background image

En-1

1-1. tHE FoLLoWING sHouLD ALWAYs BE oBsERVED FoR sAFEtY

•  Be sure to read “THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY” before installing the air conditioner.

•  Be sure to observe the warnings and cautions specified here as they include important items related to safety.

•  After reading this manual, be sure to keep it together with the OPERATING INSTRUCTIONS for future reference.

•  Please report to your supply authority or obtain their consent before connecting this equipment to the power supply system.

Required tools for Installation

  Do not install the unit by yourself (user).

  Incomplete installation could cause fire or electric 

shock, injury due to the unit falling, or leakage 

of  water.  Consult  the  dealer  from  whom  you 

purchased the unit or a qualified installer.

  Perform the installation securely referring 

to the installation manual.

  Incomplete installation could cause fire or electric 

shock, injury due to the unit falling, or leakage of 

water.

  When installing the unit, use appropriate 

protective equipment and tools for safety.

  Failure to do so could cause injury.

  Install the unit securely in a place which 

can bear the weight of the unit.

  If the installation location cannot bear the weight 

of the unit, the unit could fall causing injury.

■ 

Electrical work should be performed by a 

qualified, experienced electrician, accord

-

ing to the installation manual. Be sure to 

use an exclusive circuit. Do not connect 

other electrical appliances to the circuit.

  If the capacity of the power circuit is insufficient 

or  there  is  incomplete  electrical  work,  it  could 

result in a fire or an electric shock.

  Ground the unit correctly.

  Do not connect the ground to a gas pipe, water 

pipe, lightning rod or telephone ground. Defective 

grounding could cause electric shock.

■ 

Do not damage the wires by applying 

excessive pressure with parts or screws.

  Damaged wires could cause fire or electric shock.

■ 

Be sure to cut off the main power in case of 

setting up the indoor P.C. board or wiring 

works.

  Failure to do so could cause electric shock.

  Use the specified wires to connect the 

indoor and outdoor units securely and 

attach the wires firmly to the terminal block 

connecting sections so the stress of the 

wires is not applied to the sections. Do not 

extend the wires, or use intermediate con

-

nection.

  Incomplete connecting and securing could cause 

fire.

■ 

Do not install the unit in a place where 

inflammable gas may leak.

  If gas leaks and accumulates in the area around 

the unit, it could cause an explosion.

  Do not use intermediate connection of the 

power cord or the extension cord and do 

not connect many devices to one AC outlet.

  It could cause a fire or an electric shock due to 

defective contact, defective insulation, exceeding 

the permissible current, etc.

■ 

Be sure to use the parts provided or speci-

fied parts for the installation work.

  The use of defective parts could cause an injury 

or  leakage  of  water  due  to  a  fire,  an  electric 

shock, the unit falling, etc.

■ 

When plugging the power supply plug into 

the outlet, make sure that there is no dust, 

clogging, or loose parts in both the outlet 

and the plug. Make sure that the power 

supply plug is pushed completely into the 

outlet.

  If there is dust, clogging, or loose parts on the 

power supply plug or the outlet, it could cause 

electric shock or fire. If loose parts are found on 

the power supply plug, replace it.

■ 

Attach the electrical cover to the indoor 

unit and the service panel to the outdoor 

unit securely.

  If the electrical cover of the indoor unit and/or the 

service panel of the outdoor unit are not attached 

securely, it could result in a fire or an electric 

shock due to dust, water, etc.

■ 

When installing, relocating, or servicing 

the unit, make sure that no substance 

other than the specified refrigerant (R410A) 

enters the refrigerant circuit.

  Any presence of foreign substance such as air 

can cause abnormal pressure rise and may result 

in explosion or injury. The use of any refrigerant 

other than that specified for the system will cause 

mechanical failure, system malfunction, or unit 

breakdown. In the worst case, this could lead to 

a serious impediment to securing product safety.

■ 

Do not discharge the refrigerant into the 

atmosphere. Check that the refrigerant gas 

does not leak after installation has been 

completed. If refrigerant leaks during instal-

lation, ventilate the room.

  If refrigerant comes in contact with a fire, harmful 

gas could be generated. 

  If refrigerant gas leaks indoors, and comes into 

contact  with  the  flame  of  a  fan  heater,  space 

heater, stove, etc., harmful gases will be gener

-

ated.

■ 

use appropriate tools and piping materials 

for installation.

  The pressure of R410A is 1.6 times more than 

R22. Not using appropriate tools or materials and 

incomplete installation could cause the pipes to 

burst or injury. 

■ 

When pumping down the refrigerant, stop 

the compressor before disconnecting the 

refrigerant pipes.

  If the refrigerant pipes are disconnected while 

the compressor is running and the stop valve is 

open, air could be drawn in and the pressure in 

the refrigeration cycle could become abnormally 

high. This could cause the pipes to burst or injury.

■ 

When installing the unit, securely connect 

the refrigerant pipes before starting the 

compressor.

  If the compressor is started before the refrigerant 

pipes are connected and when the stop valve is 

open, air could be drawn in and the pressure in 

the refrigeration cycle could become abnormally 

high. This could cause the pipes to burst or injury.

■ 

Fasten a flare nut with a torque wrench as 

specified in this manual.

  If fastened too tight, a flare nut may break after 

a long period and cause refrigerant leakage.

■ 

the unit shall be installed in accordance 

with national wiring regulations.

■ 

Do not use means to accelerate the defrost-

ing process or to clean, other than those 

recommended by the manufacturer.

■ 

the appliance shall be stored in a room 

without continuously operating ignition 

sources (for example: open flames, an 

operating gas appliance or an operating 

electric heater).

■ 

Do not pierce or burn.

■ 

Be aware that refrigerants may not contain 

an odour.

■ 

Pipe-work shall be protected from physical 

damage.

■ 

the installation of pipe-work shall be kept 

to a minimum.

■ 

Keep any required ventilation openings 

clear of obstruction.

■ 

Keep gas-burning appliances, electric 

heaters, and other fire sources (ignition 

sources) away from the location where in-

stallation, repair, and other air conditioner 

work will be performed.

 WARNING

(Could lead to death, serious injury, etc.)

 ENGLISH

This installation manual describes only for the 

indoor unit. Refer to the MXZ type manual for 

outdoor unit set up.

CoNtENts

1.  BEFORE INSTALLATION ............................ 1

2.  INDOOR UNIT INSTALLATION ................... 4

3.  FLARING WORK AND PIPE 

 

CONNECTION ............................................

8

4.  TEST RUN................................................. 10

5.  GRILLE (OPTION) INSTALLATION .......... 10

6.  PUMPING DOWN ..................................... 11

7.  CONNECTING AN INTERFACE (OPTION) 

TO THE AIR CONDITIONER .................... 11

Phillips screwdriver

Level

Scale

Utility knife or scissors

2-15/16 in. (75 mm) hole saw

Torque wrench

Wrench (or spanner)

Flare tool for R410A

Gauge manifold for R410A

Vacuum pump for R410A

Charge hose for R410A

Pipe cutter with reamer

Water bottle

 

0.9 to 1.0 L water

1.  BEFoRE INstALLAtIoN

 CAUTION

(Could lead to serious injury in particular environments when operated incorrectly.)

  Depending on the installation area, install a 

Ground Fault Interrupt (GFI) circuit breaker.

  If the Ground Fault Interrupt (GFI) circuit breaker 

is not installed, an electric shock could occur.

  Perform the drainage/piping work securely 

according to the installation manual.

  If  there  is  defect  in  the  drainage/piping  work, 

water  could  drip  from  the  unit,  and  damage 

household items.

  Do not touch the air inlet or the aluminum 

fins of the outdoor unit.

  This could cause injury. 

  Do not install the outdoor unit where small 

animals may live.

  If small animals enter the unit and damage its 

electrical  parts,  it  could  cause  a  malfunction, 

smoke emission, or fire. Keep the area around 

the unit clean. 

RG79Y948H01_en.indd   1

2018/01/23   11:41:53

Summary of Contents for MLZ-KP09NA

Page 1: ...to the installation manual of outdoor unit NotICE D INstALLAtIoN POUR L INSTALLATEUR Cette notice ne décrit que l installation de l unité interne Pour l installation de l unité externe se reporter à la notice d installation de l appareil MANuAL DE INstALACIÓN PARA EL INSTALADOR En este manual sólo se describe la instalación de la unidad interior Para instalar la unidad exterior consulte el manual ...

Page 2: ...can cause abnormal pressure rise and may result in explosion or injury The use of any refrigerant other than that specified for the system will cause mechanical failure system malfunction or unit breakdown In the worst case this could lead to a serious impediment to securing product safety Do not discharge the refrigerant into the atmosphere Check that the refrigerant gas does not leak after insta...

Page 3: ... Salty places such as the seaside Where sulfide gas is generated such as hot spring sewage waste water Where there is high frequency or wireless equipment Where there is emission of high levels of VOCs including phthalate compounds formaldehyde etc which may cause chemical cracking The appliance shall be stored so as to prevent mechanical damage from occurring Electrical specifications INDOOR UNIT...

Page 4: ...e putty cover 1 M Pipe fixing band 2 to 7 N Fixing screw for M 2 to 7 P Piping tape 1 to 5 Q Protective tape 1 Note Place indoor outdoor unit connecting wire D at least 3 ft 1 m away from the TV antenna wire service space The dimensions of ceiling opening can be regulated within the range shown in following diagram so center the main unit against the open ing of ceiling ensuring that the respectiv...

Page 5: ...eams single storied houses or second floor beams two story houses as reinforcing members Wooden beams for suspending air conditioners must be sturdy and their sides must be at least 2 3 8 in 60 mm long if the beams are separated by not more than 35 7 16 in 900 mm and their sides must be at least 3 9 16 in 90 mm long if the beams are separated by as much as 6 ft 1800 mm Use channel duct and other p...

Page 6: ...l may not open close 3 If the long opening in the bracket and opening in the ceiling do not align adjust them until they do 4 Check that the four places for securing the grille are all level using a spirit level 5 Tighten all the nuts 2 3 DRAIN PIPING Use drain pipe B for drain piping Be sure to connect the piping joints using adhesive of polyvinyl chloride family to prevent leakage Before drain p...

Page 7: ...ily before installing the hose band Drain hose Drain pipe B Do not make drain piping as shown Pipe elbow Hose band Apply insulating material J until drain piping connecting part as shown in the upper right illustration Drain piping should form a downward slope 1 100 or more to the outdoor drain exit Do not form trap or raise the pipe Do not arrange the pipe horizontally for more than 65 ft 20 m Wh...

Page 8: ...nut The indoor outdoor unit connecting wire D appearing from the inside of conduit pipe should be less than 7 8 in 23 mm Fig 1 4 Process the end of ground wire Fig 2 Connect it to the ground terminal of the electrical parts box 5 Process the end of indoor outdoor unit connecting wire D Fig 2 Attach it to the terminal block Be careful not to make mis wiring Attach the wire to the terminal block sec...

Page 9: ...n ø48 mm liquid pipe ø2 in ø51 mm gas pipe for indoor connect ing pipe remove plate and turn it over so that the concave part faces upward When the ceiling is above 8 ft 2 4 m and 9 ft 2 7 m or below Move the slide switch SW3 to the right to increase airflow volume When the ceiling is above 9 ft 2 7 m airflow volume may be insufficient even with the slide switch SW3 set to increase airflow 1 Make ...

Page 10: ... Die Copper pipe Clutch type Flaring tool Wing nut type 3 4 INSTALLING THE PIPE COVER Make sure to install the pipe cover Incorrect installation results in water leakage No insulation is needed on the pipe connecting part of the indoor side for this unit The pipe cover gathers the water condensed around the pipe connecting part 1 Install the pipe band removed in 3 1 to secure the connecting pipes ...

Page 11: ...ergency operation switch for 5 seconds until a beep is heard to start the operation of only the drain pump The two operation monitor lamps start blinking 2 Stop the drain pump test run Press the emergency operation switch again to stop the operation of the drain pump Even if you do not stop the drain pump it will stop automatically after 15 minutes The operation monitor lamps turn off 4 3 AUTO RES...

Page 12: ...le If the grille has been already installed 3 Remove the electrical cover 1 2 Refer to 2 4 CONNECTING WIRES FOR INDOOR UNIT 4 Slide out the indoor control board and connect the connecting cable to CN105 and or CN24 on the indoor control board 5 Remove the screw shown in the photo blow Route the connecting cable according to the photo below Fix the mounting cord clamp medium which has attached to t...

Page 13: ...agua etc Al instalar reubicar o reparar la unidad ase gúrese de que en el circuito de refrigeración no entra ninguna otra sustancia que no sea el refrigerante especificado R410A La presencia de cualquier otra sustancia extra ña como aire por ejemplo puede provocar una elevación anómala de la presión una explosión o daños corporales El uso de un refrigerante distinto al especificado por el sistema oc...

Page 14: ...as sulfúrico como en zonas de baños termales alcanta rillas o aguas residuales Donde haya algún equipo inalámbrico o de alta frecuencia Donde haya elevadas emisiones de COV incluidos compuestos de ftalato aldehído fórmico etc que puedan causar craqueos El aparato debe almacenarse para evitar que se produzcan averías mecánicas Electrical specifications UNIDAD INTERIOR Alimentación V FASE Hz 208 230 ...

Page 15: ...ervicio Las dimensiones de la abertura en el techo pueden regularse dentro del rango que aparece en el siguiente diagrama así pues centre la unidad principal en la abertura asegurándose de que los respectivos lados opuestos queden a la misma distancia del borde de la abertura Después de la prueba de fugas aplique material aislante de modo que no queden huecos Cuando los tubos deban instalarse en u...

Page 16: ... plantas casa de dos plantas como refuerzos Los tirantes de madera para acondicionadores de aire suspendidos de ben ser resistentes y sus lados deben tener al menos 2 3 8 pulg 60 mm de longitud si se separan menos de 35 7 16 pulg 900 mm y al menos 3 9 16 pulg 90 mm de longitud si se separan hasta 6 pies 1800 mm Utilice canales conductos y otras piezas suministradas localmente para suspender la uni...

Page 17: ...án ali neadas ajústelas hasta que lo hagan 4 Mediante un nivel de burbuja compruebe que las cuatro posiciones para asentar la rejilla estén niveladas 5 Apriete todas las tuercas 2 3 TUBERÍA DE DRENAJE Utilice la tubería de drenaje B para el drenaje Asegúrese de conec tar las uniones de tuberías utilizando adhesivo de la familia del cloru ro de polivinilo para evitar fugas Antes de tender las tuber...

Page 18: ... de modo que el grupo quede unos 3 15 16 pulg 100 mm por debajo de la salida de drena je de la unidad tal y como aparece en la figura Utilice un tubería de drenaje diám ext 1 1 2 pulg 38 mm para el tendido agrupado y realice el tendido de manera que forme una inclinación descendente de aprox 1 100 o más No coloque la tubería de drenaje directamente en un lugar donde se forme gases de amoniaco o gas...

Page 19: ...rior de la tubería de conducción debe ser menor de 7 8 pulg 23 mm Fig 1 4 Procese el extremo del cable de tierra Fig 2 Conéctelo al terminal de tierra de la caja de piezas eléctricas 5 Procese el extremo del cable de conexión de la unidad interior exterior D Fig 2 Conéctelo al panel de terminales Procure no equivocarse al hacer las conexiones Fije con firmeza el cable al panel de terminales de modo...

Page 20: ... de 9 pies 2 7 m Mueva el interruptor deslizante SW3 hacia la derecha para aumentar el volumen de flujo de aire Si el techo supera los 9 pies 2 7 m de altura el volumen de flujo de aire puede resultar insuficiente aunque haya colocado el interruptor deslizante SW3 en la posición de flujo aumentado 1 Asegúrese de que el disyuntor del acondicionador de aire está DES CONECTADO 2 Retire las cubiertas eléc...

Page 21: ...rca abocardada Pieza de fijación Tubería de cobre Tipo manguito de embrague Abocardador Tipo tuerca de aletas 3 4 INSTALACIÓN DE LA CUBIERTA DE TUBERÍA Asegúrese de instalar la cubierta de tubería Una instalación incorrecta puede causar fugas de agua No es necesario ningún aislante en la pieza de conexión de la tubería en la parte interior para esta unidad La cubierta de tubería recoge el agua cond...

Page 22: ...tomáticamente al volver a conectar la alimentación Para el usuario Después de instalar la unidad asegúrese de que explica al usua rio los detalles de la función de puesta en marcha automática Si la función de puesta en marcha automática no es necesaria puede desactivarse Consulte al representante técnico para des activar esta función Si desea más detalles consulte las instruc ciones de funcionamie...

Page 23: ...a ampliación Pase el cable de conexión como se muestra en fotografía siguiente Fije la abrazadera del cable de montaje media acoplado al cable de conexión con el tornillo 6 Vuelva a instalar la tarjeta de control interior y la cubierta de la instalación eléctrica 1 2 7 Vuelva a instalar la rejilla Abrazadera del cable de montaje media Brida 3 15 16 pulg 100 mm Pieza con revestimiento aislante Part...

Page 24: ...e du boîtier élec trique de l unité interne et le panneau de service de l unité externe Si le couvercle du boîtier électrique de l unité interne et ou le panneau de service de l unité externe sont mal fixés ils risquent de provoquer un incendie ou une électrocution en raison de la poussière de l eau etc présentes dans le circuit Lors de l installation du déplacement ou de l entretien de l appareil ...

Page 25: ...teur sur l appareil concerné Emplacement aussi éloigné que possible des lampes fluorescentes et à lumière incandescente Ceci afin que le climatiseur puisse capter les signaux infrarouges envoyés par la télécommande La chaleur générée par ces lampes peut entraîner une déformation ou les ultraviolets peuvent entraîner une détérioration Emplacement permettant de retirer et de changer facilement le filt...

Page 26: ...e de fixation de tuyau 2 à 7 N Vis de fixation pour M 2 à 7 P Ruban adhésif de tuyauterie 1 à 5 Q Ruban de protection 1 Remarque Placer le câble de connexion de l unité interne externe D à 3 ft 1 m minimum du câble de l antenne TV Espace d entretien Les dimensions de l ouverture au plafond peuvent être comprises dans la plage figurant sur le schéma suivant Par conséquent cen trer l unité principale d...

Page 27: ...mme éléments de renfort Les poutres en bois utilisées pour suspendre le climatiseur doivent être robustes et mesurer au moins 2 3 8 in 60 mm de côté si elles sont installées à moins de 35 7 16 in 900 mm l une de l autre Si les poutres se trouvent à une distance de 6 ft 1800 mm l une de l autre elles doivent mesurer au moins 3 9 16 in 90 mm de côté Utiliser un profilé en U un conduit ainsi que d aut...

Page 28: ...ur du support et l ouverture du plafond ne sont pas alignées les faire correspondre 4 A l aide d un niveau à bulle vérifiez que les quatre points de fixation de la grille sont tous de niveau 5 Serrer tous les écrous 2 3 VIDANGE Utiliser un tuyau de vidange B Veiller à connecter les raccords de tuyauterie à l aide d adhésif de la famille des PVC pour éviter les fuites Avant de procéder à la vidange r...

Page 29: ...0 mm en des sous de la sortie de la vidange de l unité comme sur l illustration Utiliser un tuyau de vidange diam ext 1 1 2 in 38 mm pour le regroupement et former une pente négative d environ 1 100 Ne pas placer le tuyau de vidange directement dans un endroit où de l ammoniac ou du gaz sulfurique se forme comme dans un réservoir d eaux usées ou une fosse septique Insérer complètement le tuyau de ...

Page 30: ...nexion D de l unité interne externe qui apparaît à l intérieur du tube de canalisation doit être inférieur à 7 8 in 23 mm Fig 1 4 Préparez l extrémité du câble de terre Fig 2 Branchez la à la borne de mise à la terre du boîtier électrique 5 Préparez l extrémité du câble de connexion de l unité interne externe D Fig 2 Branchez la au bloc de raccordement Veillez à ne pas effectuer d erreur de branch...

Page 31: ...r du plafond est comprise entre 8 ft 2 4 m et 9 ft 2 7 m Déplacer l interrupteur à glissière SW3 vers la droite pour augmenter le volume de circulation d air Lorsque la hauteur du plafond dépasse 9 ft 2 7 m le volume de cir culation d air risque d être insuffisant même si l interrupteur à glissière SW3 est réglé sur increase airflow 1 Veiller à ce que le disjoncteur du climatiseur soit éteint 2 Ret...

Page 32: ...ans rayures Fig 5 Fig 6 A Ecrou évasé Filière Tuyau en cuivre Modèle à manivelle Outil d évasement Modèle avec écrous à ailette 3 4 INSTALLATION DU CACHE TUYAUX Veiller à installer le cache tuyaux Une installation incorrecte pourrait entraîner des fuites d eau Aucune isolation n est requise pour le raccordement de la face interne de l unité Le cache tuyaux amasse l eau condensée autour du raccorde...

Page 33: ...avant de couper l alimentation Sinon l unité se remettra automatiquement en marche lorsque l alimentation est rétablie A l attention de l utilisateur Après installation de l unité veillez à expliquer à l utilisateur la fonction de redémarrage automatique Si la fonction de redémarrage automatique n est pas indispensa ble elle peut être désactivée Adressez vous au responsable de l entretien pour dés...

Page 34: ...24 du panneau de com mande de l unité interne 5 Retirez la vis illustrée sur l image ci dessous Installez le câble de connexion comme illustré sur l image ci dessous Fixez le collier du câble de montage moyen qui a été attaché au câble de connexion avec la vis 6 Réinstallez le tableau de commandes intérieur et le couvercle du boîtier électrique 1 2 7 Réinstallez la grille Collier du câble de monta...

Page 35: ......

Page 36: ...RG79Y948H01 HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN This product is designed and intended for use in the residential commercial and light industrial environment ...

Reviews: