32
7-6. HOW TO CHECK THE PARTS
PE-3EAK.TH
PE-4EAK.TH
PE-5EAK.TH
PE-6EAK.TH
PE-3EAK.TH-U
PE-4EAK.TH-U
PE-5EAK.TH-U
PE-6EAK.TH-U
Room temperature
thermistor
(TH1)
Indoor coil thermistor
(TH2)
Fan motor
Disconnect the connector, then measure the resistance using a tester.
(Surrounding temperature 10°C~30°C)
Measure the resistance between the terminals using a tester.
(Surrounding temperature 20°C)
(Refer to the thermistor)
Normal
4.3k
'
~9.6k
'
Abnormal
Open or short
Motor terminal
or
Relay connector
Normal
PE-EAK.TH(-U)
3
Abnormal
WHT-BLK
46.38
'
Open or short
17.25
'
BLU
YL
W
RED
ORN
Capacitor
WHT
BLK
BLU
Protector
1
2
3
4
5
6
7
1
3
5
Parts name
Check points
5, 6
0
10
20
30
40
50
-20
-10
0
10
20
30
40
50
< Thermistor for lower temperature >
Temperature (
:
)
Resistance (K
"
)
<Thermistor Characteristic graph>
Room temperature thermistor(TH1)
Indoor coil thermistor(TH2)
Thermistor R
0
=15k
'
± 3%
Fixed number of B=3480 ± 2%
Rt=15exp { 3480( ) }
0
:
15k
'
10
:
9.6k
'
20
:
6.3k
'
25
:
5.2k
'
30
:
4.3k
'
40
:
3.0k
'
Thermistor for
lower temperature
1
273+t
1
273
4
BLK-BLU
BLU-YLW
YLW-RED
18.37
'
(BLU-RED)
20.63
'
8.05
'
3.18
'
15.26
'
5.118
'
16.02
'
2.648
'
14.49
'