background image

En-3

● OPERATING INSTRUCTIONS ●

•   Make sure the polarity of the batteries is correct.

•  

Do not use manganese batteries. The remote controller could malfunction.

•   Do not use rechargeable batteries.

•   Replace all batteries with new ones of the same type.

•  Batteries can be used for approximately 1 year. However, batteries with 

expired shelf lives last shorter.

•  Press RESET gently using a thin instrument.

  If the RESET button is not pressed, the remote controller may not operate 

correctly.

Before operation:

 Insert the power supply plug into the power outlet and/or turn the breaker on.

•  Press CLOCK gently using a thin instrument.

Operation indicator lamp

Remote control receiving section

Emergency 

operation switch 

 Page 4 

Air inlet (back and side)

Refrigerant piping

Drainage hose

Air outlet

Drain outlet

Horizontal vane

Vertical vane

Air outlet

Fan

Air fi lter 

(Nano platinum fi lter)

Air inlet

Heat exchanger

Front panel

Outdoor unit

Installing the remote controller batteries

Setting current time

N

AME OF EACH PART

P

REPARATION BEFORE OPERATION

1.

 Press CLOCK

4.

 Press CLOCK again

2.

 Press either the TIME button or 

the TIMER buttons to set the 

time.

 

Each press increases/decreases 

the time by 1 minute (10 minutes 

when pressed longer)

Indoor unit

Remote controller

Outdoor units may be different in appearance.

1.

 

Remove the front lid

2.

 Insert AAA

alkaline batteries

3.

 Install the front lid

4.

 

Press RESET

Air cleaning fi lter 

(Electrostatic anti-allergy 

enzyme fi lter)

Remote controller holder

Signal transmitting 

section

Distance of signal : 

About 6 m

Beep(s) is (are) heard 

from the indoor unit 

when the signal is 

received.

Operation 

display section

ON/OFF

(operate/stop) button

Temperature 

buttons 

 Page 4 

Operation 

select button 

 Page 4 

ECONO COOL 

button 

 Page 6 

FAN speed control 

button 

 Page 5 

LONG button 

 Page 5 

WIDE VANE 

c

ontrol 

button 

 Page 5 

VANE control button 

 Page 5 

TIME, TIMER set buttons 

 Pages 3, 6 

  Increase time

  Decrease time

CLOCK button 

 Page 3 

RESET button 

 Page 3 

Lid

Slide the lid down to open 

the remote controller. Slide 

it down further to get to the 

weekly timer buttons.

•  Install the remote 

controller holder in a 

place where the sig-

nal can be received 

by the indoor unit.

•  When the remote 

controller is not 

used, place it in this 

holder.

Only use the remote controller provided 

with the unit.

Do not use other remote controllers.

Display section

3.

 Press the DAY button 

to set the day

POWERFUL 

button 

 Page 5 

WEEKLY TIMER

set buttons 

 Page 7 

SG79F400H03_en.indd   3

2009/11/19   17:23:04

Summary of Contents for Mr.SLIM MS-SFF18VC

Page 1: ...TIONERS INDOOR UNIT MS SFF18VC MS SFF24VC English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating in structions before use SG79F400H03_Cover indd 1 2009 11 19 17 20 39 ...

Page 2: ...onditions Do not insert your finger a stick or other objects into the air inlet or outlet This may cause injury since the fan inside rotates at high speeds during operation In case of an abnormal condition such as a burning smell stop the air conditioner and disconnect the power plug or turn the breaker OFF A continued operation in the abnormal state may cause a malfunction fire or electric shock In...

Page 3: ...ning strike The unit may be damaged if lightning strikes After the air conditioner is used for several seasons per form inspection and maintenance in addition to normal cleaning Dirt or dust in the unit may create an unpleasant odor con tribute to growth of fungi such as mold or clog the drain pas sage and cause water to leak from the indoor unit Consult your dealer for inspection and maintenance ...

Page 4: ...h press increases decreases the time by 1 minute 10 minutes when pressed longer Indoor unit Remote controller Outdoor units may be different in appearance 1 Remove the front lid 2 Insert AAA alkaline batteries 3 Install the front lid 4 Press RESET Air cleaning filter Electrostatic anti allergy enzyme filter Remote controller holder Signal transmitting section Distance of signal About 6 m Beep s is a...

Page 5: ...ion mode Each press changes mode in the following order 3 Press or to set the temperature Each press raises or lowers the temperature by 1 C Press to stop the operation The same setting is selected the next time by simply pressing Auto restart function If a power failure occurs or the main power is turned off during operation Auto restart function automatically starts operation in the same mode as...

Page 6: ...automatically moves to the horizontal position after 0 5 to 1 hour to prevent any condensation from dripping Swing The vane moves up and down intermittently AUTO Low Med High AUTO 1 2 3 4 5 SWING SWING LONG OPERATION Press to start LONG operation Fan speed increases and the horizontal vane moves to the position for LONG mode Air reaches to longer distance Press again to cancel LONG operation LONG ...

Page 7: ... cooling operation with keeping comfort As a result energy can be saved 1 Press or during operation to set the timer ON timer The unit turns ON at the set time OFF timer The unit turns OFF at the set time or blinks Make sure that the current time and day are set correctly Page 3 2 Press Increase and Decrease to set the time of timer Each press increases or decreases the set time by 10 minutes Set ...

Page 8: ...eekly timer setting mode and press and hold for 5 seconds to erase all weekly timer settings Point the remote controller toward the indoor unit 5 Press to turn the weekly timer ON lights When the weekly timer is ON the day of the week whose timer setting is complete will light Press again to turn the weekly timer OFF goes out Note The saved settings will not be cleared when the weekly timer is tur...

Page 9: ...to the filter material which results in pro viding semi permanent antibacterial and deodorizing characteristics for the filter Nano platinum surpasses the catechin a bioflavonoid that is found in green tea in performance Nano platinum filter uses this compound not only to improve air quality but also to eliminate bacteria and viruses This air filter has a semi permanent lasting effect even after washin...

Page 10: ...ontroller of other electric appliances being pressed Symptom Explanation Check points Does not cool The room cannot be cooled sufficiently Is the temperature setting appropriate Page 4 Is the fan setting appropriate Please change fan speed to higher setting Page 5 Are the filters clean Page 8 Is the fan or heat exchanger of the indoor unit clean Are there any obstacles blocking the air inlet or outl...

Page 11: ...es the inside of the unit Moisture in the air conditioner contributes to growth of fungi such as mold 2 Press to stop the operation 3 Turn off the breaker and or disconnect the power sup ply plug 4 Remove all batteries from the remote controller When using the air conditioner again 1 Clean the air filter Page 8 2 Check that the air inlet and outlet of the indoor and outdoor units are not blocked 3 ...

Page 12: ...นอยู กับสภาพการใช งานนั นๆ อย าสอดนิ ว กิ งไม หรือวัตถุอื นๆ เข าไปในช องลมเข าหรือช องลมออก เน องจากใบพัดหมุนด วยความเร วสูงในขณะที เครื องทํางาน อาจ เป นสาเหตุให เกิดอาการบาดเจ บได เมื อเกิดสิ งผิดปกติ เช น กลิ นเหม นไหม เป นต น ให ป ดเครื องปรับ อากาศและถอดปลั กไฟ หรือสับเบรกเกอร ลง หากเครื องปรับอากาศยังถูกใช งานต อไปทั งๆ ที อยู ในสภาพผิดปกติ อาจเป นสาเหตุให เครื องทํางานผิดพลาด ไฟไหม หรือไฟด...

Page 13: ...ากาศที ไม ดีเพียงพออาจทําให เกิดภาวะขาดออกซิเจนได สับเบรกเกอร ลง หากท านได ยินเสียงฟ าร อง และมีความเป นไปได ที จะ เกิดฟ าผ า เครื องอาจชํารุด หากโดนฟ าผ า หลังจากใช เครื องปรับอากาศมาเป นเวลานาน ควรตรวจสภาพและทํา การบํารุงรักษานอกเหน อไปจากการทําความสะอาดตามปกติ สิ งสกปรกหรือฝุ นในตัวเครื องอาจก อให เกิดกลิ นอันไม พึงประสงค ซึ ง มีส วนให เกิดเชื อราได หรืออุดตันทางระบายนํ า และทําให นํ ารั วจาก เ...

Page 14: ...ที มีเอนไซม ต านสาร ก ออาการแพ แบบอิเล กโทรสเตติก ที วางรีโมทคอนโทรล ปุ มควบคุมบานเกล ด แนวนอน หน า 5 ติดตั งที วางรีโมทคอนโทรลใน ตําแหน งที เครื องภายในอาคาร สามารถรับสัญญาณได เมื อไม ใช งานรีโมทคอนโทรล โปรดเก บไว ที แท นเสียบน ส วนแสดงผล 3 กดปุ ม DAY เพื อตั งค าวันที ใช รีโมทคอนโทรลที จัดเตรียมมา กับเครื องเท านั น ห ามใช รีโมทคอนโทรลอันอื น ไฟแสดงการทำงาน ส วนรับสัญญาณรีโมทคอนโทรล สวิตช การทำง...

Page 15: ... โหมดจะเปลี ยนไปตามลําดับดังน 3 กดปุ ม หรือ เพื อตั งอุณหภูมิ เมื อกดปุ มแต ละครั งอุณหภูมิจะเพิ มหรือลดครั งละ 1 C กดปุ ม เพื อหยุดการทํางาน สามารถเลือกการตั งค าแบบเดิมในครั งต อไปโดยการกดปุ ม ฟ งก ชันการเริ มต นการทํางานใหม โดยอัตโนมัติ หากเกิดกระแสไฟขัดข อง หรือไฟหลักถูกตัดในระหว างที เครื องทํางาน ฟ งก ชันการเริ มต น การทํางานใหม โดยอัตโนมัติ จะเริ มทํางานโดยอัตโนมัติตามโหมดเดิมที ได ตั งไว ด...

Page 16: ...ทำความเย นแบบ LONG กดปุ ม เพื อเริ มทํางานในระบบทําความเย นแบบ LONG ความเร วพัดลมเพิ มขึ นและบานเกล ดปรับทิศทางลมขึ น ลงจะปรับไปยังตําแหน ง ของระบบทําความเย นแบบ LONG อากาศครอบคลุมถึงพื นที ระยะไกล กดปุ ม อีกครั งเพื อยกเลิกระบบทําความเย นแบบ LONG ระบบทำความเย นแบบ LONG จะถูกยกเลิกเมื อกดปุ มเป ด ป ดเครื อง ON OFF ปุ มควบคุมบานเกล ดปรับทิศทางลม VANE หรือปุ มระบบความเย นแบบ ECONO COOL กด ในระหว างท...

Page 17: ... สึกเย นสบายได เหมือนเดิม ด วยเหตุน จึงสามารถช วย ประหยัดพลังงานได 1 กดปุ ม หรือ ในขณะที เครื องกำลังทำงานเพื อตั งเวลา การตั งเวลา ON เครื องจะเป ดเมื อถึงเวลาที กำหนด การตั งเวลา OFF เครื องจะป ดเมื อถึงเวลาที กำหนด หรือ กะพริบ ดูให แน ใจว าได ตั งเวลาและวันที ป จจุบันไว ถูกต องแล ว หน า 3 2 กดปุ ม เพิ ม และ ลด เพื อตั งเวลาเป ด ป ด เมื อกดปุ มแต ละครั ง เวลาที ตั งไว จะเพิ มขึ นหรือลดลงครั งละ ...

Page 18: ...ครั งสำหรับแต ละค า สามารถกด เพียงครั งเดียวหลังจากตั ง ค าทั งหมดเสร จแล ว ค าการตั งเวลารายสัปดาห ทั งหมดจะถูกบันทึกไว กด เพื อเข าสู โหมดการตั งเวลารายสัปดาห แล วกด ค างไว 5 วินาที โดยชี รีโมทคอนโทรลไปที เครื องภายในอาคาร เพื อลบค าการตั งเวลารายสัปดาห ทั งหมด 5 กด เพื อเป ดการตั งเวลารายสัปดาห จะสว างขึ น เมื อเป ดการตั งเวลารายสัปดาห วันในรอบสัปดาห ที ตั งค าไว แล วจะสว างขึ น กด อีกครั งเพื ...

Page 19: ...นแพลตินัมมีประสิทธิภาพเหน อกว าสาร คาเตคิน สารไบโอฟลาโวนอยด ที พบในชาเขียว แผ นกรองนาโนแพลตินัมไม เพียงแต ใช สารประกอบน ในการปรับคุณภาพอากาศเท านั น ยังใช กำจัดเชื อแบคทีเรียและไวรัสอีกด วย แผ นกรองอากาศน มีประสิทธิภาพในการกรองอากาศได เกือบถาวรแม ว าจะผ านการล างทำ ความสะอาดด วยน ำแล วก ตาม แผ นกรองฟอกอากาศ แผ นกรองที มีเอนไซม ต านสารก ออาการแพ แบบอิเล กโทรสเตติก ทุกๆ 3 เดือน กำจัดสิ งสกปรกด วยเคร...

Page 20: ...ถูกขั วหรือไม หน า 3 มีการกดปุ มรีโมทคอนโทรลของเครื องใช ไฟฟ า ชนิดอื นหรือไม อาการ รายละเอียดและจุดตรวจสอบ อากาศไม เย น เครื องปรับอากาศทำความเย น ไม เพียงพอ อุณหภูมิที ตั งไว เหมาะสมหรือไม หน า 4 ความเร วใบพัดตั งไว เหมาะสมหรือไม โปรดปรับ ความเร วใบพัดให สูงขึ น หน า 5 แผ นกรองอากาศสกปรกหรือไม หน า 8 ใบพัดหรือตัวเปลี ยนความร อนของเครื องตัวใน สกปรกหรือไม มีสิ งกีดขวางที ช องลมเข าหรือช องลมออกขอ...

Page 21: ...าคาร 550 800 285 880 840 330 น ำหนัก กก เครื องภายในอาคาร 16 เครื องภายนอกอาคาร 36 55 หมายเหตุ 1 เงื อนไขการประเมิน ทำความเย น ภายในอาคาร 27 C DB 19 C WB ภายนอกอาคาร 35 C DB 24 C WB 2 ช วงการทำงานที ได รับการรับประกัน การรักษาสิ งแวดล อม เครื องปรับอากาศ Mitsubishi Electric ถูกออกแบบมาเพื อเป นมิตรกับสิ งแวดล อม ส วนประกอบที ทำจากพลาสติกสามารถนำกลับมาใช ใหม ได เพื อประสิทธิภาพที ดีที สุดและเพื อกา...

Page 22: ...A4 tombo blank indd 1 12 18 2006 9 45 16 AM ...

Page 23: ...A4 tombo blank indd 1 12 18 2006 9 45 16 AM ...

Page 24: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN SG79F400H03 SG79F400H03_Cover indd 2 2009 11 19 17 20 40 ...

Reviews: