32
Operation Checks
①
When the side of the move sensor assembly is
held and rotated left and right about 60 degrees
(a total of 120 degrees), the fan must move
smoothly in sync.
②
When louvre N is held and rotated by hand, it
must operate smoothly with no unusual noises.
③
At the upward position (until the top casing is
slanted), the louvre CY-N must open.
④
The louvre CY-N top edge must be at the parting
position at the stop position.
⑤
The louvre CY-2 front edge must be at the
difference position at the stop position.
⑥
The louvre CY-3 front edge must be at the
stopper position at the stop position.
⑦
Louvre CY-1, CY-2, and CY-3 must have no
gaps.
<Precautions for Assembly>
• When the move sensor assembly side is held and rotated left and right 60° (a total of 120°), adjust
the length of the sensor lead wires so that they do not become taut, and secure with tape.
①
Left and right 60°
②
Rotate up and down
Gear holder
⑤
Difference position
⑥
Stopper position
④
Parting position
Louvre CY-N
Give them some slack
Filament tape
MOVE EYE
Rotate left
and right 60°
Summary of Contents for MJ-E14EG-S1-IT
Page 2: ...2 1 Precautions 2 Note This page is extracted from the instruction manual ...
Page 3: ...3 3 Note This page is extracted from the instruction manual ...
Page 4: ...4 2 Names and Functions of Parts Note This page is extracted from the instruction manual ...
Page 8: ...8 7 Technical Points Note This page is extracted from the instruction manual ...
Page 18: ...18 Note This page is extracted from the instruction manual 10 Troubleshooting ...
Page 19: ...19 Note This page is extracted from the instruction manual ...
Page 20: ...20 11 Maintenance Note This page is extracted from the instruction manual ...
Page 33: ...33 ...