background image

En-8

Even if these items are checked, when the unit does not recover from the 

trouble, stop using the air conditioner and consult your dealer.

Symptom

Explanation & Check points

Indoor Unit

The unit cannot be operated.

•  Is the breaker turned on?

•  Is the power supply plug connected?

•  Is the ON timer set? 

 Page 6 

All LED lamps on the indoor 

unit are blinking.

•  Are the horizontal vanes installed correctly?  

 Page 7 

The horizontal vane does not 

move.

•  Are the horizontal vane and the vertical vane 

installed correctly? 

 Page 7 

•  Is the fan guard deformed?

The unit cannot be operated 

for about 3 minutes when 

restarted.

•  This protects the unit according to instruc-

tions  from  the  microprocessor.  Please 

wait.

Mist is discharged from the air 

outlet of the indoor unit.

•  The cool air from the unit rapidly cools mois-

ture in the air inside the room, and it turns 

into mist.

The swing operation of the 

HORIZONTAL VANE is 

suspended for a while, then 

restarted.

•  This is for the swing operation of the HORI-

ZONTAL VANE to be performed normally.

The air flow direction changes 

during operation.

The direction of the horizontal 

vane cannot be adjusted with 

the remote controller.

•  When the unit is operated in COOL or DRY 

mode,  if  the  operation  continues  with  air 

blowing down for 0.5 to 1 hour, the direction 

of the air flow is automatically set to horizon-

tal position to prevent water from condensing 

and dripping.

•  In the heating operation, if the air flow tem-

perature is too low or when defrosting is be-

ing done, the horizontal vane is automatically 

set to horizontal position.

The operation is stopped for 

about 10 minutes in the heat-

ing operation.

•  Defrosting  of  the  outdoor  unit  is  being 

done.

  Since this is completed in max.10 minutes, 

please wait. (When the outside temperature 

is too low and humidity is too high, frost is 

formed.)

The unit starts operation by 

itself when the main power 

is turned on, though it isn’t 

operated with the remote 

controller.

•  These models are equipped with an auto re-

start function. When the main power is turned 

off without stopping the unit with the remote 

controller and is turned on again, the unit 

starts operation automatically in the same 

mode as the one set with the remote control-

ler just before the shutoff of the main power.  

Refer to “Auto restart function” 

 page 4 

.

Outdoor Unit

The fan of the outdoor unit 

does not rotate even though 

the compressor is running. 

Even if the fan starts to rotate, 

it stops soon.

•  When the outside temperature is low dur-

ing  cooling  operation,  the  fan  operates 

intermittently to maintain sufficient cooling 

capacity.

Water leaks from the outdoor 

unit.

•  During COOL and DRY operations, pipe or 

pipe connecting sections are cooled and this 

causes water to condense.

•  In the heating operation, water condensed 

on the heat exchanger drips down.

•  In the heating operation, the defrosting op-

eration makes water frozen on the outdoor 

unit melt and drip down.

White smoke is discharged 

from the outdoor unit.

•  In  the  heating  operation,  vapor  generated 

by the defrosting operation looks like white 

smoke.

Symptom

Explanation & Check points

Remote controller

The display on the remote 

controller does not appear 

or it is dim. The indoor unit 

does not respond to the 

remote control signal.

•  Are the batteries exhausted? 

 Page 3 

•  Is the polarity (+, -) of the batteries correct? 

 Page 3 

•  Are any buttons on the remote controller of 

other electric appliances being pressed?

Does not cool or heat

The room cannot be cooled 

or heated sufficiently.

•  Is  the  temperature  setting  appropriate?  

 Page 4 

•  Is  the  fan  setting  appropriate?  Please 

change fan speed to higher setting. 

   

 Page 5 

•  Are the filters clean? 

 Page 7 

•  Is the fan or heat exchanger of the indoor unit 

clean? 

 Page 7 

•  Are there any obstacles blocking the air inlet 

or outlet of the indoor or outdoor unit?

•  Is a window or door open?

The room cannot be cooled 

sufficiently.

•  When  a  ventilation  fan  or  a  gas  cooker  is 

used in a room, the cooling load increases, 

resulting in an insufficient cooling effect.

•  When  the  outside  temperature  is  high,  the 

cooling effect may not be sufficient.

The room cannot be heated 

sufficiently.

•  When  the  outside  temperature  is  low,  the 

heating effect may not be sufficient.

Air does not blow out soon in 

the heating operation.

•  Please wait as the unit is preparing to blow 

out warm air.

Airflow

The air from the indoor unit 

smells strange.

•  Are the filters clean? 

 Page 7 

•  Is the fan or heat exchanger of the indoor unit 

clean? 

 Page 7 

•  The unit may suck in an odor adhering to the 

wall, carpet, furniture, cloth, etc. and blow it 

out with the air.

Sound

Cracking sound is heard.

•  This sound is generated by the expansion/

contraction  of  the  front  panel,  etc.  due  to 

change in temperature.

“Burbling” sound is heard.

•  This sound is heard when the outside air is 

absorbed from the drain hose by turning on 

the range hood or the ventilation fan, making 

water flowing in the drain hose to spout out.

  This sound is also heard when the outside air 

blows into the drain hose in case the outside 

wind is strong.

Mechanical sound is heard 

from the indoor unit.

•  This is the switching sound in turning on/off 

the fan or the compressor.

The sound of water flowing 

is heard.

•  This is the sound of refrigerant or condensed 

water flowing in the unit.

Hissing sound is sometimes 

heard.

•  This is the sound when the flow of refrigerant 

inside the unit is switched.

In the following cases, stop using the air conditioner and consult your dealer.

•  When water leaks or drips from the indoor unit.

•  When the upper operation indicator lamp blinks.

•  When the breaker trips frequently.

•  The remote control signal is not received in a room where an electronic ON/OFF 

type fluorescent lamp (inverter-type fluorescent lamp, etc.) is used.

•  Operation of the air conditioner interferes with radio or TV reception. An ampli-

fier may be required for the affected device.

•  When an abnormal sound is heard.

W

HEN YOU THINK THAT TROUBLE HAS OCCURRED

Summary of Contents for Mr. Slim MSZ-SGE09VA

Page 1: ...17VA English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating instructions before use คู มือการใช งาน สำหรับลูกค า เพื อสามารถใช เครื องปรับอากาศเครื องนี อย างถูกต องและปลอดภัย ควรมั นใจว าท านได อ านคู มือ การใช เล มนี ก อนใช ไทย ...

Page 2: ...ld cause serious hazard depending on the conditions Do not insert your finger a stick or other objects into the air inlet or outlet This may cause injury since the fan inside rotates at high speeds during operation In case of an abnormal condition such as a burning smell stop the air conditioner and disconnect the power plug or turn the breaker OFF A continued operation in the abnormal state may c...

Page 3: ...ossibility of a lightning strike The unit may be damaged if lightning strikes After the air conditioner is used for several seasons per form inspection and maintenance in addition to normal cleaning Dirt or dust in the unit may create an unpleasant odor con tribute to growth of fungi such as mold or clog the drain pas sage and cause water to leak from the indoor unit Consult your dealer for inspec...

Page 4: ...rrent time NAME OF EACH PART PREPARATION BEFORE OPERATION 1 Press CLOCK 3 Press CLOCK again 2 Press the TIME buttons to set the time Each press increases decreases the time by 1 minute 10 minutes when pressed longer Indoor unit Remote controller Outdoor units may be different in appearance 1 Remove the front lid 2 Insert AAA alkaline batteries 3 Install the front lid 4 Press RESET Air cleaning fil...

Page 5: ...set the temperature Each press raises or lowers the temperature by 1 C Press to stop the operation The same setting is selected the next time by simply pressing Auto restart function If a power failure occurs or the main power is turned off during operation Auto restart function automatically starts operation in the same mode as the one set with the remote controller just before the shutoff of the...

Page 6: ...4 5 SWING FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT I SAVE OPERATION 1 Press during COOL ECONO COOL or HEAT mode to select i save mode 2 Set the temperature fan speed and air flow direction The same setting is selected from the next time by simply pressing Two groups of setting can be saved One for COOL ECONO COOL one for HEAT Select the appropriate temperature fan speed and airflow direction acc...

Page 7: ...lly set 2 C higher it is possible to perform cooling operation with keeping comfort As a result energy can be saved 1 Press or during operation to set the timer ON timer The unit turns ON at the set time OFF timer The unit turns OFF at the set time or blinks Make sure that the current time is set correctly Page 3 2 Press Increase and Decrease to set the time of timer Each press increases or decrea...

Page 8: ... in reverse Close the front panel securely and press the positions indicated by the arrows Hole Hinge Air cleaning filter Anti Allergy Enzyme Filter Back side of air filter Clean every 3 months Soak the filter together with its frame in lukewarm water and rinse it After washing dry it well in shade Install all tabs of the air filter Replace it with a new air cleaning filter every year for best per...

Page 9: ...tion makes water frozen on the outdoor unit melt and drip down White smoke is discharged from the outdoor unit In the heating operation vapor generated by the defrosting operation looks like white smoke Symptom Explanation Check points Remote controller The display on the remote controller does not appear or it is dim The indoor unit does not respond to the remote control signal Are the batteries ...

Page 10: ...de of the unit Moisture in the air conditioner contributes to growth of fungi such as mold 2 Press to stop the operation 3 Turn off the breaker and or disconnect the power sup ply plug 4 Remove all batteries from the remote controller When using the air conditioner again 1 Clean the air filter Page 7 2 Check that the air inlet and outlet of the indoor and outdoor units are not blocked 3 Check that...

Page 11: ...รง สภาพการรับรู หรือจิตใจไม ปกติ หรือขาดประสบการณ และความรู ความเข าใจ นําอุปกรณ นี ไปใช งาน เว นแต จะอยู ในการควบคุมดูแล หรือได รับคําแนะนําในการใช งานจากผู ที รับผิดชอบต อความปลอดภัย ของบุคคลนั นๆ ได เด กเล กควรได รับการดูแลเพื อป องกันไม ให นําอุปกรณ นี ไปเล น อย าสอดนิ ว กิ งไม หรือวัตถุอื นๆ เข าไปในช องลมเข าหรือช องลมออก เนื องจากใบพัดหมุนด วยความเร วสูงในขณะที เครื องทํางาน อาจเป นสาเหตุให...

Page 12: ...ง หากท านได ยินเสียงฟ าร อง และมีความเป นไปได ที จะเกิดฟ าผ า เครื องอาจชํารุด หากโดนฟ าผ า หลังจากใช เครื องปรับอากาศมาเป นเวลานาน ควรตรวจสภาพและทํา การบํารุงรักษานอกเหนือไปจากการทําความสะอาดตามปกติ สิ งสกปรกหรือฝุ นในตัวเครองอาจก อให เกิดกลิ นอันไม พึงประสงค ซึ งมีส วนให เกิดเชื อราได หรืออุดตันทางระบายนํ า และทําให นํ ารั วจาก เครองภายในอาคาร โปรดปรึกษาตัวแทนจําหนายของท าน เพอทําการ ตรวจสอบและบ...

Page 13: ...นเล กๆ 1 ถอดฝาด านหน าออก 2 ใส แบตเตอรี ชนิด อัลคาไลน ขนาด AAA 3 ใส ฝาด านหน ากลับเข าไป 1 กดปุ ม CLOCK 3 กดปุ ม CLOCK อีกครั ง 2 กดปุ ม TIME เพื อตั งเวลา แต ละครั งที กดปุ ม เวลาจะเพิ ม ลด ครั งละ 1 นาที เมื อกดค างไว เวลา จะเพิ ม ลด 10 นาที 4 กดปุ ม RESET ก อนใช งาน เสียบปลั กไฟเข ากับเต ารับ และ หรือสับเบรกเกอร ขึ น à µ µÕ Ë π Õπ µ Èß ªí ÿ π ลักษณะของเครื องภายนอกอาคารบางรุ นอาจแตกต างกันออกไป...

Page 14: ...อง เครื องปรับอากาศกำลังปรับอุณหภูมิ ให ได อุณหภูมิตามที ตั งไว สูงกว าอุณหภูมิที ตั งไว อย างน อย 2 องศา เซลเซียส อุณหภูมิห องใกล เคียงกับอุณหภูมิตาม ที ตั งไว ต ำกว าอุณหภูมิที ตั งไว ประมาณ 1 หรือ 2 องศาเซลเซียส สว าง ไม สว าง ß π ÿ π ËÕ à âß π Õπ â ท านสามารถใช ระบบการทํางานฉุกเฉินได โดยการกดสวิตช การทํางานฉุกเฉิน E O SW ที เครื องภายในอาคาร แต ละครั งที กดปุ ม E O SW โหมดการทํางานจะเปลี ยนไปต...

Page 15: ...COOL และ HEAT ทําให สามารถเลือกการตั งค าตามต องการของท านได โดย กดปุ มเพียงครั งเดียว กดปุ ม เพื อเลือกความเร วใบพัด เมื อกดปุ มแต ละครั ง ความเร ว ของใบพัดจะเปลี ยนไปตามลำดับดังนี เสียงบิ บสั นๆ 2 ครั งจะดังขึ นจากเครื องภายในอาคาร เมื อเลือกการทำงาน แบบอัตโนมัติ AUTO ใช ความเร วพัดลมสูงขึ นเพื อทําให ห องเย น ร อนได อย างมีประสิทธิภาพมากขึ น ขอแนะนําให ลดความเร วพัดลมลง เมื อห องเย น อุ นแล ว ใ...

Page 16: ...ทำงานในระบบนี ก ยังจะคงให ความรู สึกเย นสบายได เหมือนเดิม ด วยเหตุ นี จึงสามารถช วยประหยัดพลังงานได Áπ ECONO COOL µ Èß ªî ªî ËÕß µ Èß ON OFF 1 กดปุ ม หรือ ในขณะที เครื องกำลังทำงานเพื อตั งเวลา การตั งเวลา ON ตัวเครื องจะเป ด ON ตามเวลา ที ตั งไว การตั งเวลา OFF ตัวเครื องจะป ด OFF ตามเวลา ที ตั งไว หรือ กะพริบ ให แน ใจว าได ตั งเวลาป จจุบันไว ถูกต องแล ว หน า 3 2 กดปุ ม เพิ ม และ ลด เพื อตั งเวลา...

Page 17: ...ยงแต ใช สารประกอบนี ในการปรับ คุณภาพอากาศเท านั นยังใช กําจัดเชื อแบคทีเรียและไวรัสอีกด วย แผ นกรองอากาศนี มีประสิทธิภาพในการกรองอากาศได เกือบถาวรแม ว าจะผ านการล างทําความสะอาด ด วยน ำแล วก ตาม ºàπ ÕßøÕ Õ ºàπ Õß Ë Õπ åµâ π Ëß àÕ Àâ Õ æâ â πÀ ß Õß ºàπ ÕßÕ ทำความสะอาดทุก 3 เดือน แช แผ นกรองพร อมโครงในน ำค อนข าง อุ น แล วล างทำความสะอาด หลังจากล างเสร จ ผึ งให แห งในที ร ม และใส กลับเข าไปยังตำแหน ...

Page 18: ...มระบบการทำงานที ได ถูกตั งไว ในรีโมทคอนโทรลก อนที ไฟหลักจะถูกตัด ดู ฟ งก ชันการเริ มต นการทำงานใหม โดยอัตโนมัติ หน า 4 เครื องภายนอกอาคาร พัดลมเครองภายนอกอาคารไม หมุน แม คอมเพรสเซอร กําลังทํางานอยู แม พัดลมจะเริ มต นหมุนก หยุดลงใน เวลาไม นาน เมออุณหภูมิภายนอกลดต ำระหว างอยู ในโหมดทํา ความเย น พัดลมจะหยุดทํางานเป นช วงๆเพอรักษา ความสามารถในการทําความเย นให พอเพียง เกิดน ำรั วจากเครื องภายนอก ระหว า...

Page 19: ...Ë â ËÕߪ Õ Õ Èß 1 ทำความสะอาดแผ นกรองอากาศ หน า 7 2 ตรวจสอบว าไม มีสิ งกีดขวางที ช องลมเข า และช องลมออกของเครื อง ภายในและภายนอกอาคาร 3 ตรวจสอบว าต อสายดินถูกต องแล วภายในและภายนอกอาคาร 4 ดู การเตรียมตัวก อนใช งาน และปฏิบัติตามคําแนะนํา หน า 3 ËÕ à â â ËÕߪ Õ ªìπ π π การรักษาสิ งแวดล อม เครื องปรับอากาศ Mitsubishi Electric ถูกออกแบบมาเพื อเป นมิตรกับสิ งแวดล อม ส วนประกอบที ทำจากพลาสติกสามารถนำกล...

Page 20: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN SG79F319H03 ...

Reviews: