Instructions:

 

Air outlet and Fan (before cleaning, make sure that the fan is stopped)

C

LEANING

1

Turn the horizontal vanes down-

ward. Then, remove the upper 

vane as shown in 

➀ 

and 

.

•  Repeat 

➀ 

and 

➁ 

for the lower vane.

2

Swing out the two vertical vanes 

one by one.

4

Put the vertical vanes back to their 

original positions correctly one by 

one, into their respective guide.

•  Push the vanes until they click into place.

3

Clean the air outlet and fan.

•  Wipe with a soft dry cloth.

5

Install the horizontal vanes by 

following the removal procedure 

in reverse.

•  If  the  horizontal  vanes  are  not  installed 

correctly, all LED lamps blink when power 

is turned on.

•  Switch off the power supply or turn off the breaker before cleaning.

•  Be careful not to touch the metal parts with your hands.

•  Do not use benzine, thinner, polishing powder, or insecticide.

•  Use only diluted mild detergents.

•  Do not expose parts to direct sunlight, heat, or fi re to dry.

•  Do not use water hotter than 50°C.

Note:

Do not apply excessive force to the fan.

Front panel

Hole

Hinge

Upper vane

Unlock

Air fi lter (Nano platinum fi lter)

• 

 

Clean every 2 weeks

 

•  Remove dirt by a vacuum cleaner, or rinse with water.

•  After washing with water, dry it well in shade.

What is “Nano platinum fi lter” ?

Nano platinum is a ceramic particle that includes a platinum nanoparticle. 

The particles are incorporated into the fi lter material, which results in pro-

viding semi-permanent antibacterial and deodorizing characteristics for the 

fi lter. Nano platinum surpasses the catechin (a biofl avonoid that is found 

in green tea) in performance. Nano platinum fi lter uses this compound not 

only to improve air quality but also to eliminate bacteria and viruses. This air 

fi lter has a semi-permanent lasting effect even after washing it with water.

Air cleaning fi lter 

(Electrostatic anti-allergy enzyme fi lter)

Every 3 months:

•  Remove dirt by a vacuum cleaner.

When dirt cannot be removed by vacuum cleaning:

• 

Soak the fi lter and its frame in lukewarm water before rinsing it.

• 

After washing, dry it well in shade.

Every year:

•  Replace it with a new air cleaning fi lter for best performance.

•  Parts Number 

 MAC-2310FT-E 

 (with frame)

•  Parts Number 

 MAC-2410FT-E 

 (No frame)

 Important

• 

Clean the fi lters regularly for best performance and to 

reduce power consumption.

• 

Dirty  fi lters  cause  condensation  in  the  air  conditioner 

which  will  contribute  to  the  growth  of  fungi  such  as 

mold.  It  is  therefore  recommended  to  clean  air  fi lters 

every 2 weeks.

1. Lift the front panel until a “click” is heard.
2. Hold the hinges and pull to remove as shown in the left illustration.

•  Wipe with a soft dry cloth or rinse it with water.

•  Do not soak it in water for more than two hours.

•  Dry it well in shade.

3. Install the panel by following the removal procedure in reverse. Close the front 

panel securely and press the positions indicated by the arrows.

Guide (catch)

SG79F400H03_en.indd   8

2009/11/19   17:23:26

Summary of Contents for Mr.SLIM MS-SFF18VC

Page 1: ...TIONERS INDOOR UNIT MS SFF18VC MS SFF24VC English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating in structions before use SG79F400H03_Cover indd 1 2009 11 19 17 20 39 ...

Page 2: ...onditions Do not insert your finger a stick or other objects into the air inlet or outlet This may cause injury since the fan inside rotates at high speeds during operation In case of an abnormal condition such as a burning smell stop the air conditioner and disconnect the power plug or turn the breaker OFF A continued operation in the abnormal state may cause a malfunction fire or electric shock In...

Page 3: ...ning strike The unit may be damaged if lightning strikes After the air conditioner is used for several seasons per form inspection and maintenance in addition to normal cleaning Dirt or dust in the unit may create an unpleasant odor con tribute to growth of fungi such as mold or clog the drain pas sage and cause water to leak from the indoor unit Consult your dealer for inspection and maintenance ...

Page 4: ...h press increases decreases the time by 1 minute 10 minutes when pressed longer Indoor unit Remote controller Outdoor units may be different in appearance 1 Remove the front lid 2 Insert AAA alkaline batteries 3 Install the front lid 4 Press RESET Air cleaning filter Electrostatic anti allergy enzyme filter Remote controller holder Signal transmitting section Distance of signal About 6 m Beep s is a...

Page 5: ...ion mode Each press changes mode in the following order 3 Press or to set the temperature Each press raises or lowers the temperature by 1 C Press to stop the operation The same setting is selected the next time by simply pressing Auto restart function If a power failure occurs or the main power is turned off during operation Auto restart function automatically starts operation in the same mode as...

Page 6: ...automatically moves to the horizontal position after 0 5 to 1 hour to prevent any condensation from dripping Swing The vane moves up and down intermittently AUTO Low Med High AUTO 1 2 3 4 5 SWING SWING LONG OPERATION Press to start LONG operation Fan speed increases and the horizontal vane moves to the position for LONG mode Air reaches to longer distance Press again to cancel LONG operation LONG ...

Page 7: ... cooling operation with keeping comfort As a result energy can be saved 1 Press or during operation to set the timer ON timer The unit turns ON at the set time OFF timer The unit turns OFF at the set time or blinks Make sure that the current time and day are set correctly Page 3 2 Press Increase and Decrease to set the time of timer Each press increases or decreases the set time by 10 minutes Set ...

Page 8: ...eekly timer setting mode and press and hold for 5 seconds to erase all weekly timer settings Point the remote controller toward the indoor unit 5 Press to turn the weekly timer ON lights When the weekly timer is ON the day of the week whose timer setting is complete will light Press again to turn the weekly timer OFF goes out Note The saved settings will not be cleared when the weekly timer is tur...

Page 9: ...to the filter material which results in pro viding semi permanent antibacterial and deodorizing characteristics for the filter Nano platinum surpasses the catechin a bioflavonoid that is found in green tea in performance Nano platinum filter uses this compound not only to improve air quality but also to eliminate bacteria and viruses This air filter has a semi permanent lasting effect even after washin...

Page 10: ...ontroller of other electric appliances being pressed Symptom Explanation Check points Does not cool The room cannot be cooled sufficiently Is the temperature setting appropriate Page 4 Is the fan setting appropriate Please change fan speed to higher setting Page 5 Are the filters clean Page 8 Is the fan or heat exchanger of the indoor unit clean Are there any obstacles blocking the air inlet or outl...

Page 11: ...es the inside of the unit Moisture in the air conditioner contributes to growth of fungi such as mold 2 Press to stop the operation 3 Turn off the breaker and or disconnect the power sup ply plug 4 Remove all batteries from the remote controller When using the air conditioner again 1 Clean the air filter Page 8 2 Check that the air inlet and outlet of the indoor and outdoor units are not blocked 3 ...

Page 12: ...นอยู กับสภาพการใช งานนั นๆ อย าสอดนิ ว กิ งไม หรือวัตถุอื นๆ เข าไปในช องลมเข าหรือช องลมออก เน องจากใบพัดหมุนด วยความเร วสูงในขณะที เครื องทํางาน อาจ เป นสาเหตุให เกิดอาการบาดเจ บได เมื อเกิดสิ งผิดปกติ เช น กลิ นเหม นไหม เป นต น ให ป ดเครื องปรับ อากาศและถอดปลั กไฟ หรือสับเบรกเกอร ลง หากเครื องปรับอากาศยังถูกใช งานต อไปทั งๆ ที อยู ในสภาพผิดปกติ อาจเป นสาเหตุให เครื องทํางานผิดพลาด ไฟไหม หรือไฟด...

Page 13: ...ากาศที ไม ดีเพียงพออาจทําให เกิดภาวะขาดออกซิเจนได สับเบรกเกอร ลง หากท านได ยินเสียงฟ าร อง และมีความเป นไปได ที จะ เกิดฟ าผ า เครื องอาจชํารุด หากโดนฟ าผ า หลังจากใช เครื องปรับอากาศมาเป นเวลานาน ควรตรวจสภาพและทํา การบํารุงรักษานอกเหน อไปจากการทําความสะอาดตามปกติ สิ งสกปรกหรือฝุ นในตัวเครื องอาจก อให เกิดกลิ นอันไม พึงประสงค ซึ ง มีส วนให เกิดเชื อราได หรืออุดตันทางระบายนํ า และทําให นํ ารั วจาก เ...

Page 14: ...ที มีเอนไซม ต านสาร ก ออาการแพ แบบอิเล กโทรสเตติก ที วางรีโมทคอนโทรล ปุ มควบคุมบานเกล ด แนวนอน หน า 5 ติดตั งที วางรีโมทคอนโทรลใน ตําแหน งที เครื องภายในอาคาร สามารถรับสัญญาณได เมื อไม ใช งานรีโมทคอนโทรล โปรดเก บไว ที แท นเสียบน ส วนแสดงผล 3 กดปุ ม DAY เพื อตั งค าวันที ใช รีโมทคอนโทรลที จัดเตรียมมา กับเครื องเท านั น ห ามใช รีโมทคอนโทรลอันอื น ไฟแสดงการทำงาน ส วนรับสัญญาณรีโมทคอนโทรล สวิตช การทำง...

Page 15: ... โหมดจะเปลี ยนไปตามลําดับดังน 3 กดปุ ม หรือ เพื อตั งอุณหภูมิ เมื อกดปุ มแต ละครั งอุณหภูมิจะเพิ มหรือลดครั งละ 1 C กดปุ ม เพื อหยุดการทํางาน สามารถเลือกการตั งค าแบบเดิมในครั งต อไปโดยการกดปุ ม ฟ งก ชันการเริ มต นการทํางานใหม โดยอัตโนมัติ หากเกิดกระแสไฟขัดข อง หรือไฟหลักถูกตัดในระหว างที เครื องทํางาน ฟ งก ชันการเริ มต น การทํางานใหม โดยอัตโนมัติ จะเริ มทํางานโดยอัตโนมัติตามโหมดเดิมที ได ตั งไว ด...

Page 16: ...ทำความเย นแบบ LONG กดปุ ม เพื อเริ มทํางานในระบบทําความเย นแบบ LONG ความเร วพัดลมเพิ มขึ นและบานเกล ดปรับทิศทางลมขึ น ลงจะปรับไปยังตําแหน ง ของระบบทําความเย นแบบ LONG อากาศครอบคลุมถึงพื นที ระยะไกล กดปุ ม อีกครั งเพื อยกเลิกระบบทําความเย นแบบ LONG ระบบทำความเย นแบบ LONG จะถูกยกเลิกเมื อกดปุ มเป ด ป ดเครื อง ON OFF ปุ มควบคุมบานเกล ดปรับทิศทางลม VANE หรือปุ มระบบความเย นแบบ ECONO COOL กด ในระหว างท...

Page 17: ... สึกเย นสบายได เหมือนเดิม ด วยเหตุน จึงสามารถช วย ประหยัดพลังงานได 1 กดปุ ม หรือ ในขณะที เครื องกำลังทำงานเพื อตั งเวลา การตั งเวลา ON เครื องจะเป ดเมื อถึงเวลาที กำหนด การตั งเวลา OFF เครื องจะป ดเมื อถึงเวลาที กำหนด หรือ กะพริบ ดูให แน ใจว าได ตั งเวลาและวันที ป จจุบันไว ถูกต องแล ว หน า 3 2 กดปุ ม เพิ ม และ ลด เพื อตั งเวลาเป ด ป ด เมื อกดปุ มแต ละครั ง เวลาที ตั งไว จะเพิ มขึ นหรือลดลงครั งละ ...

Page 18: ...ครั งสำหรับแต ละค า สามารถกด เพียงครั งเดียวหลังจากตั ง ค าทั งหมดเสร จแล ว ค าการตั งเวลารายสัปดาห ทั งหมดจะถูกบันทึกไว กด เพื อเข าสู โหมดการตั งเวลารายสัปดาห แล วกด ค างไว 5 วินาที โดยชี รีโมทคอนโทรลไปที เครื องภายในอาคาร เพื อลบค าการตั งเวลารายสัปดาห ทั งหมด 5 กด เพื อเป ดการตั งเวลารายสัปดาห จะสว างขึ น เมื อเป ดการตั งเวลารายสัปดาห วันในรอบสัปดาห ที ตั งค าไว แล วจะสว างขึ น กด อีกครั งเพื ...

Page 19: ...นแพลตินัมมีประสิทธิภาพเหน อกว าสาร คาเตคิน สารไบโอฟลาโวนอยด ที พบในชาเขียว แผ นกรองนาโนแพลตินัมไม เพียงแต ใช สารประกอบน ในการปรับคุณภาพอากาศเท านั น ยังใช กำจัดเชื อแบคทีเรียและไวรัสอีกด วย แผ นกรองอากาศน มีประสิทธิภาพในการกรองอากาศได เกือบถาวรแม ว าจะผ านการล างทำ ความสะอาดด วยน ำแล วก ตาม แผ นกรองฟอกอากาศ แผ นกรองที มีเอนไซม ต านสารก ออาการแพ แบบอิเล กโทรสเตติก ทุกๆ 3 เดือน กำจัดสิ งสกปรกด วยเคร...

Page 20: ...ถูกขั วหรือไม หน า 3 มีการกดปุ มรีโมทคอนโทรลของเครื องใช ไฟฟ า ชนิดอื นหรือไม อาการ รายละเอียดและจุดตรวจสอบ อากาศไม เย น เครื องปรับอากาศทำความเย น ไม เพียงพอ อุณหภูมิที ตั งไว เหมาะสมหรือไม หน า 4 ความเร วใบพัดตั งไว เหมาะสมหรือไม โปรดปรับ ความเร วใบพัดให สูงขึ น หน า 5 แผ นกรองอากาศสกปรกหรือไม หน า 8 ใบพัดหรือตัวเปลี ยนความร อนของเครื องตัวใน สกปรกหรือไม มีสิ งกีดขวางที ช องลมเข าหรือช องลมออกขอ...

Page 21: ...าคาร 550 800 285 880 840 330 น ำหนัก กก เครื องภายในอาคาร 16 เครื องภายนอกอาคาร 36 55 หมายเหตุ 1 เงื อนไขการประเมิน ทำความเย น ภายในอาคาร 27 C DB 19 C WB ภายนอกอาคาร 35 C DB 24 C WB 2 ช วงการทำงานที ได รับการรับประกัน การรักษาสิ งแวดล อม เครื องปรับอากาศ Mitsubishi Electric ถูกออกแบบมาเพื อเป นมิตรกับสิ งแวดล อม ส วนประกอบที ทำจากพลาสติกสามารถนำกลับมาใช ใหม ได เพื อประสิทธิภาพที ดีที สุดและเพื อกา...

Page 22: ...A4 tombo blank indd 1 12 18 2006 9 45 16 AM ...

Page 23: ...A4 tombo blank indd 1 12 18 2006 9 45 16 AM ...

Page 24: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN SG79F400H03 SG79F400H03_Cover indd 2 2009 11 19 17 20 40 ...

Reviews: