5
SPECIFICATION
3
Notes : Test conditions are based on ARI 210/240
❈
1 :
Rating conditions (cooling) — Indoor : 80˚FDB, 67˚FWB, Outdoor : 95˚FDB, (75˚FWB) Rated frequency : 60Hz
Operating Range
Cooling
Maximum
Minimum
Indoor intake air temperature
95˚FDB, 71˚FWB
67˚FDB, 57˚FWB
Outdoor intake air temperature
115˚FDB
67˚FDB
Item
Model
MS-A12WA
Indoor unit model
External finish
Power supply
Max. fuse size (time delay)/ Disconnect switch
Min. circuit ampacity
Fan motor
Airflow Low—Med.—High
Moisture removal
Sound level Low-Med.-High
Cond. drain connection O.D.
Dimensions
Weight
Remote controller
Control voltage (by built-in transformer)
V, phase, Hz
A
A
F.L.A
CFM
pt./h
dB(A)
in.
in.
in.
in.
Ib.
MS-A12WA
1.2
0.95
406(363)-286(254)-222(198)
3.2
33-38-45
23
MS-A09WA
1.2
0.95
335(300)-261(233)-183(162)
2.7
26-32-40
23
MS-A09WA
COOL Dry (Wet)
W
D
H
-
White
115, 1, 60
15
5/8
30-11/16
8-1/4
11-3/4
Wireless type
115V AC
OB448A-1.qxp 07.5.14 4:20 PM Page 5