background image

En-2

 CAUTION

Do not touch the air inlet or the aluminum 

fi

 ns of the indoor/

outdoor unit.

•  This may cause injury.

Do not use insecticides or 

fl

 ammable sprays on the unit.

•  This may cause a 

fi

 re or deformation of the unit.

Do not expose pets or houseplants to direct air

fl

 ow.

•  This may cause injury to the pets or plants.

Do not place other electric appliances or furniture under the 

indoor/outdoor unit.

•  Water may drip down from the unit, which may cause damage 

or malfunction.

Do not leave the unit on a damaged installation stand.

•  The unit may fall and cause injury.

Do not step on an unstable bench to operate or clean the 

unit.

•  This may cause injury if you fall down.

Do not pull the power cord.

•  This may cause a portion of the core wire to break, which may 

cause overheating or 

fi

 re.

Do not charge or disassemble the batteries, and do not 

throw them into a 

fi

 re.

•  This may cause the batteries to leak, or cause a 

fi

 re or explo-

sion.

Do not operate the unit for more than 4 hours at high hu-

midity (80% RH or more) and/or with windows or outside 

door left open.

•  This may cause the water condensation in the air conditioner, 

which may drip down, wetting or damaging the furniture.

•  The water condensation in the air conditioner may contribute 

to growth of fungi, such as mold.

Do not use the unit for special purposes, such as storing 

food, raising animals, growing plants, or preserving preci-

sion devices or art objects.

•  This may cause deterioration of quality, or harm to animals 

and plants.

Do not expose combustion appliances to direct air

fl

 ow.

•  This may cause incomplete combustion.

Never put batteries in your mouth for any reason to avoid 

accidental ingestion.

•  Battery ingestion may cause choking and/or poisoning.

Before cleaning the unit, switch it OFF and disconnect the 

power plug or turn the breaker OFF.

•  This may cause injury, since the fan inside rotates at high 

speeds during operation.

When the unit will be unused for a long time, disconnect the 

power plug or turn the breaker OFF.

•  The unit may accumulate dirt, which may cause overheating 

or 

fi

 re.

Replace all batteries of the remote controller with new ones 

of the same type.

•  Using an old battery together with a new one may cause 

overheating, leakage, or explosion.

If the battery 

fl

 uid comes in contact with your skin or clothes, 

wash them thoroughly with clean water.

•  If the battery 

fl

 uid comes in contact with your eyes, wash them 

thoroughly with clean water and immediately seek medical 

attention.

Ensure that the area is well-ventilated when the unit is oper-

ated together with a combustion appliance.

•  Inadequate ventilation may cause oxygen starvation.

Turn the breaker OFF when you hear thunder and there is a 

possibility of a lightning strike.

•  The unit may be damaged if lightning strikes.

After the air conditioner is used for several seasons, per-

form inspection and maintenance in addition to normal 

cleaning.

•  Dirt or dust in the unit may create an unpleasant odor, con-

tribute to growth of fungi, such as mold, or clog the drain pas-

sage, and cause water to leak from the indoor unit. Consult 

your dealer for inspection and maintenance, which require 

specialized knowledge and skills.

 WARNING

Consult your dealer for installing the air conditioner. 

•  It should not be installed by the user since installation requires 

specialized knowledge and skills. An improperly installed air 

conditioner may cause water leakage, 

fi

 re, or electric shock.

Provide a dedicated power supply for the air conditioner.

•  A non-dedicated power supply may cause overheating or 

fi

 re.

Do not install the unit where 

fl

 ammable gas could leak.

•  If gas leaks and accumulates around the outdoor unit, it may 

cause an explosion.

Earth the unit correctly.

•  Do not connect the earth wire to a gas pipe, water pipe, light-

ning rod, or a telephone ground wire. Improper earthing may 

cause electric shock.

 CAUTION

Install an earth leakage breaker depending on the installa-

tion location of the air conditioner (such as highly humid 

areas).

•  If an earth leakage breaker is not installed, it may cause electric 

shock.

Ensure that the drain water is properly drained.

•  If the drain passage is improper, water may drip down from 

the indoor/outdoor unit, wetting and damaging the furniture.

In case of an abnormal condition

  Immediately stop operating the air conditioner and consult your dealer.

S

AFETY PRECAUTIONS

For installation

 IMPORTANT

Dirty 

fi

 lters cause condensation in the air conditioner which will con-

tribute to the growth of fungi such as mold. It is therefore recommended 

to clean air 

fi

 lters every 2 weeks.

Do not operate switches with wet hands.

•  This may cause electric shock.

Do not clean the air conditioner with water or place an object 

that contains water, such as a 

fl

 ower vase, on it.

•  This may cause 

fi

 re or electric shock.

Do not step on or place any object on the outdoor unit.

•  This may cause injury if you or the object falls down.

Summary of Contents for Mr.Slim MSZ-SGH24VA

Page 1: ...SPLIT TYPE AIR CONDITIONERS INDOOR UNIT MSZ SGH24VA English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating in structions before use ...

Page 2: ...t handling could cause serious hazard depending on the conditions This appliance is not intended for use by persons including children with reduced physical sensory or mental capabili ties or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that th...

Page 3: ...attery fluid comes in contact with your eyes wash them thoroughly with clean water and immediately seek medical attention Ensure that the area is well ventilated when the unit is oper ated together with a combustion appliance Inadequate ventilation may cause oxygen starvation Turn the breaker OFF when you hear thunder and there is a possibility of a lightning strike The unit may be damaged if ligh...

Page 4: ...s when pressed longer Indoor unit Remote controller Outdoor units may be different in appearance 1 Remove the front lid 2 Insert AAA alkaline batteries 3 Install the front lid 4 Press RESET Air cleaning filter Electrostatic anti al lergy enzyme filter Signal transmitting section Distance of signal About 6 m Beep s is are heard from the indoor unit when the signal is received Operation display sect...

Page 5: ...Press or to set the temperature Each press raises or lowers the temperature by 1 C Press to stop the operation The same setting is selected the next time by simply pressing Auto restart function If a power failure occurs or the main power is turned off during operation Auto restart function automatically starts operation in the same mode as the one set with the remote controller just before the sh...

Page 6: ...ion COOL DRY horizontal position HEAT position 5 Manual For efficient air conditioning select the upper position for COOL DRY and the lower position for HEAT If the lower position is selected during COOL DRY the vane automatically moves to the horizontal position after 0 5 to 1 hour to prevent any condensation from dripping Swing The vane moves up and down intermittently AUTO Quiet Low Med High Su...

Page 7: ...COOL ECONO COOL and HEAT This ena bles you to select your preferred setting with a single push of the button ECONO COOL OPERATION Press during COOL mode page 4 to start ECONO COOL operation The unit performs swing operation vertically in various cycles according to the temperature of airflow Press again to cancel ECONO COOL operation ECONO COOL operation is canceled when the VANE LONG or POWERFUL ...

Page 8: ... Press to enter the weekly timer setting mode and press and hold for 5 seconds to erase all weekly timer settings Point the remote controller toward the indoor unit 5 Press to turn the weekly timer ON lights When the weekly timer is ON the day of the week whose timer setting is complete will light Press again to turn the weekly timer OFF goes out Note The saved settings will not be cleared when th...

Page 9: ...emi permanent antibacterial and deodorizing characteristics for the filter Nano platinum surpasses the catechin a bioflavonoid that is found in green tea in performance Nano platinum filter uses this compound not only to improve air quality but also to eliminate bacteria and viruses This air filter has a semi permanent lasting effect even after washing it with water Air cleaning filter Electrostat...

Page 10: ...or it is dim The indoor unit does not respond to the remote control signal Are the batteries exhausted Page 3 Is the polarity of the batteries correct Page 3 Are any buttons on the remote controller of other electric appliances being pressed Symptom Explanation Check points Does not cool or heat The room cannot be cooled or heated sufficiently Is the temperature setting appropriate Page 4 Is the f...

Page 11: ...ere the reception is weak provide greater space between the outdoor unit and the antenna of the affected device if operation of the air conditioner interferes with radio or TV reception 1 Set to the highest temperature in manual COOL mode and operate for 3 to 4 hours Page 4 This dries the inside of the unit Moisture in the air conditioner contributes to growth of fungi such as mold 2 Press to stop...

Page 12: ... ถูกวิธี อาจเป นสาเหตุให เกิดอันตรายอย าง รุนแรง ขึ นอยู กับสภาพการใช งานนั นๆ ไม ควรให บุคคล รวมทั งเด กเล ก ที มีสภาพร างกายไม แข งแรง สภาพการรับรู หรือจิตใจไม ปกติ หรือขาดประสบการณ และความรู ความเข าใจ นำอุปกรณ นี ไปใช งาน เว นแต จะอยู ในการควบคุมดูแล หรือได รับคำแนะนำในการใช งานจากผู ที รับผิดชอบต อความปลอดภัย ของบุคคลนั นๆ ได เด กเล กควรได รับการดูแลเพื อป องกันไม ให นำอุปกรณ นี ไปเล น อย าสอ...

Page 13: ...ด ถ าของเหลวจากแบตเตอรี รั วออกมาเป อนผิว เสื อผ า ให ล างออกด วยน ำสะอาด หากของเหลวจากแบตเตอรี เข าตา ให ล างออกด วยน ำสะอาด และ ปรึกษาแพทย โดยทันที ควรตรวจให แน ใจว าพื นที นั นจะมีการระบายอากาศที ดีขณะที เครื อง ปรับอากาศทํางานพร อมกับเครื องใช ที มีการเผาไหม การระบายอากาศที ไม ดีเพียงพออาจทําให เกิดภาวะขาดออกซิเจนได สับเบรกเกอร ลง หากท านได ยินเสียงฟ าร อง และมีความเป นไปได ที จะเกิดฟ าผ า เคร...

Page 14: ...ด แนวนอน หน า 5 ติดตั งที วางรีโมทคอนโทรลใน ตําแหน งที เครื องภายในบ าน สามารถรับสัญญาณได เมื อไม ใช งานรีโมทคอนโทรล โปรดเก บไว ที แท นเสียบนี ส วนแสดงผล 3 กดปุ ม DAY เพื อตั งค าวันที ใช รีโมทคอนโทรลที จัดเตรียมมา กับเครื องเท านั น ห ามใช รีโมทคอนโทรลอันอื น หากติดตั งเครื องในบ าน 2 เครื องขึ น ไปไว ใกล เคียงกัน เครื องในบ าน เครื องใดเครื องหนึ งซึ งไม ต องการให ทํางานอาจมีการตอบสนองต อ รีโมทค...

Page 15: ...ะการทำงาน อุณหภูมิห อง เครื องปรับอากาศกำลังปรับอุณหภูมิ ให ได อุณหภูมิตามที ตั งไว สูงกว าอุณหภูมิที ตั งไว อย างน อย 2 องศา เซลเซียส อุณหภูมิห องใกล เคียงกับอุณหภูมิตาม ที ตั งไว ต ำกว าอุณหภูมิที ตั งไว ประมาณ 1 หรือ 2 องศา เซลเซียส สว าง ไม สว าง ไฟแสดงการทํางาน ระบบการทำงานฉุกเฉิน เมื อไม สามารถใช งานรีโมทคอนโทรลได ท านสามารถใช ระบบการทํางานฉุกเฉินได โดยการกดสวิตช การทํางานฉุกเฉิน E O SW ที เ...

Page 16: ...ลังแรง POWERFUL ระบบพลังแรง POWERFUL จะถูกยกเลิกโดยอัตโนมัติภายใน 15 นาที หรือเมื อ กดปุ มเป ด ป ดเครื อง ON OFF ปุ มควบคุมความเร วใบพัด FAN ปุ มระบบ ทำความเย นแบบ ECONO COOL หรือปุ มระบบทำความเย นแบบ i save ระบบพลังแรง POWERFUL การปรับทิศทางและความเร วของลม อัตโนมัติ เงียบ ต ำ กลาง สูง สูงสุด กดปุ ม เพื อเลือกทิศทางลม เมื อกดปุ มแต ละครั ง ทิศทางลม จะเปลี ยนไปตามลำดับดังนี เสียงบิ บสั นๆ 2 ครั งจ...

Page 17: ...ถึงลำดับการ ทำงานของการตั งเวลา หากกระแสไฟฟ าขัดข องในขณะโปรแกรมการตั งเวลาเป ดป ด ON OFF ทำงานอยู ดู หน า 4 ฟ งก ชันการเริ มต นการทำงานใหม โดยอัตโนมัติ การตั งเวลาเป ด ป ดเครื อง การตั งเวลาON OFF ระบบ i save 1 กดปุ ม ระหว างอยู ในโหมด COOL ECONO COOL หรือ HEAT เพื อเลือกโหมด i save 2 ตั งอุณหภูมิ ความเร วพัดลม และทิศทางลม เพียงแค กด สามารถบันทึกการตั งค าได สองกลุ ม กลุ มหนึ งสําหรับ COOL ECONO ...

Page 18: ... า ไม ต องกด ทุกครั งสำหรับแต ละค า สามารถกด เพียงครั งเดียวหลังจากตั ง ค าทั งหมดเสร จแล ว ค าการตั งเวลารายสัปดาห ทั งหมดจะถูกบันทึกไว กด เพื อเข าสู โหมดการตั งเวลารายสัปดาห แล วกด ค างไว 5 วินาที โดยชี รีโมทคอนโทรลไปที เครื องภายในบ าน เพื อลบค าการตั งเวลารายสัปดาห ทั งหมด 5 กด เพื อเป ดการตั งเวลารายสัปดาห จะสว างขึ น เมื อเป ดการตั งเวลารายสัปดาห วันในรอบสัปดาห ที ตั งค าไว แล วจะสว างขึ น ...

Page 19: ...ือบถาวร ถือว านาโนแพลตินัมมีประสิทธิภาพเหนือกว าสาร คาเตคิน สารไบโอฟลาโวนอยด ที พบในชาเขียว แผ นกรองนาโนแพลตินัมไม เพียงแต ใช สารประกอบนี ในการปรับคุณภาพอากาศเท านั น ยังใช กำจัดเชื อแบคทีเรียและไวรัสอีกด วย แผ นกรองอากาศนี มีประสิทธิภาพในการกรองอากาศได เกือบถาวรแม ว าจะผ านการล างทำ ความสะอาดด วยน ำแล วก ตาม แผ นกรองฟอกอากาศ แผ นกรองที มีเอนไซม ต านสารก ออาการแพ แบบอิเล กโทรสเตติก ทุกๆ 3 เดือน กำ...

Page 20: ...รับผลกระทบอาจจำเป นต องใช เครื องขยายสัญญาณ เมื อได ยินเสียงผิดปกติ เมื อท านคิดว าเครื องปรับอากาศของท านมีป ญหา อาการ รายละเอียดและจุดตรวจสอบ เครื องภายในบ าน เครื องปรับอากาศไม ทำงาน สับเบรกเกอร ขึ นหรือยัง เสียบปลั กไฟหรือยัง ตั งเวลาเป ดเครื องไว หรือไม หน า 6 ไฟ LED ทุกดวงของเครื องภายใน บ านกําลังกะพริบ ใส บานเกล ดปรับทิศทางลมขึ น ลงถูกต องหรือไม หน า 8 บานเกล ดปรับทิศทางลมขึ น ลงไม เคลื อน...

Page 21: ...อสายดินถูกต องแล ว 4 ดู การเตรียมตัวก อนใช งาน และปฏิบัติตามคำแนะนำ หน า 3 เมื อไม ได ใช เครื องปรับอากาศเป นเวลานาน รุ น MSZ SGH24VA ขนาด สูง กว าง ลึก มม เครื องภายในบ าน 325 1100 238 เครื องภายนอกบ าน 880 840 330 น ำหนัก กก เครื องภายในบ าน 16 เครื องภายนอกบ าน 53 หมายเหตุ 1 เงื อนไขการประเมิน ทำความเย น ภายในบ าน 27 C DB 19 C WB ภายนอกบ าน 35 C DB ทำความร อน ภายในบ าน 20 C DB ภายนอกบ าน 7 C DB...

Page 22: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN SG79F558H01 ...

Reviews: