4
2. COMPRESSOR TECHNICAL DATA
Compressor
RH247VFC
NHJ33NBD
NHJ41VMD
NHJ38NBD
NHJ41VMD
NHJ52VND
NHJ52YDE
NHJ47NAD
NH56VND
NHJ56YDE
NHJ56TKA
Winding resistance(
"
).
at 20
:
R-C/U-V
S-C/V-W
W-U
2.00
4.55
–
0.70
1.44
–
0.92
2.44
–
0.70
1.42
–
0.92
2.44
–
0.83
2.03
–
3.68
3.68
–
0.58
1.14
3.68
0.64
1.55
–
3.30
3.30
3.30
0.83
0.83
0.83
Outdoor unit
Service Ref.
PU-1.6VLJA
2
.UK
PU-2NJA
1
.UK
PU-2VJA
2
.UK
PU-2.5NJA
1
.UK
PU-2.5VJA
2
.UK
PU-3VJA
2
.UK
PU-3YJA
2
.UK
PU-3NJA
1
.UK
PU-4VLJSA
2
.UK
PU-4YJSA
2
.UK
PU-4TJSA
1
.UK
Compressor
Winding resistance(
"
).
at 25
:
T
1
–T
2
T
2
–T
3
T
3
–T
1
Outdoor unit
Service Ref.
ZR61KC-TFD
2.53–2.91
2.53–2.91
2.53–2.91
PU-5YJSA.UK
ZR61KC-TF5
0.628–0.722
0.628–0.722
0.628–0.722
PU-5TJSA.UK
ZR72KC-TFD
2.148–2.472
2.148–2.472
2.148–2.472
PU-6YJSA.UK
ZR68KC-TF5
0.517
0.517
0.517
PU-6TJSA.UK
3. ADDITIONAL REFRIGERANT CHARGE (R-22……kg (lbs))
Service Ref.
Outdoor unit
precharged (kg)
(up to 20m)
Refrigerant piping length (one way)
PU-1.6VLJA
2
.UK
PU-2VJA
2
.UK
PU-2NJA
1
.UK
PU-2.5VJA
2
.UK
PU-2.5NJA
1
.UK
PU-3VJA
2
.UK
PU-3YJA
2
.UK
PU-3NJA
1
.UK
PU-4VLJSA
2
.UK
PU-4YJSA
2
.UK
PU-4TJSA
1
.UK
1.3
1.78
1.9
2.4
2.4
3.08
2.88
3.5
3.8
4.6
4.6
20m (66ft)
25m (82ft)
30m (98ft) 35m (115ft) 40m (131ft)
0
0
0
0
0
0
0
0
0
0
0
–
0.06 (0.13)
0.06 (0.13)
0.06 (0.13)
0.06 (0.13)
0.06 (0.13)
0.06 (0.13)
0.06 (0.13)
0.15 (0.33)
0.15 (0.33)
0.15 (0.33)
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
0.45 (0.99)
0.6 (1.32)
0.45 (0.99)
0.6 (1.32)
0.45 (0.99)
0.6 (1.32)
45m (148ft)
–
–
–
–
–
–
–
–
–
–
–
50m (164ft)
–
–
–
–
–
–
–
–
–
–
–
0.12 (0.26)
0.12 (0.26)
0.12 (0.26)
0.12 (0.26)
0.12 (0.26)
0.12 (0.26)
0.12 (0.26)
0.30 (0.66)
0.30 (0.66)
0.30 (0.66)
PU-5YJSA.UK
5.1
0
0.15 (0.33)
0.45 (0.99)
0.6 (1.32)
0.75 (1.65)
0.9 (1.98)
0.30 (0.66)
PU-5TJSA.UK
5.1
0
0.15 (0.33)
0.45 (0.99)
0.6 (1.32)
0.75 (1.65)
0.9 (1.98)
0.30 (0.66)
PU-6YJSA.UK
5.7
0
0.15 (0.33)
0.45 (0.99)
0.6 (1.32)
0.75 (1.65)
0.9 (1.98)
0.30 (0.66)
PU-6TJSA.UK
5.7
0
0.15 (0.33)
0.45 (0.99)
0.6 (1.32)
0.75 (1.65)
0.9 (1.98)
0.30 (0.66)