background image

En-5

• OPERATING INSTRUCTIONS •

F

AN SPEED AND 

AIRFLOW DIRECTION ADJUSTMENT

Press 

 to select fan speed. Each press changes 

fan speed in the following order:

• Two short beeps are heard from the indoor unit when set to AUTO.
• Use higher fan speed to cool/heat the room quicker. It is recommended 

to lower the fan speed once the room is cool/warm.

• Use lower fan speed for quiet operation.

Note:

Multi system operation

When several indoor units are operated simultaneously by one outdoor unit for 
heating operation, the temperature of the air

fl

 ow may be low. In this case, it is 

recommended to set the fan speed to AUTO.

Press 

 to select air

fl

 ow direction. Each press 

changes air

fl

 ow direction in the following order:

•  Two short beeps are heard from the indoor unit when set to AUTO.

Press 

 to select horizontal air

fl

 ow direction. Each 

press changes air

fl

 ow direction in the following order:

Airflow direction

  (AUTO) .........The vane is set to the most ef

fi

 cient air

fl

 ow direction. COOL/

DRY:horizontal position. HEAT:position (5).

 (Manual) .......For efficient air conditioning, select the upper position for 

COOL/DRY, and the lower position for HEAT. If the lower 
position is selected during COOL/DRY, the vane automatically 
moves to the horizontal position after 0.5 to 1 hour to prevent 
any condensation from dripping.

  (Swing) .........The vane moves up and down intermittently.

  (AUTO)  (Quiet) 

(Low) 

(Med.) 

(High)  (Super High)

 (AUTO) 

(1) 

 (2) 

(3) 

(4) 

(5) 

(SWING)

L

ONG OPERATION

Press 

 to start LONG operation.

• Fan speed increases and the horizontal vane moves to the position 

for LONG mode.

• Air reaches to longer distance.

Press 

 again to cancel LONG operation.

• LONG operation is cancelled when the ON/OFF, VANE, or ECONO 

COOL button is pressed.

Press 

 during COOL or HEAT mode 

 Page 4 

 to 

start POWERFUL operation.

Fan speed 

:  Exclusive speed for POWERFUL mode 

Horizontal vane  : Set position, or downward airflow position during 

AUTO setting

•  Temperature cannot be set during POWERFUL operation.

Press 

 again to cancel POWERFUL operation. 

• POWERFUL operation also is cancelled automatically in 15 min-

utes, or when the ON/OFF, FAN, ECONO COOL, or i-save button is 
pressed.

P

OWERFUL OPERATION

(SWING)

Summary of Contents for Mr.Slim MSZ-SGH24VA

Page 1: ...SPLIT TYPE AIR CONDITIONERS INDOOR UNIT MSZ SGH24VA English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating in structions before use ...

Page 2: ...t handling could cause serious hazard depending on the conditions This appliance is not intended for use by persons including children with reduced physical sensory or mental capabili ties or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that th...

Page 3: ...attery fluid comes in contact with your eyes wash them thoroughly with clean water and immediately seek medical attention Ensure that the area is well ventilated when the unit is oper ated together with a combustion appliance Inadequate ventilation may cause oxygen starvation Turn the breaker OFF when you hear thunder and there is a possibility of a lightning strike The unit may be damaged if ligh...

Page 4: ...s when pressed longer Indoor unit Remote controller Outdoor units may be different in appearance 1 Remove the front lid 2 Insert AAA alkaline batteries 3 Install the front lid 4 Press RESET Air cleaning filter Electrostatic anti al lergy enzyme filter Signal transmitting section Distance of signal About 6 m Beep s is are heard from the indoor unit when the signal is received Operation display sect...

Page 5: ...Press or to set the temperature Each press raises or lowers the temperature by 1 C Press to stop the operation The same setting is selected the next time by simply pressing Auto restart function If a power failure occurs or the main power is turned off during operation Auto restart function automatically starts operation in the same mode as the one set with the remote controller just before the sh...

Page 6: ...ion COOL DRY horizontal position HEAT position 5 Manual For efficient air conditioning select the upper position for COOL DRY and the lower position for HEAT If the lower position is selected during COOL DRY the vane automatically moves to the horizontal position after 0 5 to 1 hour to prevent any condensation from dripping Swing The vane moves up and down intermittently AUTO Quiet Low Med High Su...

Page 7: ...COOL ECONO COOL and HEAT This ena bles you to select your preferred setting with a single push of the button ECONO COOL OPERATION Press during COOL mode page 4 to start ECONO COOL operation The unit performs swing operation vertically in various cycles according to the temperature of airflow Press again to cancel ECONO COOL operation ECONO COOL operation is canceled when the VANE LONG or POWERFUL ...

Page 8: ... Press to enter the weekly timer setting mode and press and hold for 5 seconds to erase all weekly timer settings Point the remote controller toward the indoor unit 5 Press to turn the weekly timer ON lights When the weekly timer is ON the day of the week whose timer setting is complete will light Press again to turn the weekly timer OFF goes out Note The saved settings will not be cleared when th...

Page 9: ...emi permanent antibacterial and deodorizing characteristics for the filter Nano platinum surpasses the catechin a bioflavonoid that is found in green tea in performance Nano platinum filter uses this compound not only to improve air quality but also to eliminate bacteria and viruses This air filter has a semi permanent lasting effect even after washing it with water Air cleaning filter Electrostat...

Page 10: ...or it is dim The indoor unit does not respond to the remote control signal Are the batteries exhausted Page 3 Is the polarity of the batteries correct Page 3 Are any buttons on the remote controller of other electric appliances being pressed Symptom Explanation Check points Does not cool or heat The room cannot be cooled or heated sufficiently Is the temperature setting appropriate Page 4 Is the f...

Page 11: ...ere the reception is weak provide greater space between the outdoor unit and the antenna of the affected device if operation of the air conditioner interferes with radio or TV reception 1 Set to the highest temperature in manual COOL mode and operate for 3 to 4 hours Page 4 This dries the inside of the unit Moisture in the air conditioner contributes to growth of fungi such as mold 2 Press to stop...

Page 12: ... ถูกวิธี อาจเป นสาเหตุให เกิดอันตรายอย าง รุนแรง ขึ นอยู กับสภาพการใช งานนั นๆ ไม ควรให บุคคล รวมทั งเด กเล ก ที มีสภาพร างกายไม แข งแรง สภาพการรับรู หรือจิตใจไม ปกติ หรือขาดประสบการณ และความรู ความเข าใจ นำอุปกรณ นี ไปใช งาน เว นแต จะอยู ในการควบคุมดูแล หรือได รับคำแนะนำในการใช งานจากผู ที รับผิดชอบต อความปลอดภัย ของบุคคลนั นๆ ได เด กเล กควรได รับการดูแลเพื อป องกันไม ให นำอุปกรณ นี ไปเล น อย าสอ...

Page 13: ...ด ถ าของเหลวจากแบตเตอรี รั วออกมาเป อนผิว เสื อผ า ให ล างออกด วยน ำสะอาด หากของเหลวจากแบตเตอรี เข าตา ให ล างออกด วยน ำสะอาด และ ปรึกษาแพทย โดยทันที ควรตรวจให แน ใจว าพื นที นั นจะมีการระบายอากาศที ดีขณะที เครื อง ปรับอากาศทํางานพร อมกับเครื องใช ที มีการเผาไหม การระบายอากาศที ไม ดีเพียงพออาจทําให เกิดภาวะขาดออกซิเจนได สับเบรกเกอร ลง หากท านได ยินเสียงฟ าร อง และมีความเป นไปได ที จะเกิดฟ าผ า เคร...

Page 14: ...ด แนวนอน หน า 5 ติดตั งที วางรีโมทคอนโทรลใน ตําแหน งที เครื องภายในบ าน สามารถรับสัญญาณได เมื อไม ใช งานรีโมทคอนโทรล โปรดเก บไว ที แท นเสียบนี ส วนแสดงผล 3 กดปุ ม DAY เพื อตั งค าวันที ใช รีโมทคอนโทรลที จัดเตรียมมา กับเครื องเท านั น ห ามใช รีโมทคอนโทรลอันอื น หากติดตั งเครื องในบ าน 2 เครื องขึ น ไปไว ใกล เคียงกัน เครื องในบ าน เครื องใดเครื องหนึ งซึ งไม ต องการให ทํางานอาจมีการตอบสนองต อ รีโมทค...

Page 15: ...ะการทำงาน อุณหภูมิห อง เครื องปรับอากาศกำลังปรับอุณหภูมิ ให ได อุณหภูมิตามที ตั งไว สูงกว าอุณหภูมิที ตั งไว อย างน อย 2 องศา เซลเซียส อุณหภูมิห องใกล เคียงกับอุณหภูมิตาม ที ตั งไว ต ำกว าอุณหภูมิที ตั งไว ประมาณ 1 หรือ 2 องศา เซลเซียส สว าง ไม สว าง ไฟแสดงการทํางาน ระบบการทำงานฉุกเฉิน เมื อไม สามารถใช งานรีโมทคอนโทรลได ท านสามารถใช ระบบการทํางานฉุกเฉินได โดยการกดสวิตช การทํางานฉุกเฉิน E O SW ที เ...

Page 16: ...ลังแรง POWERFUL ระบบพลังแรง POWERFUL จะถูกยกเลิกโดยอัตโนมัติภายใน 15 นาที หรือเมื อ กดปุ มเป ด ป ดเครื อง ON OFF ปุ มควบคุมความเร วใบพัด FAN ปุ มระบบ ทำความเย นแบบ ECONO COOL หรือปุ มระบบทำความเย นแบบ i save ระบบพลังแรง POWERFUL การปรับทิศทางและความเร วของลม อัตโนมัติ เงียบ ต ำ กลาง สูง สูงสุด กดปุ ม เพื อเลือกทิศทางลม เมื อกดปุ มแต ละครั ง ทิศทางลม จะเปลี ยนไปตามลำดับดังนี เสียงบิ บสั นๆ 2 ครั งจ...

Page 17: ...ถึงลำดับการ ทำงานของการตั งเวลา หากกระแสไฟฟ าขัดข องในขณะโปรแกรมการตั งเวลาเป ดป ด ON OFF ทำงานอยู ดู หน า 4 ฟ งก ชันการเริ มต นการทำงานใหม โดยอัตโนมัติ การตั งเวลาเป ด ป ดเครื อง การตั งเวลาON OFF ระบบ i save 1 กดปุ ม ระหว างอยู ในโหมด COOL ECONO COOL หรือ HEAT เพื อเลือกโหมด i save 2 ตั งอุณหภูมิ ความเร วพัดลม และทิศทางลม เพียงแค กด สามารถบันทึกการตั งค าได สองกลุ ม กลุ มหนึ งสําหรับ COOL ECONO ...

Page 18: ... า ไม ต องกด ทุกครั งสำหรับแต ละค า สามารถกด เพียงครั งเดียวหลังจากตั ง ค าทั งหมดเสร จแล ว ค าการตั งเวลารายสัปดาห ทั งหมดจะถูกบันทึกไว กด เพื อเข าสู โหมดการตั งเวลารายสัปดาห แล วกด ค างไว 5 วินาที โดยชี รีโมทคอนโทรลไปที เครื องภายในบ าน เพื อลบค าการตั งเวลารายสัปดาห ทั งหมด 5 กด เพื อเป ดการตั งเวลารายสัปดาห จะสว างขึ น เมื อเป ดการตั งเวลารายสัปดาห วันในรอบสัปดาห ที ตั งค าไว แล วจะสว างขึ น ...

Page 19: ...ือบถาวร ถือว านาโนแพลตินัมมีประสิทธิภาพเหนือกว าสาร คาเตคิน สารไบโอฟลาโวนอยด ที พบในชาเขียว แผ นกรองนาโนแพลตินัมไม เพียงแต ใช สารประกอบนี ในการปรับคุณภาพอากาศเท านั น ยังใช กำจัดเชื อแบคทีเรียและไวรัสอีกด วย แผ นกรองอากาศนี มีประสิทธิภาพในการกรองอากาศได เกือบถาวรแม ว าจะผ านการล างทำ ความสะอาดด วยน ำแล วก ตาม แผ นกรองฟอกอากาศ แผ นกรองที มีเอนไซม ต านสารก ออาการแพ แบบอิเล กโทรสเตติก ทุกๆ 3 เดือน กำ...

Page 20: ...รับผลกระทบอาจจำเป นต องใช เครื องขยายสัญญาณ เมื อได ยินเสียงผิดปกติ เมื อท านคิดว าเครื องปรับอากาศของท านมีป ญหา อาการ รายละเอียดและจุดตรวจสอบ เครื องภายในบ าน เครื องปรับอากาศไม ทำงาน สับเบรกเกอร ขึ นหรือยัง เสียบปลั กไฟหรือยัง ตั งเวลาเป ดเครื องไว หรือไม หน า 6 ไฟ LED ทุกดวงของเครื องภายใน บ านกําลังกะพริบ ใส บานเกล ดปรับทิศทางลมขึ น ลงถูกต องหรือไม หน า 8 บานเกล ดปรับทิศทางลมขึ น ลงไม เคลื อน...

Page 21: ...อสายดินถูกต องแล ว 4 ดู การเตรียมตัวก อนใช งาน และปฏิบัติตามคำแนะนำ หน า 3 เมื อไม ได ใช เครื องปรับอากาศเป นเวลานาน รุ น MSZ SGH24VA ขนาด สูง กว าง ลึก มม เครื องภายในบ าน 325 1100 238 เครื องภายนอกบ าน 880 840 330 น ำหนัก กก เครื องภายในบ าน 16 เครื องภายนอกบ าน 53 หมายเหตุ 1 เงื อนไขการประเมิน ทำความเย น ภายในบ าน 27 C DB 19 C WB ภายนอกบ าน 35 C DB ทำความร อน ภายในบ าน 20 C DB ภายนอกบ าน 7 C DB...

Page 22: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN SG79F558H01 ...

Reviews: