INSTALLATION, RELOCATION AND INSPECTION

CAUTION:

• Earth the unit.

Do  not  connect  the  earth  to  a  gas  pipe,  water  pipe,  lightning  rod  or  the  earth  of  a  telephone.  If  the  earthing  is
incorrect, it may cause an electric shock.

• Install an earth leakage breaker depending on the place where the air conditioner is to be installed (humid places, etc.).

If the earth leakage breaker is not installed, it may cause an electric shock.

Inspection and maintenance

When the air conditioner is used for several seasons, the capacity may be lowered due to dirt inside the unit.

Depending on the condition, an odor may be generated or dehumidified water may not drain out smoothly due to dirt,
dust, etc. This may cause water leakage from the unit.

It is recommended that the unit be inspected and maintained (charged) by specialist in addition to normal maintenance.
Consult your dealer.

Operating sound considerations

Do not put an object around the air outlet of the outdoor unit. This may lower the capacity or increase the volume of the
operating sound.

If an abnormal sound is heard during operation, consult your dealer.

Choose the place which endures the unit weight enought and does not amplify the unit vibration.

Choose the place in which the operation sound and air blow from the unit don

t bother the house next door.

Relocation

When the air conditioner is to be removed or re-installed because of rebuilding, moving, etc., special techniques and
work are required.

 WARNING :

Repairs or relocation should not be done by the customer.
If this is done incorrectly, it may cause a fire, an electric shock, or an injury from the unit falling, water leaking, etc.
Consult your dealer.

Disposal

To dispose of this product, consult your dealer.

If you have any questions, consult your dealer.

SPECIFICATIONS

MSH-GA20VB

MSH-GA25VB

MSH-GA35VB

MSC-GA20VB

MSC-GA25VB

MSC-GA35VB

MUH-GA20VB

MUH-GA25VB

MUH-GA35VB

Cooling

Heating

Cooling

Heating

Cooling

Heating

2.3

2.5

2.65

3.0

3.5

3.7

0.715

0.69

0.82

1.09

1.02

9

10

32

35

0.65

0.80

36/31/25

36/31/25

39/32/25

40/33/26

39/33/26

47

49

Set name

Model

Indoor
Outdoor

Function
Power supply
Capacity

kW

Input

kW

Weight

Indoor

kg

Outdoor

kg

Refrigerant filling

kg

capacity (R410A)

IP code

Indoor
Outdoor

Permissible

LP ps

MPa

excessive
operating

HP ps

MPa

pressure

Indoor

dB(A)

Noise level

(High/Med./Low)
Outdoor

dB(A)

MS-GA20VB

MS-GA25VB

MS-GA35VB

MSC-GA20VB

MSC-GA25VB

MSC-GA35VB

MU-GA20VB

MU-GA25VB

MU-GA35VB

Cooling

2.3

2.5

3.45

0.715

0.775

1.12

9

10

31

30

0.60

0.60

0.70

36/31/25

40/33/26

45

49

~  /N, 230V, 50Hz

IP20
IP24

1.64

4.15

NOTE:

1. Rating condition

Cooling —

Indoor:

27°C DB, 19°C WB

Outdoor:

35°C DB

Heating —

Indoor:

20°C DB

Outdoor:

7°C DB, 6°C WB

2. Guaranteed operating range

Indoor

Outdoor

Upper limit

32

°

C DB

43

°

C DB

Cooling

23

°

C WB

Lower limit

21

°

C DB

21

°

C DB

15

°

C WB

Upper limit

27

°

C DB

24

°

C DB

Heating

18

°

C WB

Lower limit

20

°

C DB

-10

°

C DB

-11

°

C WB

To prevent the effects
of a fluorescent lamp,
keep as far apart as
possible.

wall, etc.

Inverter-type
fluorescent lamp

Keep a space
to prevent the
picture
distortion or
the noise.

1 m

or more

Radio

100 mm or
more

Well-
ventilated
dry place

500 mm or
more

TV

Cordless
phone or
Portable
phone

3 m

or more

1 m

or more

The installation location of the outdoor unit should be
at  least  3  m  away  from  the  antennas  for  TV  sets,
radios, etc. In areas where the reception is weak, pro-
vide greater space between the outdoor unit and the
antenna of the affected device if operation of the air
conditioner interferes with radio or TV reception.

Installation place

Avoid installing the air conditioner in the following places.

Where flammable gas could leak.

CAUTION:

Do not install the unit where flammable gas could leak.
If gas leaks and collects around the unit, it may cause
an explosion.

Where there is much machine oil.

Salty places such as the seaside.

Where sulfide gas is generated such as a hot spring.

Where oil is splashed or where the area is filled with
oily smoke.

Where there is high-frequency or wireless equipment.

Where the unit will be buried in snow.

Inside the mobile vehicles such as a crane truck, ship, etc.

Drain the water from the unit to the soil which has good drainage.

Cooling and heating capacity may get lowered 10%  in the places where poor ventilation and shortcycle of air exchange is likely to occur.

WARNING :

If the air conditioner operates but does not cool or heat (depending on model) the room, consult your dealer since
there may be a refrigerant leak. Be sure to ask the service representative whether there is refrigerant leakage or not
when repairs are carried out.
The refrigerant charged in the air conditioner is safe. Refrigerant normally does not leak, however, if refrigerant gas leaks
indoors, and comes into contact with the fire of a fan heater, space heater, stove, etc., harmful substances will be generated.

Electrical work

Provide an exclusive circuit for the power supply of the air conditioner.

Be sure to observe the breaker capacity.

WARNING :

• The customer should not install this unit.

If installation is done incorrectly, it may cause a fire, an electric shock, or injury from the unit falling, water leaking, etc.

• Do  not  use  intermediate  connection  of  the  power  supply  cord  or  the  extension  cord  and  do  not  connect  many

devices to one AC outlet.
A fire or an electric shock may result from poor contact, poor insulation, exceeding the permissible current, etc.
Consult your dealer.

Summary of Contents for MSC-GA20VB

Page 1: ...men te e p er in tero Ο ΗΓΙΕΣ ΛΕΙΤΟΥΡΓΙΑΣ È ÙÔÓ ÂÏ ÙË È Ó Ú ËÛ ÈÌ Ô ÔÈ Û ÂÙ ٠ÙËÓ Ì ÔÓ Û ˆ Û Ù Î È Ì Â Û Ê ÏÂÈ Â Èˆ ı  Ù fi ÙÈ ÂÙÂ È Û ÂÈ Ùfi ÙÔ ÂÁ ÂÈÚ ÈÔ Ô ËÁ ÈÒ Ó Ú ÈÓ fi ÙËÓ Ú Û Ë INSTRU Ç Õ ES DE OPERAÇ Ã O P a ra os clien tes P a ra utiliz a r esta un id a d e correcta men te certifiq ue se d e q ue lê esta s in struç õ es d e op era ç ã o a n tes d a utiliz a ç ã o B RU G SANV ISNING T il...

Page 2: ... r injury fro m the unit falling w ater leak ing etc C o nsult yo ur d ealer If the p o w er sup p ly co rd is d amag ed it must b e rep laced b y the manufacturer o r its serv ice ag ent in o rd er to av o id a haz ard D o n o t in s e rt y o u r fin g e r o r a s tic k e tc in to th e a ir in le t o u tle t S ince the fan ro tates at hig h sp eed this may cause an injury Y o ung child ren sho ul...

Page 3: ...NS NAME OF EACH PART Indoor unit Outdoor unit Operation Indicator lamp Remote control receiving section Piping Drainage hose Air outlet Drain outlet Air cleaning filter White bellows type OPTION Vertical vane Operation section When the front panel is opened Front panel Air inlet to Breaker Power supply cord Remote control receiving section Display section Air outlet Horizontal vane Remote controll...

Page 4: ... n tro lle r th e o p e ra tio n m o d e th e s e t te m p e ra tu re a n d th e fa n s p e e d a re s to re d in th e m e m o ry If a p o w e r fa ilu re o c c u rs o r th e m a in p o w e r is tu rn e d o ff d u rin g o p e ra tio n A u to re s ta rt fu n c tio n s e ts a u to m a tic a lly to s ta rt o p e ra tin g in th e s a m e m o d e a s th e o n e s e t w ith th e re m o te c o n tro lle ...

Page 5: ...MODE and STOP MODE However when the EMERGENCY OPERATION switch is once pressed the unit will operate in test run for 30 minutes and then the operation mode shifts to EMERGENCY MODE Details of EMERGENCY MODE are as shown below However the temperature control does not work for 30 minutes in test run and the unit is set to continuous operation The fan speed is set to High in test run and shifts to Me...

Page 6: ...CK Details of operation According to the room temperature when the operation starts the operation mode is automatically set to COOL DRY or HEAT However when operation is started again within 2 hours after it is stopped the same operation mode before the operation is stopped is selected The operation mode selected first is not changed even if the room temperature changes If the operation mode does ...

Page 7: ... the operation while the defrosting of outdoor unit is being done it takes a few minutes max 10 minutes to blow out the warm air In the heating operation the indoor unit that does not operate may get warm or the sound of refrigerant flowing may be heard This is not a malfunction since the refrigerant continuously flows into the indoor unit that does not operate Description of AUTO RESTART FUNCTION...

Page 8: ...rs while AUTO START STOP timer is active the timer setting is cancelled As these models are equipped with an auto restart function the air conditioner starts operating with timer cancelled at the same time that power is restored What is ECONO COOL Swing air flow change of air flow makes you feel cooler than constant air flow So even though the set temperature is automatically set 2 C higher it is ...

Page 9: ...ilter is dyed with a natural material catechin that is contained in tea The catechin air filter deodorizes odor and noxious gases such as formaldehyde ammonia and acetaldehyde Moreover it restraints the activity of the viruses adhering to the filter Air cleaning filter Remove the catechin air filter Remove the air cleaning filter White bellows type Install a new air cleaning filter Install the cat...

Page 10: ... FUNCTION on page 6 Q uestion The air flow direction changes during operation The direction of the hori zontal vane cannot be ad justed with the remote con troller Water leaks from the out door unit White smoke is discharged from the outdoor unit Air does not blow out soon in the heating operation The operation is stopped for about 10 minutes in the heating operation Hissing sound is some times he...

Page 11: ... C DB 19 C WB Outdoor 35 C DB Heating Indoor 20 C DB Outdoor 7 C DB 6 C WB 2 Guaranteed operating range Indoor Outdoor Upper limit 32 C DB 43 C DB Cooling 23 C WB Lower limit 21 C DB 21 C DB 15 C WB Upper limit 27 C DB 24 C DB Heating 18 C WB Lower limit 20 C DB 10 C DB 11 C WB To prevent the effects of a fluorescent lamp keep as far apart as possible wall etc Inverter type fluorescent lamp Keep a...

Page 12: ...in c u i s i v e rific h i u n p ro b le m a o u n a n o m a lia S im b o li p re c a u z io n a li e d i lo ro s ig n ific a ti A V V E R T E N Z A L u s o s c o rre tto p u ò fa c ilm e n te c a u s a re le s io n i g ra v i o m o rte C A U T E L A L u s o s c o rre tto p u ò c a u s a re le s io n i g ra v i in d e te rm in a te c irc o s ta n z e S ig n ific a ti d e i s im b o li u s a ti in ...

Page 13: ...NORME DI SICUREZZA CAUTELA Per l installazione AVVERTENZA Per l installazione consultare il proprio rivenditore o contraente Trattandosi di operazioni particolarmente tecniche I installazione non deve essere effettuata dal cliente Se l installazione non viene effettuata correttamente potrebbe causare incendio shock elettrico danni o fuoriuscita di acqua Non installare il climatizzatore in luoghi d...

Page 14: ... v e lo c ità d e lla v e n to la s o n o m a n te n u ti in m e m o ria S e s i v e rific a u n in te rru z io n e d i c o rre n te o s e s i s p e g n e l a lim e n ta z io n e p rin c ip a le d u ra n te il fu n z io n a m e n to q u e s ta fu n z io n e ria v v ia a u to m a tic a m e n te l a p p a re c c h io c o m e e ra s ta to im p o s ta to c o n il te le c o m a n d o im m e d ia ta m e...

Page 15: ...ti e quindi passerà in MODO EMERGENZA La seguente tabella mostra i dettagli del MODO EMERGENZA Tuttavia il controllo della tempera tura non funziona per i primi 30 minuti in modo funzionamento di prova e l unità è impostata nel modo di funzionamento continuo La velocità della ventola è impostata su Alta du rante il funzionamento di prova e passa su Media dopo 30 minuti Modo funzionamento Raffredda...

Page 16: ...ONE RISCALDAMEN TO VENTILAZIONE Tipo RAFFREDDAMENTO e RISCALDAMENTO Tipo SOLO RAFFREDDAMENTO Temperatura Modo di Temperatura obiettivo Modo di Temperatura obiettivo ambiente iniziale funzionamento condizione iniziale funzionamento condizione iniziale Circa 25 C o più RAFFREDDAMENTO Circa 24 C RAFFREDDAMENTO Circa 24 C Circa 25 C 23 C DEU MIDIFICAZIONE DEU MIDIFICAZIONE Circa 23 C o meno RISCALDAME...

Page 17: ...amento a pagina 56 In questo caso si prega di impostare tutte le unità interne nella stessa modalità di funzionamento Quando la unità interna inizia a funzionare una volta completata la fase di sbrinamento della unità esterna ci vorranno alcuni minuti max 10 minuti prima che venga soffiata aria calda Nella modalità di riscaldamento la unità interna che non sta funzionando può riscaldarsi oppure si...

Page 18: ...are che il filo di messa a terra sia collegato correttamente CAUTELA Mettere a terra il climatizzatore Non collegare il filo di messa a terra con una tubazione dell acqua del gas un parafulmine o un filo del telefono Se la messa a terra non è buona si possono verificare folgorazioni MANUTENZIONE Prima di iniziare la manutenzione Disattivare l interruttore di circuito e o scolle gare la spina d ali...

Page 19: ...con un materiale naturale contenuto nel tè la catechina Il filtro dell aria alla catechina deodora e combatte i gas nocivi quali la formaldeide l ammoniaca e l acetaldeide Inoltre limita l attività dei virus che aderiscono al filtro PULIZIA DEL FILTRO DELL ARIA ALLA CATECH INA Pulizia del filtro dell aria alla catechina circa ogni 2 settimane SOSTITUZIONE DEL FILTRO DI PULIZIA DELL ARIA OPZIONE Qu...

Page 20: ...o scambiatore di calore Questo è il rumore del refrigerante che scorre nel climatizzatore Questo è il rumore dell acqua che si condensa all interno della pompa di calore Questo é il rumore prodotto dallo sbrinamento della pompa d aria Questo suono viene avvertito quando l aria esterna viene assorbita dal tubo di scarico ruotando la cappa o il sistema di ventilazione e che fa in modo che l acqua ch...

Page 21: ...lo Interno Esterno Funzioni Alimentazione Capacità k W Ingresso k W Peso Interno k g Esterno k g Capacità fluido k g refrigerante R410A Codice IP Interno Esterno Lato MPa aspirazione Lato MPa scarico Interno dB A Alto Medio Basso Esterno dB A MS GA20VB MS GA25VB MS GA35VB MSC GA20VB MSC GA25VB MSC GA35VB MU GA20VB MU GA25VB MU GA35VB Raffreddamento 2 3 2 5 3 45 0 715 0 775 1 12 9 10 31 30 0 60 0 6...

Reviews: