En-8

W

HEN YOU THINK THAT TROUBLE HAS OCCURRED

Even if these items are checked, when the unit does not recover from the 

trouble, stop using the air conditioner and consult your dealer.

Symptom

Explanation & Check points

Indoor Unit

The unit cannot be operated.

•  Is the breaker turned on?

•  Is the power supply plug connected?

•  Is the ON timer set? 

 Page 6 

The unit cannot be operated 

for about 3 minutes when 

restarted.

•  This protects the unit according to instruc-

tions  from  the  microprocessor.  Please 

wait.

The fan stops during the DRY 

operation.

•  In DRY operation, the unit operates using the 

same refrigerant circuit as in COOL opera-

tion. DRY operation time has to be reduced 

in order to lower humidity without much room 

temperature  decreasing.  So  the  compres-

sor sometimes stops, and at the same time 

the  indoor  fan  stops.  This  prevents  water 

condensed  on  the  heat  exchanger  from 

evaporating again.

Mist is discharged from the air 

outlet of the indoor unit.

•  The cool air from the unit rapidly cools mois-

ture in the air inside the room, and it turns 

into mist.

The swing operation of the 

HORIZONTAL VANE is 

suspended for a while, then 

restarted.

•  This is for the swing operation of the HORI-

ZONTAL VANE to be performed normally.

The air fl ow direction changes 

during operation.

The direction of the horizontal 

vane cannot be adjusted with 

the remote controller.

•  When the unit is operated in COOL or DRY 

mode,  if  the  operation  continues  with  air 

blowing down for 0.5 to 1 hour, the direction 

of the air fl ow is automatically set to horizon-

tal position to prevent water from condensing 

and dripping.

•  In  the  heating  operation,  if  the  air  flow 

temperature is too low or when defrosting is 

being done, the horizontal vane is automati-

cally set to horizontal position.

The operation is stopped for 

about 10 minutes in the heat-

ing operation.

•  Defrosting  of  the  outdoor  unit  is  being 

done.

  Since this is completed in max.10 minutes, 

please wait. (When the outside temperature 

is too low and humidity is too high, frost is 

formed.)

The unit starts operation by 

itself when the main power 

is turned on, though it isn’t 

operated with the remote 

controller.

•  These models are equipped with an auto re-

start function. When the main power is turned 

off without stopping the unit with the remote 

controller  and  is  turned  on  again,  the  unit 

starts operation automatically in the same 

mode as the one set with the remote control-

ler just before the shutoff of the main power. 

Refer to “Auto restart function” 

 Page 4 

.

The indoor unit discolors over 

time.

•  Although plastic turns yellow due to the infl u-

ence of some factors such as ultraviolet light 

and temperature, this has no effect on the 

product functions.

Outdoor Unit

Water leaks from the outdoor 

unit.

•  During COOL and DRY operations, pipe or 

pipe connecting sections are cooled and this 

causes water to condense.

•  In the heating operation, water condensed 

on the heat exchanger drips down.

•  In the heating operation, the defrosting op-

eration makes water frozen on the outdoor 

unit melt and drip down.

White smoke is discharged 

from the outdoor unit.

•  In  the  heating  operation,  vapor  generated 

by the defrosting operation looks like white 

smoke.

In the following cases, stop using the air conditioner and consult your 

dealer.

•  When water leaks or drips from the indoor unit.

•  When the upper operation indicator lamp blinks.

•  When the breaker trips frequently.

•  The remote control signal is not received in a room where an electronic ON/OFF 

type fl uorescent lamp (inverter-type fl uorescent lamp, etc.) is used.

•  Operation of the air conditioner interferes with radio or TV reception. An ampli-

fi er may be required for the affected device.

•  When an abnormal sound is heard.

Symptom

Explanation & Check points

Remote controller

The display on the remote 

controller does not appear or 

it is dim. The indoor unit does 

not respond to the remote 

control signal.

•  Are the batteries exhausted? 

 Page 3 

•  Is the polarity (+, -) of the batteries correct?

 Page 3 

•  Are any buttons on the remote controller of 

other electric appliances being pressed?

Does not cool or heat

The room cannot be cooled or 

heated suffi ciently.

•  Is the temperature setting appropriate? 

 

 Page 4 

•  Is the fan setting appropriate? Please change 

fan speed to higher setting. 

 Page 5 

•  Are the fi lters clean? 

 Page 7 

•  Is the fan or heat exchanger of the indoor unit 

clean? 

•  Are there any obstacles blocking the air inlet or 

outlet of the indoor or outdoor unit?

•  Is a window or door open?

The room cannot be cooled 

suffi ciently.

•  When a ventilation fan or a gas cooker is used 

in a room, the cooling load increases, resulting 

in an insuffi cient cooling effect.

•  When the outside temperature is high, the cool-

ing effect may not be suffi cient.

The room cannot be heated 

suffi ciently.

•  When the outside temperature is low, the heat-

ing effect may not be suffi cient.

Air does not blow out soon in 

the heating operation.

•  Please wait as the unit is preparing to blow 

out warm air.

Airfl ow

The air from the indoor unit 

smells strange.

•  Is the fi lter clean? 

 Page 7 

•  Is the fan or heat exchanger of the indoor 

unit clean?

•  The unit may suck in an odor adhering to the 

wall, carpet, furniture, cloth, etc. and blow it 

out with the air.

Sound

Cracking sound is heard.

•  This sound is generated by the expansion/

contraction  of  the  front  panel,  etc.  due  to 

change in temperature.

“Burbling” sound is heard.

•  This sound is heard when the outside air is 

absorbed from the drain hose by turning on 

the range hood or the ventilation fan, mak-

ing water fl owing in the drain hose to spout 

out.

  This sound is also heard when the outside air 

blows into the drain hose in case the outside 

wind is strong.

Mechanical sound is heard

from the indoor unit.

•  This is the switching sound in turning on/off 

the fan or the compressor.

The sound of water fl owing 

is heard.

•  This is the sound of refrigerant or condensed 

water fl owing in the unit.

SG79F752H01_en.indd   8

2013/07/10   11:40:33

Summary of Contents for MS-GH80VA

Page 1: ...IT TYPE AIR CONDITIONERS MSH GF50VA MSH GF60VA MSH GF80VA INDOOR UNIT English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating in structions before use ...

Page 2: ...onditioner may cause fire electric shock injury or water leakage etc Consult your dealer If the power supply cord is damaged it must be replaced by the manufacturer or its service agent in order to avoid a hazard When installing relocating or servicing the unit make sure that no substance other than the specified refrigerant R410A enters the refrigerant circuit Any presence of foreign substance such...

Page 3: ...ter and immediately seek medical atten tion Ensure that the area is well ventilated when the unit is operated together with a combustion appliance Inadequate ventilation may cause oxygen starvation Turn the breaker OFF when you hear thunder and there is a pos sibility of a lightning strike The unit may be damaged if lightning strikes After the air conditioner is used for several seasons perform in...

Page 4: ...e 3 RESET button Page 3 Lid Slide down to open Install the remote control ler holder in a place where the signal can be received by the indoor unit Only use the remote controller provided with the unit Do not use other remote controllers If two or more indoor units are installed in proximity to one another an indoor unit that is not intended to be operated may respond to the remote controller Inst...

Page 5: ... timer is set timer setting is cancelled and the unit starts operation when power is resumed If you do not want to use this function please consult the service repre sentative because the setting of the unit needs to be changed SELECTING OPERATION MODES Set temperature 24 C Fan speed Medium Horizontal vane Auto I FEEL COOL DRY HEAT Note The first 30 minutes of operation is test run Temperature cont...

Page 6: ...rizontal position after 0 5 to 1 hour to prevent any condensation from dripping Swing The vane moves up and down intermittently AUTO Low Med High Super High AUTO 1 2 3 4 5 SWING SWING OPERATING INSTRUCTIONS FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT LONG OPERATION Press to start LONG operation Fan speed increases and the horizontal vane moves to the position for LONG mode Air reaches to longer dis...

Page 7: ...cally set at 2 C higher it is possible to perform cooling operation with keeping comfort As a result energy can be saved TIMER OPERATION ON OFF TIMER 1 Press or during operation to set the timer ON timer The unit turns ON at the set time OFF timer The unit turns OFF at the set time or blinks Make sure that the current time is set correctly Page 3 2 Press Increase and Decrease to set the time of ti...

Page 8: ... also to eliminate bacteria and viruses This air filter has a semi permanent lasting effect even after washing it with water Air cleaning filter Electrostatic anti allergy enzyme filter option Every 3 months Remove dirt by a vacuum cleaner When dirt cannot be removed by vacuum cleaning Soak the filter and its frame in lukewarm water before rinsing it After washing dry it well in shade Every year Repla...

Page 9: ...his causes water to condense In the heating operation water condensed on the heat exchanger drips down In the heating operation the defrosting op eration makes water frozen on the outdoor unit melt and drip down White smoke is discharged from the outdoor unit In the heating operation vapor generated by the defrosting operation looks like white smoke In the following cases stop using the air condit...

Page 10: ...ortable phone 3 m or more 1 m or more The installation location of the outdoor unit should be at least 3 m away from the antennas for TV sets radios etc In areas where the reception is weak provide greater space between the outdoor unit and the antenna of the affected device if operation of the air conditioner interferes with radio or TV reception 1 Set to the highest temperature in manual COOL mo...

Reviews: