15
8-5. Trouble criterion of main parts
MS-A09WA
MS-A12WA
Part name
Figure
Check method and criterion
Indoor fan motor(MF)
Measure the resistance with a tester. (Part temperature 50˚F ~ 86˚F)
Refer to 8-7. "Test point diagram and voltage", the chart of thermistor.
Room temperature
thermistor(RT11)
Indoor coil thermistor
(RT12)
Horizontal vane
motor(MV)
Normal
BRN-other one
Measure the resistance between the terminals with a tester.
(Part temperature 50
°
F ~ 86
°
F)
235
"
~ 255
"
Color of the lead wire
Check 8-6.
A
.
RED
YLW
BRN
ORN
GRN
ROTOR