) and 

 (Decrease) to set the 

time of timer. 

Each press increases or decreases the set time by 10 minutes.

• Set the timer while 

 or 

 is blinking.

3

Press

or

again to cancel timer.

Note:

•  ON and OFF timers can be used in combination.   mark indicates the order 

of timer operations.

•  If power failure occurs while ON/OFF timer is set, see 

 page 4 

 “Auto restart 

function”.

  (AUTO)  (Low) 

(Med.) 

(High)  (Super High)

 (AUTO) 

(1) 

 (2) 

(3) 

(4) 

(SWING)

T

IMER OPERATION (ON/OFF TIMER)

SG79F322H03_en.indd   5

2009/06/26   10:54:46

Summary of Contents for MSY-GC25VA

Page 1: ...SPLIT TYPE AIR CONDITIONERS INDOOR UNIT MSY GC25VA MSY GC35VA English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating in structions before use ...

Page 2: ...handling could cause serious hazard depending on the conditions Do not insert your finger a stick or other objects into the air inlet or outlet This may cause injury since the fan inside rotates at high speeds during operation In case of an abnormal condition such as a burning smell stop the air conditioner and disconnect the power plug or turn the breaker OFF A continued operation in the abnormal ...

Page 3: ...hear thunder and there is a possibility of a lightning strike The unit may be damaged if lightning strikes After the air conditioner is used for several seasons per form inspection and maintenance in addition to normal cleaning Dirt or dust in the unit may create an unpleasant odor con tribute to growth of fungi such as mold or clog the drain pas sage and cause water to leak from the indoor unit C...

Page 4: ...lter Air inlet Heat exchanger Front panel Air cleaning filter Anti Allergy Enzyme Filter Fan guard Outdoor unit NAME OF EACH PART PREPARATION BEFORE OPERATION Indoor unit Remote controller Appearance of the outdoor unit may differ from some models R E S E T C L O C K Make sure the polarity of the batteries is correct Do not use manganese batteries The remote controller could malfunction Do not use ...

Page 5: ...mperature About 1 to 2 C from set temperature Lighted Not lighted Emergency operation When the remote controller cannot be used Emergency operation can be activated by pressing the emergency operation switch E O SW on the indoor unit Each time the E O SW is pressed the operation changes in the following order 1 Press to start the operation 2 Press to select operation mode Each press changes mode i...

Page 6: ...ow direction Move the vertical vane manually before starting operation Press during COOL mode page 4 to start ECONO COOL operation The unit performs swing operation vertically in various cycle according to the temperature of the unit Set temperature is set 2 C higher auto matically Press again to cancel ECONO COOL operation Pressing also cancels ECONO COOL operation What is ECONO COOL Swing air flo...

Page 7: ...st performance and to reduce power consumption Moisture in the air conditioner for a long time contributes to growth of fungi such as mold To prevent fungi growth set to the highest temperature in manual COOL mode and operate for 3 or 4 hours to dry out the inside of the unit Air outlet and Fan before cleaning make sure that the fan is stopped Pull to remove from the air filter Air filter Catechin a...

Page 8: ...ints Remote controller The display on the remote controller does not appear or it is dim The indoor unit does not respond to the remote control signal Are the batteries exhausted Page 3 Is the polarity of the batteries correct Page 3 Are any buttons on the remote controller of other electric appliances being pressed Does not cool The room cannot be cooled sufficiently Is the temperature setting app...

Page 9: ...cent lamp Keep a space to prevent the pic ture distortion or the noise 1 m or more Radio 100 mm or more Well ventilated dry place 100 mm or more TV Cordless phone or Portable phone 3 m or more 1 m or more The installation location of the outdoor unit should be at least 3 m away from the antennas for TV sets radios etc In areas where the reception is weak provide greater space between the outdoor u...

Page 10: ......

Page 11: ......

Page 12: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN SG79F322H03 ...

Reviews: