MXZ-2B52/3B/4B71/3C/4C71VA
33
76
98 120 142 163 185 207
55
MXZ-2B30/2B40VA
MXZ-4B80/5B100/4C80/5C100VA
23
20
40
49
59
69
79
89
99
MXZ-6C120VA
30
Compressor operating frequency (Hz)
4Hz
01
02
03
04
05
06
07
08
09
10
LEV Opening (code)
MXZ-2B30VA
Standard opening (pulse)
LEV Opening(code)
1
2
3
4
5
6
7
8
9
10
COOL
340 360 360 360 390 390 390 390 400 410
HEAT
200 220 250 280 300 320 340 360 380 400
MXZ-2B40VA
Standard opening (pulse)
LEV Opening(code)
1
2
3
4
5
6
7
8
9
10
COOL
240 260 280 300 330 350 370 390 400 410
HEAT
200 220 250 280 300 320 340 360 380 400
MXZ-2B52VA
Standard opening (pulse)
LEV Opening(code)
1
2
3
4
5
6
7
8
9
10
COOL
340 360 360 360 390 390 390 390 400 410
HEAT
200 220 250 280 300 320 340 360 380 400
Operation number
Difference in capacity
Difference in operation number
Code3,4 Code5,6 Code7,8
2
COOL 10
20
30
-60
HEAT 5
10
15
-100
• The standard opening is on the straight line, which connects an each standard point in the section where divided into seven
according to the operation frequency of compressor as shown in the figure below.
(LEV opening is controlled in proportion to the operation frequency.)
NOTE
: Opening is adjusted at the standard opening according to the indoor unit conditions.
However, inclination of standard opening in each point of opening does not change with the original curve.
• Add opening provided in Difference in Capacity in the table below to the standard opening from 1 to 8 (
MXZ-2B
)/ 1 to 15 or
above (
MXZ-3B/4B/5B/3C/4C/5C/6C
), when capacity of the indoor unit is excluding code 1.
• Add opening provided in Difference in Operation number in the table below to determined LEV opening for each indoor unit,
when 2, 3, 4, 5 or 6 indoor units are operated at the same time.
NOTE:
Even when the adjusted standard opening exceeds the driving range from 59 to 500 pulse, actual driving output opening
is in a range from 59 to 500 pulse.