background image

En-7

● OPERATING INSTRUCTIONS ●

C

LEANING

Instructions:

 

•  Switch off the power supply or turn off the breaker before cleaning.

•  Be careful not to touch the metal parts with your hands.

•  Do not use benzine, thinner, polishing powder, or insecticide.

•  Use only diluted mild detergents.

•  Do not expose parts to direct sunlight, heat, or fi re to dry.

•  Do not use water hotter than 50°C.

Hole

Hinge

Air fi lter (Nano platinum fi lter)

• 

 

Clean every 2 weeks

 

•  Remove dirt by a vacuum cleaner, or rinse with water.

•  After washing with water, dry it well in shade.

What is “Nano platinum fi lter”?

Nano platinum is a ceramic particle that includes a platinum nanoparticle. 

The particles are incorporated into the fi lter material, which results in pro-

viding semi-permanent antibacterial and deodorizing characteristics for the 

fi lter. Nano platinum surpasses the catechin (a biofl avonoid that is found 
in green tea) in performance. Nano platinum fi lter uses this compound not 

only to improve air quality but also to eliminate bacteria and viruses. This air 

fi lter has a semi-permanent lasting effect even after washing it with water.

Air cleaning fi lter 

(Electrostatic anti-allergy enzyme fi lter, 

option)

Every 3 months:

•  Remove dirt by a vacuum cleaner.

When dirt cannot be removed by vacuum cleaning:

• 

Soak the fi lter and its frame in lukewarm water before rinsing it.

•  After washing, dry it well in shade.

Every year:

•  Replace it with a new air cleaning fi lter for best performance.

•  Parts Number 

 MAC-2310FT-E 

 

 Important

• 

Clean the fi lters regularly for best performance and to 

reduce power consumption.

• 

Dirty  fi lters  cause  condensation  in  the  air  conditioner 

which  will  contribute  to  the  growth  of  fungi  such  as 

mold.  It  is  therefore  recommended  to  clean  air  fi lters 

every 2 weeks.

1. Lift the front panel until a “click” is heard.
2. Hold the hinges and pull to remove as shown in the left illustration.

•  Wipe with a soft dry cloth or rinse it with water.

•  Do not soak it in water for more than two hours.

•  Dry it well in shade.

3. Install  the  front  panel  by  following  the  removal  procedure  in  reverse. 

Close the front panel securely and press the positions indicated by the 

arrows.

Front panel

SG79F752H01_en.indd   7

2013/07/10   11:40:32

Summary of Contents for MS-GH80VA

Page 1: ...IT TYPE AIR CONDITIONERS MSH GF50VA MSH GF60VA MSH GF80VA INDOOR UNIT English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating in structions before use ...

Page 2: ...onditioner may cause fire electric shock injury or water leakage etc Consult your dealer If the power supply cord is damaged it must be replaced by the manufacturer or its service agent in order to avoid a hazard When installing relocating or servicing the unit make sure that no substance other than the specified refrigerant R410A enters the refrigerant circuit Any presence of foreign substance such...

Page 3: ...ter and immediately seek medical atten tion Ensure that the area is well ventilated when the unit is operated together with a combustion appliance Inadequate ventilation may cause oxygen starvation Turn the breaker OFF when you hear thunder and there is a pos sibility of a lightning strike The unit may be damaged if lightning strikes After the air conditioner is used for several seasons perform in...

Page 4: ...e 3 RESET button Page 3 Lid Slide down to open Install the remote control ler holder in a place where the signal can be received by the indoor unit Only use the remote controller provided with the unit Do not use other remote controllers If two or more indoor units are installed in proximity to one another an indoor unit that is not intended to be operated may respond to the remote controller Inst...

Page 5: ... timer is set timer setting is cancelled and the unit starts operation when power is resumed If you do not want to use this function please consult the service repre sentative because the setting of the unit needs to be changed SELECTING OPERATION MODES Set temperature 24 C Fan speed Medium Horizontal vane Auto I FEEL COOL DRY HEAT Note The first 30 minutes of operation is test run Temperature cont...

Page 6: ...rizontal position after 0 5 to 1 hour to prevent any condensation from dripping Swing The vane moves up and down intermittently AUTO Low Med High Super High AUTO 1 2 3 4 5 SWING SWING OPERATING INSTRUCTIONS FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT LONG OPERATION Press to start LONG operation Fan speed increases and the horizontal vane moves to the position for LONG mode Air reaches to longer dis...

Page 7: ...cally set at 2 C higher it is possible to perform cooling operation with keeping comfort As a result energy can be saved TIMER OPERATION ON OFF TIMER 1 Press or during operation to set the timer ON timer The unit turns ON at the set time OFF timer The unit turns OFF at the set time or blinks Make sure that the current time is set correctly Page 3 2 Press Increase and Decrease to set the time of ti...

Page 8: ... also to eliminate bacteria and viruses This air filter has a semi permanent lasting effect even after washing it with water Air cleaning filter Electrostatic anti allergy enzyme filter option Every 3 months Remove dirt by a vacuum cleaner When dirt cannot be removed by vacuum cleaning Soak the filter and its frame in lukewarm water before rinsing it After washing dry it well in shade Every year Repla...

Page 9: ...his causes water to condense In the heating operation water condensed on the heat exchanger drips down In the heating operation the defrosting op eration makes water frozen on the outdoor unit melt and drip down White smoke is discharged from the outdoor unit In the heating operation vapor generated by the defrosting operation looks like white smoke In the following cases stop using the air condit...

Page 10: ...ortable phone 3 m or more 1 m or more The installation location of the outdoor unit should be at least 3 m away from the antennas for TV sets radios etc In areas where the reception is weak provide greater space between the outdoor unit and the antenna of the affected device if operation of the air conditioner interferes with radio or TV reception 1 Set to the highest temperature in manual COOL mo...