10 - 10
10. CHARACTERISTICS
10.5 Inrush currents at power-on of main circuit and control circuit
The following table indicates the inrush currents (reference data) that will flow when the maximum permissible
voltage (200V class: 253VAC, 400V class: 528VAC) is applied at the power supply capacity of 2500kVA and
the wiring length of 1m (3.28ft).
Inrush Currents (A
0
-
p
)
Servo Amplifier
Main circuit power supply (L
1
, L
2
, L
3
)
Control circuit power supply (L
11
, L
21
)
MR-J3-10B1 to 40B1
38A (Attenuated to approx. 14A in 10ms)
MR-J3-10B to 60B
30A (Attenuated to approx. 5A in 10ms)
MR-J3-70B 100B
54A (Attenuated to approx. 12A in 10ms)
MR-J3-200B 350B
120A (Attenuated to approx. 12A in 20ms)
20 to 30A
(Attenuated to approx. 0A in 1 to 2ms)
MR-J3-500B
44A (Attenuated to approx. 20A in 20ms)
MR-J3-700B
88A (Attenuated to approx. 20A in 20ms)
MR-J3-11KB
MR-J3-15KB
MR-J3-22KB
235A (Attenuated to approx. 20A in 20ms)
30A (Attenuated to approx. 0A in 3ms)
MR-J3-60B4 100B4
100A (Attenuated to approx. 5A in 10ms)
MR-J3-200B4
120A (Attenuated to approx. 12A in 20ms)
40 to 50A
(Attenuated to approx. 0A in 2ms)
MR-J3-350B4 500B4
66A (Attenuated to approx. 10A in 20ms)
MR-J3-700B4
67A (Attenuated to approx. 34A in 20ms)
41A (Attenuated to approx. 0A in 3ms)
MR-J3-11KB4
MR-J3-15KB4
MR-J3-22KB4
325A (Attenuated to approx. 20A in 20ms)
45A (Attenuated to approx. 0A in 3ms)
Since large inrush currents flow in the power supplies, always use no-fuse breakers and magnetic contactors.
(Refer to section 11.12.)
When circuit protectors are used, it is recommended to use the inertia delay type that will not be tripped by an
inrush current.
Summary of Contents for Melservo MR-J3- 350B4
Page 15: ...A 14 MEMO ...
Page 21: ...6 MEMO ...
Page 107: ...3 52 3 SIGNALS AND WIRING MEMO ...
Page 171: ...7 16 7 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 181: ...8 10 8 TROUBLESHOOTING MEMO ...
Page 193: ...9 12 9 OUTLINE DRAWINGS MEMO ...
Page 297: ...12 6 12 ABSOLUTE POSITION DETECTION SYSTEM MEMO ...
Page 397: ...13 100 13 SERVO AMPLIFIERS WITH A LARGE CAPACITY 30k TO 55kW MEMO ...