8
SPECIFICATION
4
Specifications and rated conditions of main electric parts
Model
Item
MLZ-KP25VF MLZ-KP35VF MLZ-KP50VF
Fuse (F11)
T3.15AL250V
Horizontal vane motor
(MV1)
12 V DC
Vertical vane motor
(MV2)
12 V DC
Varistor
(NR11)
470 V
DRAIN PUMP
(DP)
230 V 6.4 W
FLOAT SENSOR
(FS)
5 V DC
Indoor model
MLZ-KP25VF
MLZ-KP35VF
MLZ-KP50VF
Function
Cooling
Heating
Cooling
Heating
Cooling
Heating
Power supply
Single phase
230V, 50Hz
Single phase
230V, 50Hz
Single phase
230V, 50Hz
Capacity Air fl ow (High/Med./Low/SLow) m
3
/h 528/480/432/360 552/492/420/360 564/504/438/360 594/528/462/360 684/588/498/360 708/618/528/360
Electrical
data
Running current 1
A
0.4
0.4
0.4
Power input 1
W
40
40
40
Auxiliary heater
A(kW)
-
-
-
Power factor 1
%
58
58
58
Fan motor current 1
A
0.3
0.3
0.3
Fan
motor
Model
RC0J30-CZ
RC0J30-CZ
RC0J30-CZ
Dimensions W x H x D
mm
1102 x 185 x 360
1102 x 185 x 360
1102 x 185 x 360
Weight
kg
15.5
15.5
15.5
Special
remarks
Air direction
5
5
5
Sound level (High/Med./Low/SLow) dB(A)
38/34/31/27
37/34/29/26
40/36/32/27
40/36/32/26
47/41/36/29
48/42/37/26
Fan speed (High/Med./Low/SLow)
rpm
1110/1020/930/800
1150/1040/910/800 1170/1060/940/800 1220/1100/990/800 1380/1220/1060/800 1420/1270/1110/800
Fan speed regulator
4
4
4
Remote controller model
SG175
NOTE: Test conditions are based on ISO 5151.
Cooling: Indoor
Dry-bulb temperature 27°C Wet-bulb temperature 19°C
Outdoor Dry-bulb temperature 35°C
Heating: Indoor
Dry-bulb temperature 20°C
Outdoor Dry-bulb temperature 7°C Wet-bulb temperature 6°C
Refrigerant piping length (one way): 5m
1 Measured under rated operating frequency. (Only indoor unit)
OBH801