22
OPERATING PROCEDURE
PHOTOS
2. Removing the electrical parts
(1) Remove the service panel and the cabinet.
(2) Remove the following parts.
•Compressor capacitor (C1)
•Outdoor fan capacitor (C2)
•Terminal blocks (TB1,TB2)
Photo 3
Compressor capacitor(C1)
3. Removing the outdoor fan motor
(1) Remove the cabinet. (Refer to 1.)
(2) Disconnect the connector remove the hooked lead wire
from the fan motor.
(3) Remove the propeller nut and remove the propeller.
(4) Remove screws fixing the fan motor.
4. Removing the compressor
(1) Remove the cabinet. (Refer to 1.)
(2) Remove the soundproof felt.
(3) Remove the terminal cover on the compressor.
(4) Disconnect lead wires from the glass terminal of the com-
pressor.
(5) Recover gas from the refrigerant circuit.
NOTE:
Recover gas from the pipes until the pressure gauge
shows 0 kg/cm
2
(0MPa).
(6) Disconnect the welded part of the discharge pipe.
(7) Disconnect the welded part of the suction pipe.
(8) Remove nuts fixing the compressor.
(9) Remove the compressor.
Photo 4
Hook
Propeller
Propeller
nut
Outdoor fan capacitor(C2)
Terminal
blocks(TB1,TB2)
Set screws of
Outdoor fan motor
Set screws of
outdoor fan motor
Photo 5
Compressor
Discharge
pipe
Suction
pipe
Compressor nuts
OB405E.qxp 09.10.14 9:16 AM Page 22