7. Technical Points
Dehumidifying
Defrosting
Coolant flow
Blow
Fan
Heat exchanger
(heat radiation)
φ
5
φ
6.35
φ
5
φ
6.35
Compressor
Heat exchanger
(cooling)
Intake
φ
6.35
Tube temperature
sensing thermistor
φ
6.35
Capillary tube
Capillary tube
φ
2.0
×φ
0.8
×φ
340
φ
5.0
×φ
4.0
φ
6.35
Humidity
sensor
Room
temperature
sensing thermistor
Solenoid
valve
(closed when
dehumidifying
and open
when
defrosting)
Note) This page is extracted from the instruction manual.
■
Coolant Circuit
■
Performance curve
9