3-7. CAPACITY CORRECTION TABLE BY TEMPERATURE
1) COOLING CAP
ACITY
(1) MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA-1 MUZ-GE18NA-1
Model
Indoor
air
Outdoor
intake
air
DB
temperature
(˚F)
IWB
(˚
F)
75
85
95
105
11
5
TC
SHC
TPC
TC
SHC
TPC
TC
SHC
TPC
TC
SHC
TPC
TC
SHC
TPC
MUZ-GE09NA
71
11.0
7.6
0.59
10.3
7.1
0.64
9.7
6.6
0.69
9.0
6.2
0.73
8.3
5.7
0.76
67
10.4
8.6
0.55
9.7
8.0
0.61
9.0
7.4
0.66
8.4
6.9
0.70
7.7
6.3
0.73
63
9.8
9.4
0.53
9.1
8.7
0.58
8.5
8.1
0.63
7.7
7.3
0.67
7.0
6.7
0.70
MUZ-GE12NA
71
14.7
8.9
0.85
13.7
8.3
0.94
12.9
7.8
1.01
12.0
7.3
1.06
11.0
6.7
1.10
67
13.9
10.3
0.81
13.0
9.6
0.89
12.0
8.9
0.96
11.2
8.3
1.02
10.3
7.6
1.07
63
13.1
11.4
0.77
12.1
10.6
0.85
11.3
9.9
0.92
10.3
9.0
0.98
9.4
8.2
1.02
MUZ-GE15NA-1
71
17.2
11.4
0.96
16.0
10.7
1.05
15.1
10.0
1.13
14.0
9.3
1.19
12.9
8.6
1.24
67
16.2
13.0
0.91
15.1
12.1
1.00
14.0
11.2
1.08
13.0
10.4
1.14
12.0
9.6
1.20
63
15.3
14.2
0.86
14.1
13.2
0.96
13.2
12.3
1.03
12.0
11.2
1.10
10.9
10.2
1.14
MUZ-GE18NA-1
71
21.1
12.2
1.46
19.7
11.4
1.60
18.5
10.7
1.72
17.2
9.9
1.81
15.8
9.1
1.89
67
20.0
14.2
1.38
18.6
13.2
1.52
17.2
12.2
1.64
16.0
11.4
1.74
14.7
10.4
1.82
63
18.7
15.8
1.31
17.4
14.7
1.45
16.2
13.6
1.57
14.7
12.4
1.67
13.4
11.3
1.74
NOTE
: 1.
IWB:
Intake
air
wet-bulb
temperature
TC:
Total
Capacity
(
×10
3
Btu/h)
SHC: Sensible
Heat
Capacity
(
×10
3
Btu/h)
TPC:
Total
Power
Consumption
(kW)
2.
SHC
is
based
on
80˚F
of
indoor
Intake
air
DB
temperature.