23
9-2. MU-A24ND
OUTDOOR UNIT
OPERATING PROCEDURE
PHOTOS
1.Removing the cabinet
(1) Remove the screw of the service panel.
(2) Remove the screws of the top panel.
(3) Remove the screw of the valve cover.
(4) Remove the service panel.
(5) Remove the top panel.
(6) Remove the valve cover.
(7) Remove the screws of the front panel.
(8) Remove the front panel.
(9) Remove the screws of the back panel.
(10) Remove the back panel.
Photo 2
Photo 1
Photo 3
Screw of the top panel
Screws of the cabinet
Screws
of the
cabinet
Screws
of the
top
panel
Screw of the motor support
Set screws of the back panel
Screws
of the
front
panel
2. Removing the electrical parts
(1) Remove the service panel and the cabinet.
(2) Remove the following parts.
•Compressor capacitor (C1)
•Outdoor fan capacitor (C2)
•Terminal blocks (TB1,TB2)
•Compressor contactor (52C)
(MU-A24ND-
)
S2
Screw of the service panel
Screw
of the
valve
cover
Screws
of the
back
panel
Photo 4
Screws
of the
relay
panel
Compressor
capacitor (C1)
Outdoor fan
capacitor (C2)
Terminal
blocks
(TB1,TB2)
Screws
of the
relay
panel
Screws of the relay panel
Photo : MU-A24ND -
S2
Compressor
contactor
(MU-A24
ND-
)
S2
OB405E.qxp 09.10.14 9:16 AM Page 23